Literature DB >> 31161533

Non-invasive continuous respiratory monitoring using temperature-based sensors.

Daniel E Hurtado1, Angel Abusleme2, Javier A P Chávez3.   

Abstract

Respiratory rate (RR) is a key vital sign that has been traditionally employed in the clinical assessment of patients and in the prevention of respiratory compromise. Despite its relevance, current practice for monitoring RR in non-intubated patients strongly relies on visual counting, which delivers an intermittent and error-prone assessment of the respiratory status. Here, we present a novel non-invasive respiratory monitor that continuously measures the RR in human subjects. The respiratory activity of the user is inferred by sensing the thermal transfer between the breathing airflow and a temperature sensor placed between the nose and the mouth. The performance of the respiratory monitor is assessed through respiratory experiments performed on healthy subjects. Under spontaneous breathing, the mean RR difference between our respiratory monitor and visual counting was 0.4 breaths per minute (BPM), with a 95% confidence interval equal to [- 0.5, 1.3] BPM. The robustness of the respiratory sensor to the position is assessed by studying the signal-to-noise ratio in different locations on the upper lip, displaying a markedly better performance than traditional thermal sensors used for respiratory airflow measurements.

Entities:  

Keywords:  Monitoring; Respiration; Thermal sensors

Mesh:

Year:  2019        PMID: 31161533     DOI: 10.1007/s10877-019-00329-5

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  21 in total

Review 1.  Critical review of non-invasive respiratory monitoring in medical care.

Authors:  M Folke; L Cernerud; M Ekström; B Hök
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

2.  A novel ultra-wideband 80 GHz FMCW radar system for contactless monitoring of vital signs.

Authors:  Siying Wang; Antje Pohl; Timo Jaeschke; Michael Czaplik; Marcus Köny; Steffen Leonhardt; Nils Pohl
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2015

3.  A semi-automatic method for peak and valley detection in free-breathing respiratory waveforms.

Authors:  Wei Lu; Michelle M Nystrom; Parag J Parikh; David R Fooshee; James P Hubenschmidt; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

4.  Why don't nurses monitor the respiratory rates of patients?

Authors:  Jacqueline Hogan
Journal:  Br J Nurs       Date:  2006 May 11-24

Review 5.  Respiratory rate: the neglected vital sign.

Authors:  Michelle A Cretikos; Rinaldo Bellomo; Ken Hillman; Jack Chen; Simon Finfer; Arthas Flabouris
Journal:  Med J Aust       Date:  2008-06-02       Impact factor: 7.738

6.  Postoperative opioid-induced respiratory depression: a closed claims analysis.

Authors:  Lorri A Lee; Robert A Caplan; Linda S Stephens; Karen L Posner; Gregory W Terman; Terri Voepel-Lewis; Karen B Domino
Journal:  Anesthesiology       Date:  2015-03       Impact factor: 7.892

Review 7.  Incidence, Reversal, and Prevention of Opioid-induced Respiratory Depression.

Authors:  Albert Dahan; Leon Aarts; Terry W Smith
Journal:  Anesthesiology       Date:  2010-01       Impact factor: 7.892

8.  APACHE-acute physiology and chronic health evaluation: a physiologically based classification system.

Authors:  W A Knaus; J E Zimmerman; D P Wagner; E A Draper; D E Lawrence
Journal:  Crit Care Med       Date:  1981-08       Impact factor: 7.598

9.  Special article: evaluation of a novel noninvasive respiration monitor providing continuous measurement of minute ventilation in ambulatory subjects in a variety of clinical scenarios.

Authors:  Christopher Voscopoulos; Jordan Brayanov; Diane Ladd; Michael Lalli; Alexander Panasyuk; Jenny Freeman
Journal:  Anesth Analg       Date:  2013-06-03       Impact factor: 5.108

10.  Low minute ventilation episodes during anesthesia recovery following intraperitoneal surgery as detected by a non-invasive respiratory volume monitor.

Authors:  Alexandre N Cavalcante; Yvette N Martin; Juraj Sprung; Jasmin Imsirovic; Toby N Weingarten
Journal:  J Clin Monit Comput       Date:  2017-12-20       Impact factor: 2.502

View more
  3 in total

1.  Polymeric piezoresistive airflow sensor to monitor respiratory patterns.

Authors:  Sajad Abolpour Moshizi; Abolfazl Abedi; Majid Sanaeepur; Christopher J Pastras; Zhao Jun Han; Shuying Wu; Mohsen Asadnia
Journal:  J R Soc Interface       Date:  2021-12-08       Impact factor: 4.118

2.  Assessment of neonatal respiratory rate variability.

Authors:  Jesse Coleman; Amy Sarah Ginsburg; William M Macharia; Roseline Ochieng; Dorothy Chomba; Guohai Zhou; Dustin Dunsmuir; Walter Karlen; J Mark Ansermino
Journal:  J Clin Monit Comput       Date:  2022-03-25       Impact factor: 2.502

3.  Insights into postoperative respiration by using continuous wireless monitoring of respiratory rate on the postoperative ward: a cohort study.

Authors:  Linda M Posthuma; Maarten J Visscher; Philipp B Lirk; Els J M Nieveen van Dijkum; Markus W Hollmann; Benedikt Preckel
Journal:  J Clin Monit Comput       Date:  2019-11-13       Impact factor: 2.502

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.