Literature DB >> 23657861

Fibrin sealant for mesh fixation in laparoscopic umbilical hernia repair: 1-year results of a randomized controlled double-blinded study.

J R Eriksen1, T Bisgaard, S Assaadzadeh, L N Jorgensen, J Rosenberg.   

Abstract

PURPOSE: Fibrin sealant for mesh fixation has significant positive effects on early outcome after laparoscopic ventral hernia repair (LVHR) compared with titanium tacks. Whether fibrin sealant fixation also results in better long-term outcome is unknown.
METHODS: We performed a randomized controlled trial including patients with umbilical hernia defects from 1.5 to 5 cm at three Danish hernia centres. We used a 12 cm circular mesh. Participants were randomized to fibrin sealant or titanium tack fixation. Patients were seen in the outpatient clinic at 1 and 12 months follow-up.
RESULTS: Forty patients were included of whom 34 were available for intention to treat analysis after 1 year. There were no significant differences in pain, discomfort, fatigue, satisfaction or quality of life between the two groups at the 1-year follow-up. Five patients (26 %) in the fibrin sealant group and one (6 %) in the tack group were diagnosed with a recurrence at the 1-year follow-up (p = 0.182) (overall recurrence rate 17 %). Hernia defects in patients with recurrence were significantly larger than in those without recurrence (median 4.0 vs. 2.8 cm, p = 0.009).
CONCLUSION: Patients with larger hernia defects and fibrin sealant mesh fixation had higher recurrence rates than expected, although the study was not powered for assessment of recurrence. There was no significant difference between groups in any parameters after the 1-year follow-up. The beneficial effects of mesh fixation with fibrin sealant on early outcome warrant further studies on optimization of the surgical technique to prevent recurrence.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23657861     DOI: 10.1007/s10029-013-1101-z

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  11 in total

1.  Evaluation of acute fixation strength of absorbable and nonabsorbable barrier coated mesh secured with fibrin sealant.

Authors:  E D Jenkins; L Melman; M M Frisella; C R Deeken; B D Matthews
Journal:  Hernia       Date:  2010-05-09       Impact factor: 4.739

2.  The suturing concept for laparoscopic mesh fixation in ventral and incisional hernia repair: Mid-term analysis of 400 cases.

Authors:  E Chelala; M Thoma; B Tatete; A C Lemye; M Dessily; J L Alle
Journal:  Surg Endosc       Date:  2006-12-06       Impact factor: 4.584

3.  Histologic evaluation of absorbable and non-absorbable barrier coated mesh secured to the peritoneum with fibrin sealant in a New Zealand white rabbit model.

Authors:  E D Jenkins; L Melman; S Desai; C R Deeken; S C Greco; M M Frisella; B D Matthews
Journal:  Hernia       Date:  2011-05-24       Impact factor: 4.739

4.  Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical hernia repair.

Authors:  J R Eriksen; T Bisgaard; S Assaadzadeh; L Nannestad Jorgensen; J Rosenberg
Journal:  Br J Surg       Date:  2011-08-24       Impact factor: 6.939

5.  Impact of the number of tacks on postoperative pain in laparoscopic repair of ventral hernias: do more tacks cause more pain?

Authors:  Ernst J P Schoenmaeckers; Robert J de Haas; Vincent Stirler; Johan T F J Raymakers; Srdjan Rakic
Journal:  Surg Endosc       Date:  2011-09-05       Impact factor: 4.584

6.  Pain, quality of life and recovery after laparoscopic ventral hernia repair.

Authors:  J R Eriksen; P Poornoroozy; L N Jørgensen; B Jacobsen; H U Friis-Andersen; J Rosenberg
Journal:  Hernia       Date:  2008-08-01       Impact factor: 4.739

Review 7.  [The problem of mesh shrinkage in laparoscopic incisional hernia repair].

