Literature DB >> 23724212

Comparison of the amount of fluoride release from nanofilled resin modified glass ionomer, conventional and resin modified glass ionomer cements.

Sumitha Upadhyay1, Arathi Rao, Ramya Shenoy.   

Abstract

OBJECTIVE: To investigate and compare the amount of fluoride release of conventional, resin modified and nanofilled resin modified glass ionomer cements.
MATERIALS AND METHODS: Tablets of glass-ionomer cements were immersed in deionized water and incubated at 37°C. After 1, 2, 7, 15 and 30 days, fluoride ion was measured under normal atmospheric conditions by fluoride ion selective electrode. Buffer (TISAB II) was used to decomplex the fluoride ion and to provide a constant background ionic strength and to maintain the pH of water between 5.0 and 5.5 as the fluoride electrode is sensitive to changes in pH. Statistical evaluation was carried out by one way ANOVA (Analysis of Variance) using SPSS 11.0. The significance level was set at p< 0.05.
RESULTS: The release of fluoride was highest on day 1 and there was a sudden fall on day 2 in all three groups. Initially fluoride release from conven-tional glass-ionomer cement was highest compared to the other two glass-ionomer cements, but the amount drastically reduced over the period. Although the amount of fluoride release was less than both the resin modified and nanofilled resin modified glass-ionomer cement, the release was sustained consistently for 30 days.
CONCLUSION: The cumulative fluoride release of nanofilled resin modified glass ionomer cement was very less compared to the conventional and resin modified glass ionomer cements and Nanofilled resin modified glass ionomer cement released less but steady fluoride as compared to other resin modified glass ionomer cements.

Entities:  

Keywords:  Fluoride; Nano-filled Glass Ionomer; Resin- Modified Glass Ionomer

Year:  2013        PMID: 23724212      PMCID: PMC3666073     

Source DB:  PubMed          Journal:  J Dent (Tehran)        ISSN: 1735-2150


INTRODUCTION

The oral cavity is constantly exposed to demineralization and remineralization. Demineralization results when the pH falls due to release of acids produced by the action of plaque bacteria in the presence of dietary carbohydrates. Remineralization is seen conversely, when the pH rises with the deposition of calcium and phosphate ions. Continuous demineralization results in the loss of tooth structure. Therefore, the best strategy for caries management is focus on the methods of improving the remineralizing process. Various materials are available that exclusively deliver remineralizing agents. Incorporating fluoride, a remineralizing agent in a restorative material, definitely reduces the occurrence of secondary caries. Fluoride released from restorative materials has an effective zone of about 1 mm from the margin of glass ionomer restorations [2]. Release of fluoride from restorative materials also maintains the fluoride level in the oral fluid. After placement of glass-ionomer restorations, salivary fluoride concentration is approximately 0.3 ppm immediately after and remains up to 0.04 ppm after 1 year [3]. The content of fluoride in glass ionomer restorative materials is about 10 to 23% [4] and a direct relationship was detected between the presence of fluoride in the cement and the amount released [5]. Development in the field of glass-ionomer cement has led to the introduction of nanoionomer which is a nanofilled resin-modified glass-ionomer cement. The present study compared fluoride release among nanoionomer, conventional and resin-modified glass-ionomer cements.

MATERIALS AND METHODS

The present study was performed on conventional glass ionomer (GC Corporation Tokyo, Japan), resin-modified glass-ionomer and nanoionomer (Ketac™ N100). Conventional glass ionomer cements (GlC) were first introduced in 1972 by Wilson and Kent. They are derived from aqueous polyalkenoic acid such as polyacrylic acid and a glass component that is usually a fluoroaluminosilicate. They are dispensed as powder and liquid which are mixed together to initiate an acid-base reaction. Resin modified glass ionomer cements are conventional glass ionomer cements with the addition of HEMA. (Hydroxyethylmethacrylate) They undergo both an acid-base ionomer reaction as well as curing by photo-initiation and self-cure of methacrylate carbon double bonds. Ketac™ N100 is a two-part paste system that makes the dispensing and mixing easier and faster. “Paste A is resin-based and contains fluoroaluminosilicate glass, silane-treated silica and zirconia silica nanofillers, methacrylate and dimethacrylate resins, and photoinitiators. Paste B is water-based and contains polyalkenoic acid copolymer, silane-treated zirconia silica nanoclusters, silane-treated silica nanofiller, and hydroxymethylmethacrylate (HEMA). Ketac™ Nano Primer contains water, HEMA, polyalkenoic acid copolymer, and photoinitiators” [6]. Manufacturers claim that the presence of nanofillers in this material has improved esthetics, wear resistance and still provides the benefits of fluoride release [7]. The purpose of the present study was to compare the fluoride release among conventional, resin-modified and nanofilled glass ionomer cements.

