Special article: evaluation of a novel noninvasive respiration monitor providing continuous measurement of minute ventilation in ambulatory subjects in a variety of clinical scenarios.

Christopher Voscopoulos1, Jordan Brayanov, Diane Ladd, Michael Lalli, Alexander Panasyuk, Jenny Freeman.   

Abstract

BACKGROUND: Currently there is no technology that noninvasively measures the adequacy of ventilation in nonintubated patients. A novel, noninvasive Respiratory Volume Monitor (RVM) has been developed to continuously measure and display minute ventilation (MV), tidal volume (TV), and respiratory rate (RR) in a variety of clinical settings. We demonstrate the RVM's accuracy and precision as compared with a standard spirometer under a variety of clinically relevant breathing patterns in nonintubated subjects.
METHODS: Thirty-one voluntary subjects completed the primary study. MV, TV, and RR measurements were collected from the RVM and spirometer simultaneously for each participant on day 1 and day 2 and analyzed to determine accuracy, precision, and bias for normal, fast, slow, irregular, and closed-glottis breathing.
RESULTS: Data demonstrated that RVM and spirometer measurements of MV and TV are equivalent in a wide range of ambulatory subjects with an average error <10% (95% confidence interval for accuracy <16%, precision <12%, and bias <11%). Repeated measures analysis of variance found no significant difference between spirometry and RVM individual measurements of MV, TV, and RR (P > 0.7), whereas a paired-difference equivalent test demonstrated, with 99% power, that both MV and TV measurements from the 2 devices are equivalent within ±15%.
CONCLUSIONS: This study demonstrates RVM's clinically relevant accuracy and precision in measuring MV, TV, and RR over a 24-hour period and during various breathing patterns.

Entities:  

Mesh:

Year:  2013        PMID: 23733842     DOI: 10.1213/ANE.0b013e3182918098

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  30 in total

1.  Breathing is good.

Authors:  Michael Ramsay
Journal:  J Clin Monit Comput       Date:  2015-04       Impact factor: 2.502

2.  An optimized method for estimating the tidal volume from intracardiac or body surface electrocardiographic signals: implications for estimating minute ventilation.

Authors:  Omid Sayadi; Eric H Weiss; Faisal M Merchant; Dheeraj Puppala; Antonis A Armoundas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2014-06-06       Impact factor: 4.733

3.  The Effect of Breathing Retraining Using Metronome-Based Acoustic Feedback on Exercise Endurance in COPD: A Randomized Trial.

Authors:  Eileen G Collins; Christine Jelinek; Susan O'Connell; Jolene Butler; Domenic Reda; Franco Laghi
Journal:  Lung       Date:  2019-02-09       Impact factor: 2.584

4.  Respiratory measurement using infrared thermography and respiratory volume monitor during sedation in patients undergoing endoscopic urologic procedures under spinal anesthesia.

Authors:  Jeongmin Kim; Jun Hwan Kwon; Eungjin Kim; Sun Kook Yoo; Cheung-Soo Shin
Journal:  J Clin Monit Comput       Date:  2018-11-14       Impact factor: 2.502

5.  Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations.

Authors:  Ala'aldeen Al-Halhouli; Loiy Al-Ghussain; Saleem El Bouri; Haipeng Liu; Dingchang Zheng
Journal:  J Clin Monit Comput       Date:  2020-02-22       Impact factor: 2.502

6.  Effect of Intravenous Acetaminophen on Postoperative Hypoxemia After Abdominal Surgery: The FACTOR Randomized Clinical Trial.

Authors:  Alparslan Turan; Hani Essber; Wael Saasouh; Karen Hovsepyan; Natalya Makarova; Sabry Ayad; Barak Cohen; Kurt Ruetzler; Loran Mounir Soliman; Kamal Maheshwari; Dongsheng Yang; Edward J Mascha; Wael Ali Sakr Esa; Herman Kessler; Conor P Delaney; Daniel I Sessler
Journal:  JAMA       Date:  2020-07-28       Impact factor: 56.272

7.  Non-invasive continuous respiratory monitoring using temperature-based sensors.

Authors:  Daniel E Hurtado; Angel Abusleme; Javier A P Chávez
Journal:  J Clin Monit Comput       Date:  2019-06-03       Impact factor: 2.502

8.  Ventilation monitoring during moderate sedation in GI patients.

Authors:  Thomas J Ebert; Austin H Middleton; Nikhil Makhija
Journal:  J Clin Monit Comput       Date:  2015-12-01       Impact factor: 2.502

9.  Fabrication and Evaluation of a Novel Non-Invasive Stretchable and Wearable Respiratory Rate Sensor Based on Silver Nanoparticles Using Inkjet Printing Technology.

Authors:  Ala'aldeen Al-Halhouli; Loiy Al-Ghussain; Saleem El Bouri; Haipeng Liu; Dingchang Zheng
Journal:  Polymers (Basel)       Date:  2019-09-18       Impact factor: 4.329

10.  The evaluation of a non-invasive respiratory volume monitor in surgical patients undergoing elective surgery with general anesthesia.

Authors:  Christopher J Voscopoulos; C Marshall MacNabb; Jordan Brayanov; Lizeng Qin; Jenny Freeman; Gary John Mullen; Diane Ladd; Edward George
Journal:  J Clin Monit Comput       Date:  2014-07-19       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.