Robot-assisted intraocular surgery: development of the IRISS and feasibility studies in an animal model.

E Rahimy1, J Wilson, T-C Tsao, S Schwartz, J-P Hubschman.   

Abstract

PURPOSE: The aim of this study is to develop a novel robotic surgical platform, the IRISS (Intraocular Robotic Interventional and Surgical System), capable of performing both anterior and posterior segment intraocular surgery, and assess its performance in terms of range of motion, speed of motion, accuracy, and overall capacities. PATIENTS AND METHODS: To test the feasibility of performing 'bimanual' intraocular surgical tasks using the IRISS, we defined four steps out of typical anterior (phacoemulsification) and posterior (pars plana vitrectomy (PPV)) segment surgery. Selected phacoemulsification steps included construction of a continuous curvilinear capsulorhexis and cortex removal in infusion-aspiration (I/A) mode. Vitrectomy steps consisted of performing a core PPV, followed by aspiration of the posterior hyaloid with the vitreous cutter to induce a posterior vitreous detachment (PVD) assisted with triamcinolone, and simulation of the microcannulation of a temporal retinal vein. For each evaluation, the duration and the successful completion of the task with or without complications or involuntary events was assessed.
RESULTS: Intraocular procedures were successfully performed on 16 porcine eyes. Four eyes underwent creation of a round, curvilinear anterior capsulorhexis without radialization. Four eyes had I/A of lens cortical material completed without posterior capsular tear. Four eyes completed 23-gauge PPV followed by successful PVD induction without any complications. Finally, simulation of microcannulation of a temporal retinal vein was successfully achieved in four eyes without any retinal tears/perforations noted.
CONCLUSION: Robotic-assisted intraocular surgery with the IRISS may be technically feasible in humans. Further studies are pending to improve this particular surgical platform.

Entities:  

Mesh:

Year:  2013        PMID: 23722720      PMCID: PMC3740307          DOI: 10.1038/eye.2013.105

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  27 in total

1.  Transatlantic robot-assisted telesurgery.

Authors:  J Marescaux; J Leroy; M Gagner; F Rubino; D Mutter; M Vix; S E Butner; M K Smith
Journal:  Nature       Date:  2001-09-27       Impact factor: 49.962

2.  Assessment of a hexapod surgical system for robotic micro-macro manipulations in ocular surgery.

Authors:  Jean-Louis Bourges; Jean-Pierre Hubschman; Jason Wilson; Stephen Prince; Tsu-Chin Tsao; Steven Schwartz
Journal:  Ophthalmic Res       Date:  2010-11-27       Impact factor: 2.892

3.  Robotic ocular surgery.

Authors:  A Tsirbas; C Mango; E Dutson
Journal:  Br J Ophthalmol       Date:  2006-10-04       Impact factor: 4.638

4.  'The Microhand': a new concept of micro-forceps for ocular robotic surgery.

Authors:  J-P Hubschman; J-L Bourges; W Choi; A Mozayan; A Tsirbas; C-J Kim; S-D Schwartz
Journal:  Eye (Lond)       Date:  2009-03-20       Impact factor: 3.775

5.  Robot-assisted vitreoretinal surgery: development of a prototype and feasibility studies in an animal model.

Authors:  Takashi Ueta; Yoshiharu Yamaguchi; Yoshihiro Shirakawa; Taiga Nakano; Ryuichi Ideta; Yasuo Noda; Akio Morita; Ryo Mochizuki; Naohiko Sugita; Mamoru Mitsuishi; Yasuhiro Tamaki
Journal:  Ophthalmology       Date:  2009-07-09       Impact factor: 12.079

6.  Automatic online spectral calibration of Fourier-domain OCT for robotic surgery.

Authors:  Xuan Liu; Marcin Balicki; Russell H Taylor; Jin U Kang
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-02-21

7.  Computer-enhanced telemanipulation in mitral valve repair: preliminary experience in Canada with the da Vinci robotic system.

