Cheng-Wei Chen1, Anibal Andrés Francone2, Matthew J Gerber3, Yu-Hsiu Lee4, Andrea Govetto5, Tsu-Chin Tsao4, Jean-Pierre Hubschman2. 1. Electrical Engineering, National Taiwan University. 2. Stein Eye Institute, University of California, Los Angeles, USA. 3. Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, USA. Electronic address: gerber211@ucla.edu. 4. Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, USA. 5. Oftalmico Hospital, ASST-Fatebenefratelli-Sacco, Milan, Italy.
Abstract
PURPOSE: To evaluate semiautomated surgical lens extraction procedures using the optical coherence tomography (OCT)-integrated Intraocular Robotic Interventional Surgical System. SETTING: Stein Eye Institute and Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, USA. DESIGN: Experimental study. METHODS: Semiautomated lens extraction was performed on postmortem pig eyes using a robotic platform integrated with an OCT imaging system. Lens extraction was performed using a series of automated steps including robot-to-eye alignment, irrigation/aspiration (I/A) handpiece insertion, anatomic modeling, surgical path planning, and I/A handpiece navigation. Intraoperative surgical supervision and human intervention were enabled by real-time OCT image feedback to the surgeon via a graphical user interface. Manual preparation of the pig-eye models, including the corneal incision and capsulorhexis, was performed by a trained cataract surgeon before the semiautomated lens extraction procedures. A scoring system was used to assess surgical complications in a postoperative evaluation. RESULTS: Complete lens extraction was achieved in 25 of 30 eyes. In the remaining 5 eyes, small lens pieces (≤1.0 mm3) were detected near the lens equator, where transpupillary OCT could not image. No posterior capsule rupture or corneal leakage occurred. The mean surgical duration was 277 seconds ± 42 (SD). Based on a 3-point scale (0 = no damage), damage to the iris was 0.33 ± 0.20, damage to the cornea was 1.47 ± 0.20 (due to tissue dehydration), and stress at the incision was 0.97 ± 0.11. CONCLUSIONS: No posterior capsule rupture was reported. Complete lens removal was achieved in 25 trials without significant surgical complications. Refinements to the procedures are required before fully automated lens extraction can be realized.
PURPOSE: To evaluate semiautomated surgical lens extraction procedures using the optical coherence tomography (OCT)-integrated Intraocular Robotic Interventional Surgical System. SETTING: Stein Eye Institute and Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, USA. DESIGN: Experimental study. METHODS: Semiautomated lens extraction was performed on postmortem pig eyes using a robotic platform integrated with an OCT imaging system. Lens extraction was performed using a series of automated steps including robot-to-eye alignment, irrigation/aspiration (I/A) handpiece insertion, anatomic modeling, surgical path planning, and I/A handpiece navigation. Intraoperative surgical supervision and human intervention were enabled by real-time OCT image feedback to the surgeon via a graphical user interface. Manual preparation of the pig-eye models, including the corneal incision and capsulorhexis, was performed by a trained cataract surgeon before the semiautomated lens extraction procedures. A scoring system was used to assess surgical complications in a postoperative evaluation. RESULTS: Complete lens extraction was achieved in 25 of 30 eyes. In the remaining 5 eyes, small lens pieces (≤1.0 mm3) were detected near the lens equator, where transpupillary OCT could not image. No posterior capsule rupture or corneal leakage occurred. The mean surgical duration was 277 seconds ± 42 (SD). Based on a 3-point scale (0 = no damage), damage to the iris was 0.33 ± 0.20, damage to the cornea was 1.47 ± 0.20 (due to tissue dehydration), and stress at the incision was 0.97 ± 0.11. CONCLUSIONS: No posterior capsule rupture was reported. Complete lens removal was achieved in 25 trials without significant surgical complications. Refinements to the procedures are required before fully automated lens extraction can be realized.
Authors: Kendall E Donaldson; Rosa Braga-Mele; Florence Cabot; Richard Davidson; Deepinder K Dhaliwal; Rex Hamilton; Mitchell Jackson; Larry Patterson; Karl Stonecipher; Sonia H Yoo Journal: J Cataract Refract Surg Date: 2013-11 Impact factor: 3.351
Authors: Gyeong Woo Cheon; Berk Gonenc; Russell H Taylor; Peter L Gehlbach; Jin U Kang Journal: IEEE ASME Trans Mechatron Date: 2017-09-05 Impact factor: 5.303
Authors: Carl Fisher; James Harty; Albert Yee; Celina L Li; Katarzyna Komolibus; Konstantin Grygoryev; Huihui Lu; Ray Burke; Brian C Wilson; Stefan Andersson-Engels Journal: J Biomed Opt Date: 2022-01 Impact factor: 3.758