Literature DB >> 28389702

Cooperative robot assistant for vitreoretinal microsurgery: development of the RVRMS and feasibility studies in an animal model.

Yi-Qi Chen1,2, Ji-Wei Tao1, Ling-Ya Su2, Liang Li2, Shi-Xin Zhao1, Yang Yang3, Li-Jun Shen4,5.   

Abstract

PURPOSE: The purpose of the study was to describe the development of a robotic aided surgical system named RVRMS (robotic vitreous retinal microsurgery system) and to evaluate the capability for using it to perform vitreoretinal surgery.
METHODS: The RVRMS was designed and built to include the key components of two independent arms. End-effectors of each arm fix various surgical instruments and perform intraocular manipulation. To evaluate properly the RVRMS, robot-assisted 23-gauge surgical tasks including endolaser for retinal photocoagulation, pars plana vitrectomy (PPV), retinal foreign body removal and retinal vascular cannulation were performed in two different sizes of an animal model. Endolaser was performed in the eye of a living Irish rabbit and the other tasks were done in a harvested porcine eye. For each evaluation, the duration and the successful completion of the task was assessed.
RESULTS: Robot-assisted vitreoretinal operations were successfully performed in nine rabbit eyes and 25 porcine eyes without any iatrogenic complication such as retinal tear or retinal detachment. In the task of using an endolaser, three rows of burns around the induced retinal hole were performed in nine rabbit eyes with half size intervals of laser spots. Nine procine eyes underwent PPV followed by successful posterior vitreous detachment (PVD) induction assisted with triamcinolone acetonide (TA). Nine porcine eyes completed removal of a fine stainless steel wire, which was inserted into prepared retinal tissue. Finally, retinal vascular cannulation with a piece of stainless steel wire (6mm length, 45 μm pipe diameter and one end cut to ∼30° slope) was successfully achieved in seven porcine eyes. The average duration of each procedure was 10.91±1.22 min, 11.68±2.11min, 5.90±0.46 min and 13.5±6.2 min, respectively.
CONCLUSIONS: Maneuverability, accuracy and stability of robot-assisted vitreoretinal microsurgery using the RVRMS were demonstrated in this study. Wider application research of robotic surgery and improvement of a robotic system should be continued.

Entities:  

Keywords:  Pars plana vitrectomy; Retinal vascular cannulation; Robot-assisted surgery; Robotic aided surgical system; Vitreoretinal microsurgery

Mesh:

Year:  2017        PMID: 28389702     DOI: 10.1007/s00417-017-3656-3

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  25 in total

1.  Transatlantic robot-assisted telesurgery.

Authors:  J Marescaux; J Leroy; M Gagner; F Rubino; D Mutter; M Vix; S E Butner; M K Smith
Journal:  Nature       Date:  2001-09-27       Impact factor: 49.962

2.  Evaluation of a stereoscopic camera-based three-dimensional viewing workstation for ophthalmic surgery.

Authors:  Prashant R Bhadri; Adrian P Rowley; Rahul N Khurana; Charles M Deboer; Ralph M Kerns; Lawrence P Chong; Mark S Humayun
Journal:  Am J Ophthalmol       Date:  2007-05       Impact factor: 5.258

3.  Robotic radical hysterectomy.

Authors:  James Fanning; Bradford Fenton; Manisha Purohit
Journal:  Am J Obstet Gynecol       Date:  2008-06       Impact factor: 8.661

4.  Cooperative robot assistant for retinal microsurgery.

Authors:  Ioana Fleming; Marcin Balicki; John Koo; Iulian Iordachita; Ben Mitchell; James Handa; Gregory Hager; Russell Taylor
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

5.  Robot-assisted vitreoretinal surgery: development of a prototype and feasibility studies in an animal model.

Authors:  Takashi Ueta; Yoshiharu Yamaguchi; Yoshihiro Shirakawa; Taiga Nakano; Ryuichi Ideta; Yasuo Noda; Akio Morita; Ryo Mochizuki; Naohiko Sugita; Mamoru Mitsuishi; Yasuhiro Tamaki
Journal:  Ophthalmology       Date:  2009-07-09       Impact factor: 12.079

6.  Three-dimensional video presentation of microsurgery by the cross-eyed viewing method using a high-definition video system.

Authors:  Yuzo Terakawa; Kenichi Ishibashi; Takeo Goto; Kenji Ohata
Journal:  Neurol Med Chir (Tokyo)       Date:  2011       Impact factor: 1.742

7.  Microsurgical robotic system for the deep surgical field: development of a prototype and feasibility studies in animal and cadaveric models.

Authors:  Akio Morita; Shigeo Sora; Mamoru Mitsuishi; Shinichi Warisawa; Katopo Suruman; Daisuke Asai; Junpei Arata; Shoichi Baba; Hidechika Takahashi; Ryo Mochizuki; Takaaki Kirino
Journal:  J Neurosurg       Date:  2005-08       Impact factor: 5.115

8.  Feasibility study on retinal vascular bypass surgery in isolated arterially perfused caprine eye model.

Authors:  Y Chen; W Wu; X Zhang; W Fan; L Shen
Journal:  Eye (Lond)       Date:  2011-09-16       Impact factor: 3.775

9.  Transcontinental robot-assisted remote telesurgery: feasibility and potential applications.

Authors:  Jacques Marescaux; Joel Leroy; Francesco Rubino; Michelle Smith; Michel Vix; Michele Simone; Didier Mutter
Journal:  Ann Surg       Date:  2002-04       Impact factor: 12.969

10.  Application of a three-dimensional microsurgical video system for a rat femoral vessel anastomosis.

Authors:  Jianfeng Liu; Bin Chen; Yong Ni; Yongqiang Zhan; Haibin Gao
Journal:  Chin Med J (Engl)       Date:  2014       Impact factor: 2.628

View more
  2 in total

1.  Combining robot-assisted surgical system and 3D visualization system for teaching minimally invasive vitreoretinal surgery.

Authors:  Yi-Qi Chen; Dan Cheng; Lin Zhu; Wei-Qian Gao; Jia-Feng Yu; Jun Wang; Xin-Yi Deng; Ji-Wei Tao; Jia Qu; Li-Jun Shen
Journal:  Int J Ophthalmol       Date:  2022-02-18       Impact factor: 1.779

2.  Porcine training models for endoscopic and robotic reconstructive breast surgery: a preliminary study.

Authors:  Joon Seok Lee; Jeeyeon Lee; Yun Hyun Kim; Ho Yong Park; Jung Dug Yang
Journal:  Gland Surg       Date:  2021-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.