The respiration rate (RR) is a key vital sign that links to adverse clinical outcomes and has various important uses. However, RR signals have been neglected in many clinical practices for several reasons and it is still difficult to develop low-cost RR sensors for accurate, automated, and continuous measurement. This study aims to fabricate, develop and evaluate a novel stretchable and wearable RR sensor that is low-cost and easy to use. The sensor is fabricated using the soft lithography technique of polydimethylsiloxane substrates (PDMS) for the stretchable sensor body and inkjet printing technology for creating the conductive circuit by depositing the silver nanoparticles on top of the PDMS substrates. The inkjet-printed (IJP) PDMS-based sensor was developed to detect the inductance fluctuations caused by respiratory volumetric changes. The output signal was processed in a Wheatstone bridge circuit to derive the RR. Six different patterns for a IJP PDMS-based sensor were carefully designed and tested. Their sustainability (maximum strain during measurement) and durability (the ability to go bear axial cyclic strains) were investigated and compared on an automated mechanical stretcher. Their repeatability (output of the sensor in repeated tests under identical condition) and reproducibility (output of different sensors with the same design under identical condition) were investigated using a respiratory simulator. The selected optimal design pattern from the simulator evaluation was used in the fabrication of the IJP PDMS-based sensor where the accuracy was inspected by attaching it to 37 healthy human subjects (aged between 19 and 34 years, seven females) and compared with the reference values from e-Health nasal sensor. Only one design survived the inspection procedures where design #6 (array consists of two horseshoe lines) indicated the best sustainability and durability, and went through the repeatability and reproducibility tests. Based on the best pattern, the developed sensor accurately measured the simulated RR with an error rate of 0.46 ± 0.66 beats per minute (BPM, mean ± SD). On human subjects, the IJP PDMS-based sensor and the reference e-Health sensor showed the same RR value, without any observable differences. The performance of the sensor was accurate with no apparent error compared with the reference sensor. Considering its low cost, good mechanical property, simplicity, and accuracy, the IJP PDMS-based sensor is a promising technique for continuous and wearable RR monitoring, especially under low-resource conditions.

Entities:  

Keywords:  PDMS; inkjet printing; respiratory rate; stretchable circuits; wearable sensors

Year:  2019        PMID: 31540494      PMCID: PMC6781180          DOI: 10.3390/polym11091518

Source DB:  PubMed          Journal:  Polymers (Basel)        ISSN: 2073-4360            Impact factor:   4.329


  36 in total

1.  A wearable respiration monitoring system based on digital respiratory inductive plethysmography.

Authors:  Dan Wu; Lei Wang; Yuan-Ting Zhang; Bang-Yu Huang; Bo Wang; Shao-Jie Lin; Xiao-Wen Xu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

2.  Clinical evaluation of a novel respiratory rate monitor.

Authors:  Peter J Lee
Journal:  J Clin Monit Comput       Date:  2015-04-22       Impact factor: 2.502

3.  Assessment of noninvasive acoustic respiration rate monitoring in patients admitted to an Emergency Department for drug or alcoholic poisoning.

Authors:  Youcef Guechi; Amélie Pichot; Denis Frasca; Fatima Rayeh-Pelardy; Jean-Yves Lardeur; Olivier Mimoz
Journal:  J Clin Monit Comput       Date:  2015-01-23       Impact factor: 2.502

4.  Airway resistance and lung volume in the newborn infant.

Authors:  G F Doershuk; L W Matthews
Journal:  Pediatr Res       Date:  1969-03       Impact factor: 3.756

5.  Inkjet-printed microelectrodes on PDMS as biosensors for functionalized microfluidic systems.

Authors:  Jianwei Wu; Ridong Wang; Haixia Yu; Guijun Li; Kexin Xu; Norman C Tien; Robert C Roberts; Dachao Li
Journal:  Lab Chip       Date:  2015-02-07       Impact factor: 6.799

6.  Special article: evaluation of a novel noninvasive respiration monitor providing continuous measurement of minute ventilation in ambulatory subjects in a variety of clinical scenarios.

Authors:  Christopher Voscopoulos; Jordan Brayanov; Diane Ladd; Michael Lalli; Alexander Panasyuk; Jenny Freeman
Journal:  Anesth Analg       Date:  2013-06-03       Impact factor: 5.108

7.  Respiration rate and volume measurements using wearable strain sensors.

Authors:  Michael Chu; Thao Nguyen; Vaibhav Pandey; Yongxiao Zhou; Hoang N Pham; Ronen Bar-Yoseph; Shlomit Radom-Aizik; Ramesh Jain; Dan M Cooper; Michelle Khine
Journal:  NPJ Digit Med       Date:  2019-02-13

8.  Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care.

