Literature DB >> 23680761

Scheimpflug imaging for laser refractive surgery.

Renato Ambrósio1, Bruno F Valbon, Fernando Faria-Correia, Isaac Ramos, Allan Luz.   

Abstract

PURPOSE OF REVIEW: To review the principles and clinical applications of Scheimpflug corneal and anterior segment imaging with special relevance for laser refractive surgery. RECENT
FINDINGS: Computerized Scheimpflug imaging has been used for corneal and anterior segment tomography (CASTm) in different commercially available instruments. Such approach computes the three-dimensional image of the cornea and anterior segment, enabling the characterization of elevation and curvature of the front and back surfaces of the cornea, pachymetric mapping, calculation of the total corneal refractive power and anterior segment biometry. CASTm represents a major evolution for corneal and anterior segment analysis, beyond front surface corneal topography and single point central corneal thickness measurements. This approach enhances the diagnostic abilities for screening ectasia risk as well as for planning, evaluating the results, managing complications of refractive procedures, and selecting intraocular lens power, type, and design. In addition, dynamic Scheimpflug imaging has been recently introduced for in-vivo corneal biomechanical measurements and has also been used for anterior segment imaging of femtocataract surgery.
SUMMARY: Scheimpflug imaging has an important role for laser refractive surgery with different applications, which continuously improve due to advances in technology.

Entities:  

Mesh:

Year:  2013        PMID: 23680761     DOI: 10.1097/ICU.0b013e3283622a94

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  25 in total

1.  A novel zernike application to differentiate between three-dimensional corneal thickness of normal corneas and corneas with keratoconus.

Authors:  Rohit Shetty; Himanshu Matalia; Purnima Srivatsa; Arkasubhra Ghosh; William J Dupps; Abhijit Sinha Roy
Journal:  Am J Ophthalmol       Date:  2015-06-09       Impact factor: 5.258

2.  Screening Candidates for Refractive Surgery With Corneal Tomographic-Based Deep Learning.

Authors:  Yi Xie; Lanqin Zhao; Xiaonan Yang; Xiaohang Wu; Yahan Yang; Xiaoman Huang; Fang Liu; Jiping Xu; Limian Lin; Haiqin Lin; Qiting Feng; Haotian Lin; Quan Liu
Journal:  JAMA Ophthalmol       Date:  2020-05-01       Impact factor: 7.389

3.  Automatic method of analysis and measurement of additional parameters of corneal deformation in the Corvis tonometer.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2014-11-19       Impact factor: 2.819

4.  Open source software for the analysis of corneal deformation parameters on the images from the Corvis tonometer.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2015-04-11       Impact factor: 2.819

Review 5.  Corneal topography in keratoconus: state of the art.

Authors:  F Cavas-Martínez; E De la Cruz Sánchez; J Nieto Martínez; F J Fernández Cañavate; D G Fernández-Pacheco
Journal:  Eye Vis (Lond)       Date:  2016-02-22

Review 6.  Applications of Scheimpflug Imaging in Glaucoma Management: Current and Potential Applications.

Authors:  Alexander T Nguyen; Tiffany Liu; Ji Liu
Journal:  J Ophthalmol       Date:  2016-12-04       Impact factor: 1.909

7.  Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications.

Authors:  Renato Ambrósio; Fernando Faria Correia; Bernardo Lopes; Marcella Q Salomão; Allan Luz; Daniel G Dawson; Ahmed Elsheikh; Riccardo Vinciguerra; Paolo Vinciguerra; Cynthia J Roberts
Journal:  Open Ophthalmol J       Date:  2017-07-31

8.  Changes of corneal tomography in patients with congenital blepharoptosis.

Authors:  Tiepei Zhu; Xin Ye; Peifang Xu; Jingyi Wang; Huina Zhang; Hailong Ni; Zhaoan Su; Juan Ye
Journal:  Sci Rep       Date:  2017-07-26       Impact factor: 4.379

9.  Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug+Placido device.

Authors:  Gaurav Prakash; Dhruv Srivastava
Journal:  J Optom       Date:  2015-09-01

Review 10.  Dynamic corneal deformation response and integrated corneal tomography.

Authors:  Marcella Q Salomão; Ana Luisa Hofling-Lima; Fernando Faria-Correia; Bernardo Teixeira Lopes; Sandra Rodrigues-Barros; Cynthia J Roberts; Renato Ambrósio
Journal:  Indian J Ophthalmol       Date:  2018-03       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.