Sample preparation

Tablets of three glass ionomer cements (10 for each group) were used for the study. They were prepared from 9×2 mm sized cylindrical brass moulds (Fig 1). A thick transparent sheet was first secured on a flat surface. This provided the base for the mould. Glass ionomer cements were then hand mixed according to the manufacturer’s instructions.
Fig 1

Cylindrical brass moulds

The mixed material was placed into the mould and covered with a mylar strip. A dental floss was incorporated into the tablets during fabrication to allow suspension into the test medium (Fig 2).
Fig 2

Dental floss incorporated into the tablets

A glass slide was then placed over the mould. Hand pressure was applied to extrude excess material and to ensure uniform and void free specimen discs.Conventional glass ionomer cement was set in the mould. The other two glass ionomer cements were light cured for 20 seconds from the top. Then the glass slide was removed and cured from below for 20 secs. The set discs were gently pushed out of the moulds.Each disc specimen was immersed in airtight polyethylene bottle containing 20ml of deionized water and incubated at 37°C and stored for 24 hours.

Determination of fluoride ion release

Fluoride ion measurement was performed at the end of the first, second, seventh, fifteenth and thirtieth day under normal atmospheric conditions by fluoride ion selective electrode (Fig 3) connected to an ion selective electrode meter (ORION 940900) after calibration with 2.5, 5 and 10 part per million of standard fluoride solution.
Fig 3

Fluoride ion selective electrode connected to an ion selective electrode meter

At the end of the first day, each specimen was removed from the bottle, washed with 1ml of deionized water, dried with absorbent paper and then restored in a new 20 ml of fresh deionized water and reincubated. 20 ml of the previous solution from the plastic bottle and 1ml used for washing the disc was mixed with an equal amount of total ionic strength adjustment buffer (TISAB II). This was then transferred to a plastic vial into which a magnetic stirrer was placed. The electrode was dipped into the solution and fluoride concentration was recorded in parts per million. (TISAB II) is used to decomplex the fluoride ion, to provide a constant background ionic strength and to hold the pH of water between 5.0 and 5.5 as the fluoride electrode is sensitive to changes in pH [4]. TISAB II is prepared by adding 4 gms of CDTA (cyclohexylenedinitrilo tetra acetate) to 57 ml of glacial acetic acid and 58 gms of sodium chloride and dissolving this in 500 ml of double distilled water. The pH of the solution is adjusted between 5.3 and 5.5 by slowly adding 130 ml of 6N sodium hydroxide. Each constituent plays an important role in controlling the ionic strength and pH of the analytic solution that may otherwise cause error and inaccuracy. Similar steps were followed for the 2nd, 7th, 15th and 30th day and the electrode was recalibrated with 2.5, 5 and 10 ppm of standard fluoride solution for each day.

Statistical analysis

Statistical evaluation was carried out using one way ANOVA (Analysis of Variance) using SPSS 11.0 for Windows (SPSS Inc., Ill, Chicago, USA) at the level of significance of p< 0.05.

RESULT

In this study, we compared fluoride release among three glass ionomer cements. The means and standard deviations of fluoride release (in ppm) of each group on different days are demonstrated in Table 1 and Table 2 gives the intergroup comparison of fluoride release.
Table 1

Means and Standard Deviations of Fluoride Release (in ppm) by Tested Glass Ionomer Cements

DayConventional Glass IonomerResin modified Glass IonomerNanoionomer
13.38 ± 0.422.88 ±0.491.76 ±0.23
20.88 ± 0.180.77 ±0.190.65 ±0.07
72.51± 0.372.06±0.181.74 ±0.29
151.42±0.162.02 ±0.411.27±0.14
301.85±0.12.19±0.151.36±0.15

Level of Significance: <0.05

Table 2

Intergroup Comparison of Fluoride Release

Group B (Resin Modified GIC)Group C (Nanofilled Resin Modified GIC)