Authors:  R Scott McClure; Bob Kiaii; Richard J Novick; Reiza Rayman; Stuart Swinamer; Kojiro Kodera; Alan H Menkis
Journal:  Can J Surg       Date:  2006-06       Impact factor: 2.089

8.  Laparoscopic hysterectomy using a computer-enhanced surgical robot.

Authors:  C Diaz-Arrastia; C Jurnalov; G Gomez; C Townsend
Journal:  Surg Endosc       Date:  2002-06-27       Impact factor: 4.584

9.  Towards automatic calibration of Fourier-Domain OCT for robot-assisted vitreoretinal surgery.

Authors:  Xuan Liu; Marcin Balicki; Russell H Taylor; Jin U Kang
Journal:  Opt Express       Date:  2010-11-08       Impact factor: 3.894

10.  Emerging role of robotics in urology.

Authors:  Rajeev Kumar; Ashok K Hemal
Journal:  J Minim Access Surg       Date:  2005-10       Impact factor: 1.407

View more
  21 in total

1.  Using smartphone-delivered stereoscopic vision in microsurgery: a feasibility study.

Authors:  Derek Kwun-Hong Ho
Journal:  Eye (Lond)       Date:  2019-02-12       Impact factor: 3.775

2.  Robotic posterior capsule polishing by optical coherence tomography image guidance.

Authors:  Matthew J Gerber; Jean-Pierre Hubschman; Tsu-Chin Tsao
Journal:  Int J Med Robot       Date:  2021-03-08       Impact factor: 2.547

3.  Semiautomated optical coherence tomography-guided robotic surgery for porcine lens removal.

Authors:  Cheng-Wei Chen; Anibal Andrés Francone; Matthew J Gerber; Yu-Hsiu Lee; Andrea Govetto; Tsu-Chin Tsao; Jean-Pierre Hubschman
Journal:  J Cataract Refract Surg       Date:  2019-11       Impact factor: 3.351

4.  Techniques for robot-aided intraocular surgery using monocular vision.

Authors:  Sungwook Yang; Joseph N Martel; Louis A Lobes; Cameron N Riviere
Journal:  Int J Rob Res       Date:  2018-07-13       Impact factor: 4.703

Review 5.  Robotic Vitreoretinal Surgery.

Authors:  Roomasa Channa; Iulian Iordachita; James T Handa
Journal:  Retina       Date:  2017-07       Impact factor: 4.256

6.  Automatic Light Pipe Actuating System for Bimanual Robot-Assisted Retinal Surgery.

Authors:  Changyan He; Emily Yang; Niravkumar Patel; Ali Ebrahimi; Mahya Shahbazi; Peter Gehlbach; Iulian Iordachita
Journal:  IEEE ASME Trans Mechatron       Date:  2020-05-22       Impact factor: 5.303

7.  Hybrid position/force control of an active handheld micromanipulator for membrane peeling.

Authors:  Trent S Wells; Sungwook Yang; Robert A MacLachlan; Louis A Lobes; Joseph N Martel; Cameron N Riviere
Journal:  Int J Med Robot       Date:  2015-05-11       Impact factor: 2.547

8.  Cooperative robot assistant for vitreoretinal microsurgery: development of the RVRMS and feasibility studies in an animal model.

Authors:  Yi-Qi Chen; Ji-Wei Tao; Ling-Ya Su; Liang Li; Shi-Xin Zhao; Yang Yang; Li-Jun Shen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-04-08       Impact factor: 3.117

9.  Toward Safe Retinal Microsurgery: Development and Evaluation of an RNN-Based Active Interventional Control Framework.

Authors:  Changyan He; Niravkumar Patel; Mahya Shahbazi; Yang Yang; Peter Gehlbach; Marin Kobilarov; Iulian Iordachita
Journal:  IEEE Trans Biomed Eng       Date:  2019-07-01       Impact factor: 4.538

10.  Optical Coherence Tomography Guided Robotic Needle Insertion for Deep Anterior Lamellar Keratoplasty.

Authors:  Mark Draelos; Gao Tang; Brenton Keller; Anthony Kuo; Kris Hauser; Joseph A Izatt
Journal:  IEEE Trans Biomed Eng       Date:  2019-11-20       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.