Authors:  Ha Uk Chung; Bong Hoon Kim; Jong Yoon Lee; Jungyup Lee; Zhaoqian Xie; Erin M Ibler; KunHyuck Lee; Anthony Banks; Ji Yoon Jeong; Jongwon Kim; Christopher Ogle; Dominic Grande; Yongjoon Yu; Hokyung Jang; Pourya Assem; Dennis Ryu; Jean Won Kwak; Myeong Namkoong; Jun Bin Park; Yechan Lee; Do Hoon Kim; Arin Ryu; Jaeseok Jeong; Kevin You; Bowen Ji; Zhuangjian Liu; Qingze Huo; Xue Feng; Yujun Deng; Yeshou Xu; Kyung-In Jang; Jeonghyun Kim; Yihui Zhang; Roozbeh Ghaffari; Casey M Rand; Molly Schau; Aaron Hamvas; Debra E Weese-Mayer; Yonggang Huang; Seung Min Lee; Chi Hwan Lee; Naresh R Shanbhag; Amy S Paller; Shuai Xu; John A Rogers
Journal:  Science       Date:  2019-03-01       Impact factor: 47.728

Review 9.  Silver nanoparticle ink technology: state of the art.

Authors:  Krishna Rajan; Ignazio Roppolo; Annalisa Chiappone; Sergio Bocchini; Denis Perrone; Alessandro Chiolerio
Journal:  Nanotechnol Sci Appl       Date:  2016-01-11

10.  Experimental Characterization of Inkjet-Printed Stretchable Circuits for Wearable Sensor Applications.

Authors:  Jumana Abu-Khalaf; Razan Saraireh; Saleh Eisa; Ala'aldeen Al-Halhouli
Journal:  Sensors (Basel)       Date:  2018-10-16       Impact factor: 3.576

View more
  8 in total

Review 1.  Monitoring Symptoms of Infectious Diseases: Perspectives for Printed Wearable Sensors.

Authors:  Ala'aldeen Al-Halhouli; Ahmed Albagdady; Ja'far Alawadi; Mahmoud Abu Abeeleh
Journal:  Micromachines (Basel)       Date:  2021-05-27       Impact factor: 2.891

2.  Continuous Journey Toward Polymer Applications.

Authors:  Wei Min Huang
Journal:  Polymers (Basel)       Date:  2020-02-04       Impact factor: 4.329

3.  Optimization of Geometry Parameters of Inkjet-Printed Silver Nanoparticle Traces on PDMS Substrates Using Response Surface Methodology.

Authors:  Jumana Abu-Khalaf; Loiy Al-Ghussain; Ahmad Nadi; Razan Saraireh; Abdulrahman Rabayah; Safwan Altarazi; Ala'aldeen Al-Halhouli
Journal:  Materials (Basel)       Date:  2019-10-12       Impact factor: 3.623

4.  Breathing Signature as Vitality Score Index Created by Exercises of Qigong: Implications of Artificial Intelligence Tools Used in Traditional Chinese Medicine.

Authors:  Junjie Zhang; Qingning Su; William G Loudon; Katherine L Lee; Jane Luo; Brent A Dethlefs; Shengwen Calvin Li
Journal:  J Funct Morphol Kinesiol       Date:  2019-12-03

Review 5.  The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise.

Authors:  Andrea Nicolò; Carlo Massaroni; Emiliano Schena; Massimo Sacchetti
Journal:  Sensors (Basel)       Date:  2020-11-09       Impact factor: 3.576

Review 6.  Remote Healthcare for Elderly People Using Wearables: A Review.

Authors:  José Oscar Olmedo-Aguirre; Josimar Reyes-Campos; Giner Alor-Hernández; Isaac Machorro-Cano; Lisbeth Rodríguez-Mazahua; José Luis Sánchez-Cervantes
Journal:  Biosensors (Basel)       Date:  2022-01-27

7.  Beyond Chemistry: Tailoring Stiffness and Microarchitecture to Engineer Highly Sensitive Biphasic Elastomeric Piezoresistive Sensors.

Authors:  Matteo Solazzo; Linette Hartzell; Ciara O'Farrell; Michael G Monaghan
Journal:  ACS Appl Mater Interfaces       Date:  2022-04-22       Impact factor: 10.383

8.  Accurate Spirometry with Integrated Barometric Sensors in Face-Worn Garments.

Authors:  Bo Zhou; Alejandro Baucells Costa; Paul Lukowicz
Journal:  Sensors (Basel)       Date:  2020-07-29       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.