1st Day2nd Day7th Day15th Day30th Day1st Day2nd Day7th Day15th Day30th Day
Group A (Conventional GIC)p=0.024p=0.247p=0.005p=0000.p=0.005p=0.000p=0.007p=0.000p=0.370p=0.000
Group Bp=0.000p=0.220p=0.048p=0.000p=0.000
Fluoride release was highest on day 1 and there was a sudden fall on day 2 in all three groups. Fluoride release later increased up to day seven following which there was a gradual decrease (Fig 4).
Fig 4

Fluoride release from three glass ionomer cements on different days

On the first day, fluoride release from conventional glass ionomer cement was highest compared to the other two glass ionomer cements (p< 0.05), but the amount of release of fluoride drastically reduced over the period. On the contrary, the resin modified and nanoionomer materials released less amounts on the first day, but they continued to release fluoride consistently for 30 days.For evaluation of the cumulative fluoride release, both the conventional and resin modified glass ionomer cements released significantly higher fluoride than the nanoionomer cement (p< 0.05).

DISCUSSION

Fluoride release from a GIC is a complex process and the released amount depends on various factors. Intrinsic factors that may affect fluoride release include formulation, solubility or porosity of the material [8]. The lower the pH, the higher the fluoride release [10]. The higher the environmental temperature, the greater the fluoride release11. Other factors such as an improper powder liquid ratio, improper mixing and improper curing also affects fluoride release [12-14]. El Mallakh and Sarkar NK [9] found that fluoride release of glass ionomer cement was higher in distilled water as compared to artificial saliva. pH of the media also affects the fluoride release. All glass ionomer cements evaluated in this study released measurable amounts of fluoride which was highest on the first day after which the release reached to a low steady level. This is a normal feature of glass ionomer cements and is called as “Burst Effect” [15-17]. Perrin et al. [18] reported that the greatest release of fluoride from glass ionomer occurred on the first day followed by a sharp decrease on the second day, and gradually diminished over 3 weeks to a low-level, long-term release. The burst effect is probably associated with the release of fluoride which is loosely bound in the glass ionomer cement and originates from the initial acid-base reaction between the glass and polyalkenoic acid [19]. The later gradual release results from a balance between erosive leaching of glass particles in the bulk of the cement and diffusion of the leached fluoride through the cement matrix. The burst effect of fluoride release is important for remineralization as well as for the reduction of viability of bacteria that may have been left in the inner carious dentine [20]. According to De Araujo FB et al. [21] and Diaz Arnold et al. [22] resin modified glass ionomer cements release less fluoride initially compared to the conventional glass ionomer cement. In the present study, cumulative fluoride release from conventional and resin modified glass ionomer cements were almost similar. This was in agreement with the study by Mitra SB [23]. In accordance with the present study Paschoal et al .[24] also observed that nanoparticulated glass ionomer cement releases less but steady release of fluoride as compared to other resin modified glass ionomer cements. Fluoride reduces the translucency of the material and thus the manufacturers may have compromised on the initial amount of fluoride added to improve the esthetic property of the material. This may be the reason for low release of fluoride by the nanoionomer cement. The minimum amount of fluoride that is necessary for preventing or arresting a carious lesion has not been well established [25]. Thus it is difficult to conclude whether the lesser amount of fluoride released by nanoionomer may be adequate or not as an anticaries agent. A long term clinical trial would be a step further in establishing the anticaries effect of nanoionomer. The cumulative fluoride release of nanofilled resin modified glass ionomer cement was very less compared to the conventional and resin modified glass ionomer cements which were almost similar to each other. Nanofilled resin modified glass ionomer cement released less but steady fluoride as compared to other resin modified glass ionomer cements.
  21 in total

1.  In vitro fluoride release from a light-cured glass-ionomer liner/base.

Authors:  S B Mitra
Journal:  J Dent Res       Date:  1991-01       Impact factor: 6.116

2.  Determination of fluoride release from light-cured glass-ionomers and a fluoridated composite resin from the viewpoint of curing time.

