Literature DB >> 23719095

Loosening after acetabular revision: comparison of trabecular metal and reinforcement rings. A systematic review.

Nicholas A Beckmann1, Stefan Weiss, Matthias C M Klotz, Matthias Gondan, Sebastian Jaeger, Rudi G Bitsch.   

Abstract

The best method of revision acetabular arthroplasty remains unclear. Consequently, we reviewed the literature on the treatment of revision acetabular arthroplasty using revision rings (1541 cases; mean follow-up (FU) 5.7 years) and Trabecular Metal, or TM, implants (1959 cases; mean FU 3.7 years) to determine if a difference with regard to revision failure could be determined. Failure rates of the respective implants were compared statistically using a logistic regression model with adjustment for discrepancies in FU time. In our study, TM shows statistically significant decreased loosening rates relative to revision rings for all grades including severe acetabular defects and pelvic discontinuity. The severe defects appear to benefit the most from TM.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  acetabular revision; revision hip arthroplasty; revision rings; trabecular metal

Mesh:

Year:  2013        PMID: 23719095     DOI: 10.1016/j.arth.2013.04.035

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  25 in total

1.  [Modular reconstruction in acetabular revision with antiprotrusio cages and metal augments : the cage-and-augment system].

Authors:  K-P Günther; T Wegner; S Kirschner; A Hartmann
Journal:  Oper Orthop Traumatol       Date:  2014-04-02       Impact factor: 1.154

2.  [Treatment of acetabular defects with the trabecular metal revision system].

Authors:  G I Wassilew; V Janz; C Perka; M Müller
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

3.  Outcome of cages in revision arthroplasty of the acetabulum: a systematic review.

Authors:  Alessandro Aprato; Matteo Olivero; Luigi Branca Vergano; Alessandro Massè
Journal:  Acta Biomed       Date:  2019-01-10

4.  Acetabular revision arthroplasty using trabecular titanium implants.

Authors:  Boris Steno; Milan Kokavec; Libor Necas
Journal:  Int Orthop       Date:  2014-09-06       Impact factor: 3.075

5.  Management of severe periacetabular bone loss combined with pelvic discontinuity in revision hip arthroplasty.

Authors:  Max J Friedrich; Jan Schmolders; Robert D Michel; Thomas M Randau; Matthias D Wimmer; Hendrik Kohlhof; Dieter C Wirtz; Sascha Gravius
Journal:  Int Orthop       Date:  2014-07-16       Impact factor: 3.075

6.  Acetabular defect reconstruction in revision hip arthroplasty with a modular revision system and biological defect augmentation.

Authors:  Jan Schmolders; Max J Friedrich; Robert D Michel; Thomas M Randau; Matthias D Wimmer; Andreas C Strauss; Hendrik Kohlhof; Dieter C Wirtz; Sascha Gravius
Journal:  Int Orthop       Date:  2014-10-04       Impact factor: 3.075

Review 7.  [Periprosthetic acetabular fractures in geriatric patients].

Authors:  S C Herath; M F R Rollmann; T Histing; J H Holstein; T Pohlemann
Journal:  Chirurg       Date:  2017-02       Impact factor: 0.955

8.  Management of periprosthetic acetabular fractures in elderly patients--a minimally invasive approach.

Authors:  Ralph Zettl; Daphne Eschbach; Steffen Ruchholtz
Journal:  Int Orthop       Date:  2015-07-28       Impact factor: 3.075

9.  Acetabular reconstruction using a free fibular autograft in total hip arthroplasty revisions.

Authors:  Thibaut Noailles; Chiaki Tanaka; Francois Lintz; Sylvie Collon; Kevin Bargoin; Francois Gouin
Journal:  Int Orthop       Date:  2014-07-20       Impact factor: 3.075

10.  [Traumatic periprosthetic fractures in patients with total hip replacement].

Authors:  Philipp Lichte; Philipp Kobbe; Miguel Pishnamaz; Frank Hildebrand
Journal:  Unfallchirurg       Date:  2019-11       Impact factor: 1.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.