Literature DB >> 12126386

The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments.

Gabriela Zelada1, Purificación Varela, Benjamín Martín, José G Bahíllo, Fernando Magán, Saem Ahn.   

Abstract

One of the biggest concerns when working with rotary endodontic instruments is that the instrument might break in the root canal thus compromising the treatment. This study evaluated the effect of rotational speed and the curvature of root canals on the breakage of ProFile rotary instruments to determine whether either causes an increase in instrument breakage. One hundred twenty root canals of extracted molars were divided into two groups according to whether the curvature of the canal was greater or lesser than 30 degrees. Three different rotational speeds (150, 250, and 350 rpm) were then used to carry out the instrumentation of the canals. The curvature of the canals would seem to be the most important factor that increases the risk of instrument breakage.

Mesh:

Year:  2002        PMID: 12126386     DOI: 10.1097/00004770-200207000-00014

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  16 in total

1.  Influence of file motion on cyclic fatigue of new nickel titanium instruments.

Authors:  Alessio Giansiracusa Rubini; Gianpaolo Sannino; Giancarlo Pongione; Luca Testarelli; Dina Al Sudani; Jeeraphat Jantarat; Massimo De Luca; Gianluca Gambarini
Journal:  Ann Stomatol (Roma)       Date:  2013-03-20

Review 2.  Endodontic Rotary Files, What Should an Endodontist Know?

Authors:  Ana-Belén Dablanca-Blanco; Pablo Castelo-Baz; Ramón Miguéns-Vila; Pablo Álvarez-Novoa; Benjamín Martín-Biedma
Journal:  Medicina (Kaunas)       Date:  2022-05-27       Impact factor: 2.948

3.  Cyclic fatigue resistance of D-RaCe, ProTaper, and Mtwo nickel-titanium retreatment instruments after immersion in sodium hypochlorite.

Authors:  Hüseyin Sinan Topçuoğlu; Kanşad Pala; Ahmet Aktı; Salih Düzgün; Gamze Topçuoğlu
Journal:  Clin Oral Investig       Date:  2015-09-30       Impact factor: 3.573

4.  Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study.

Authors:  Eugenio Pedullà; Gianluca Plotino; Nicola Maria Grande; Alfio Pappalardo; Ernesto Rapisarda
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

5.  Cyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro sem analysis.

Authors:  Pallavi Reddy Y; Kavita S; C V Subbarao
Journal:  J Clin Diagn Res       Date:  2014-02-03

6.  Evaluation of deformation and fracture rates for nickel-titanium rotary instruments according to the frequency of clinical use.

Authors:  Ayça Yılmaz; Sıtkı Selçuk Gökyay; Rüştü Dağlaroğlu; Işıl Karagöz Küçükay
Journal:  Eur Oral Res       Date:  2018-05-01

7.  Less extrusion debris during the retreatment of curved canals using twisted files with higher rotational speeds: an ex vivo study.

Authors:  Mengdong Liu; Shijiang Xiong; Fei Tan; Yi Liu
Journal:  BMC Oral Health       Date:  2017-01-16       Impact factor: 2.757

8.  Apical Microleakage in Root Canals Containing Broken Rotary Instruments.

Authors:  Mostafa Godiny; Reza Hatam; Atefeh Khavid; Shahryar Khanlari
Journal:  Iran Endod J       Date:  2017

9.  A Cone-Beam Computed Tomographic Study on Mandibular First Molars in a Chinese Subpopulation.

Authors:  Xin Zhang; Shijiang Xiong; Yue Ma; Ting Han; Xinyu Chen; Fang Wan; Yating Lu; Songhe Yan; Yan Wang
Journal:  PLoS One       Date:  2015-08-04       Impact factor: 3.240

10.  Failure of ProTaper rotary Ni-Ti instruments used by undergraduate students.

Authors:  Marc García-Font; Fernando Duran-Sindreu; Sergio Morello-Castro; Montserrat Mercade-Bellido; Rufino Bueno-Martínez; Miguel Roig-Cayón
Journal:  J Clin Exp Dent       Date:  2012-10-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.