Authors:  H Ulukapi; Y Benderli; M Soyman
Journal:  J Oral Rehabil       Date:  1996-03       Impact factor: 3.837

3.  Inhibitive effect of a resin-modified glass ionomer cement on remote enamel artificial caries.

Authors:  D Tantbirojn; W H Douglas; A Versluis
Journal:  Caries Res       Date:  1997       Impact factor: 4.056

4.  Fluoride release from fluoride-containing materials.

Authors:  F B de Araujo; F García-Godoy; J A Cury; E N Conceição
Journal:  Oper Dent       Date:  1996 Sep-Oct       Impact factor: 2.440

5.  Fluoride release from glass-ionomer cements, compomers and resin composites.

Authors:  G Vermeersch; G Leloup; J Vreven
Journal:  J Oral Rehabil       Date:  2001-01       Impact factor: 3.837

6.  Fluoride release from some dental materials in different solutions.

Authors:  A S Carvalho; J A Cury
Journal:  Oper Dent       Date:  1999 Jan-Feb       Impact factor: 2.440

7.  Fluoride release from restorative materials and its effects on dentin demineralization.

Authors:  C Francci; T G Deaton; R R Arnold; E J Swift; J Perdigão; J W Bawden
Journal:  J Dent Res       Date:  1999-10       Impact factor: 6.116

8.  Fluoride release from three glass ionomer materials and the effects of varnishing with or without finishing.

Authors:  C McKnight-Hanes; G M Whitford
Journal:  Caries Res       Date:  1992       Impact factor: 4.056

9.  Fluoride release process of (resin-modified) glass-ionomer cements versus (polyacid-modified) composite resins.

Authors:  R M Verbeeck; E A De Maeyer; L A Marks; R J De Moor; A M De Witte; L M Trimpeneers
Journal:  Biomaterials       Date:  1998-03       Impact factor: 12.479

10.  Fluoride content and recharge ability of five glassionomer dental materials.

Authors:  Dejan Lj Markovic; Bojan B Petrovic; Tamara O Peric
Journal:  BMC Oral Health       Date:  2008-07-28       Impact factor: 2.757

View more
  7 in total

1.  Evaluation of Ion Release from Four Dental Sealants.

Authors:  Liang Chen; Su-Juan Zeng; Yu-Hong Li; Min-Quan Du
Journal:  Curr Med Sci       Date:  2018-06-22

2.  Antibacterial Activity and Fluoride Release of Glass-Ionomer Cement, Compomer and Zirconia Reinforced Glass-Ionomer Cement.

Authors:  Sonia Tiwari; Mallikarjuna Kenchappa; Deepak Bhayya; Shilpi Gupta; Sudhanshu Saxena; Saurabh Satyarth; Aishwarya Singh; Manoj Gupta
Journal:  J Clin Diagn Res       Date:  2016-04-01

Review 3.  Factors influencing fluoride release in atraumatic restorative treatment (ART) materials: A review.

Authors:  P Divya Kumari; Shahnawaz Khijmatgar; Avidyuti Chowdhury; Edward Lynch; Chitta R Chowdhury
Journal:  J Oral Biol Craniofac Res       Date:  2019-06-27

4.  Do conventional glass ionomer cements release more fluoride than resin-modified glass ionomer cements?

Authors:  Maria Fernanda Costa Cabral; Roberto Luiz de Menezes Martinho; Manoel Valcácio Guedes-Neto; Maria Augusta Bessa Rebelo; Danielson Guedes Pontes; Flávia Cohen-Carneiro
Journal:  Restor Dent Endod       Date:  2015-05-26

5.  Energy dispersive X-ray microanalysis, fluoride release, and antimicrobial properties of glass ionomer cements indicated for atraumatic restorative treatment.

Authors:  Sudhanshu Saxena; Sonia Tiwari
Journal:  J Int Soc Prev Community Dent       Date:  2016 Jul-Aug

6.  Fluoride release from two types of fluoride-containing orthodontic adhesives: Conventional versus resin-modified glass ionomer cements-An in vitro study.

Authors:  Yasemin Dziuk; Sachin Chhatwani; Stephan C Möhlhenrich; Sabrina Tulka; Ella A Naumova; Gholamreza Danesh
Journal:  PLoS One       Date:  2021-02-26       Impact factor: 3.240

7.  Effect of zinc oxide nanoparticles on physical and antimicrobial properties of resin-modified glass ionomer cement.

Authors:  Zahra Malekhoseini; Mohammad Bagher Rezvani; Mohammad Niakan; Mohammad Atai; Mahshid Mohammadi Bassir; Hamid Safar Alizade; Saba Siabani
Journal:  Dent Res J (Isfahan)       Date:  2021-09-25
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.