Authors:  J Jonas
Journal:  Zentralbl Chir       Date:  2009-06-17       Impact factor: 0.942

8.  Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel) vs. titanium tacks: a randomised controlled experimental study in pigs.

Authors:  J R Eriksen; J I Bech; D Linnemann; J Rosenberg
Journal:  Hernia       Date:  2008-05-16       Impact factor: 4.739

Review 9.  Choice of mesh for laparoscopic ventral hernia repair.

Authors:  J R Eriksen; I Gögenur; J Rosenberg
Journal:  Hernia       Date:  2007-09-11       Impact factor: 4.739

10.  Use of fibrin glue (Tissucol) in laparoscopic repair of abdominal wall defects: preliminary experience.

Authors:  S Olmi; A Scaini; L Erba; E Croce
Journal:  Surg Endosc       Date:  2006-12-20       Impact factor: 3.453

View more
  11 in total

1.  Prospective randomized trial of mesh fixation with absorbable versus nonabsorbable tacker in laparoscopic ventral incisional hernia repair.

Authors:  Elif Colak; Nuraydin Ozlem; Gultekin Ozan Kucuk; Recep Aktimur; Sadik Kesmer; Kadir Yildirim
Journal:  Int J Clin Exp Med       Date:  2015-11-15

2.  The use of cyanoacrylate sealant as simple mesh fixation in laparoscopic ventral hernia repair: a large animal evaluation.

Authors:  E Reynvoet; S Van Cleven; I Van Overbeke; K Chiers; P De Baets; R Troisi; F Berrevoet
Journal:  Hernia       Date:  2015-02-03       Impact factor: 4.739

3.  Atraumatic laparoscopic intraperitoneal mesh fixation using a new laparoscopic device: an animal experimental study.

Authors:  R N Villalobos; M C Mias; C Gas; Y Maestre; M Nogués; F Vilardell; J J Olsina
Journal:  Hernia       Date:  2019-07-19       Impact factor: 4.739

4.  Mesh fixation using novel bio-adhesive coating compared to tack fixation for IPOM hernia repair: in vivo evaluation in a porcine model.

Authors:  Amir Ben Yehuda; Abraham Nyska; Amir Szold
Journal:  Surg Endosc       Date:  2019-05-08       Impact factor: 4.584

5.  Mesh shrinkage depends on mesh properties and anchoring device: an experimental long-term study in sheep.

Authors:  S Harsløf; N Zinther; T Harsløf; C Danielsen; P Wara; H Friis-Andersen
Journal:  Hernia       Date:  2016-08-11       Impact factor: 4.739

6.  Substantial variation among hernia experts in the decision for treatment of patients with incisional hernia: a descriptive study on agreement.

Authors:  D Kokotovic; I Gögenur; F Helgstrand
Journal:  Hernia       Date:  2016-12-03       Impact factor: 4.739

Review 7.  Evolution and advances in laparoscopic ventral and incisional hernia repair.

Authors:  Alan L Vorst; Christodoulos Kaoutzanis; Alfredo M Carbonell; Michael G Franz
Journal:  World J Gastrointest Surg       Date:  2015-11-27

8.  Adhesions to sutures, tackers, and glue for intraperitoneal mesh fixation: an experimental study.

Authors:  M H F Schreinemacher; K W Y van Barneveld; E Peeters; M Miserez; M J J Gijbels; J-W M Greve; N D Bouvy
Journal:  Hernia       Date:  2013-11-24       Impact factor: 4.739

9.  Long-term follow-up results of umbilical hernia repair.

Authors:  Linas Venclauskas; Mantas Jokubauskas; Justas Zilinskas; Kristina Zviniene; Mindaugas Kiudelis
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2017-09-26       Impact factor: 1.195

10.  Mesh fixation techniques in primary ventral or incisional hernia repair.

Authors:  Tim Mathes; Barbara Prediger; Maren Walgenbach; Robert Siegel
Journal:  Cochrane Database Syst Rev       Date:  2021-05-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.