Literature DB >> 21964681

Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical hernia repair.

J R Eriksen1, T Bisgaard, S Assaadzadeh, L Nannestad Jorgensen, J Rosenberg.   

Abstract

BACKGROUND: The use of tacks for mesh fixation may induce pain after surgery for ventral hernia. The aim of this study was to compare postoperative pain after laparoscopic ventral hernia repair (LVHR) with conventional mesh fixation using titanium tacks versus fibrin sealant (FS).
METHODS: This randomized clinical trial included patients with an umbilical hernia defect ranging from 1·5 to 5 cm at three Danish hernia centres. Participants were assigned randomly to FS or titanium tack fixation. The primary outcome was acute pain, defined as the mean pain score on days 0-2 after surgery, measured on a 0-100-mm visual analogue scale (VAS).
RESULTS: Forty patients were included, of whom 38 were available for intention-to-treat analysis after 1 month. Patients in the FS group reported less pain than those in the tack group on days 0-2, both at rest (median 19 versus 47 mm; P = 0·025) and during activity (38 versus 60 mm; P = 0·014). The absolute difference in pain score between groups was 19 (95 per cent confidence interval 3 to 34) and 20 (4 to 35) mm at rest and during activity respectively. Patients in the FS group resumed normal daily activity earlier (after median 7 versus 18 days; P = 0·027) and reported significantly less discomfort. No recurrences were observed.
CONCLUSION: Mesh fixation with FS in LVHR was associated with less acute postoperative pain, discomfort and a shorter convalescence than tack fixation. Long-term follow-up is needed to show whether the effect of FS fixation persists in terms of chronic pain and recurrence. REGISTRATION NUMBER: NCT00842842 (http://www.clinicaltrials.gov).
Copyright © 2011 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21964681     DOI: 10.1002/bjs.7646

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  26 in total

1.  Evaluation of fibrin sealant for biologic mesh fixation at the hiatus in a porcine model.

Authors:  David M Krpata; Jeffrey A Blatnik; Karem C Harth; Melissa S Phillips; Yuri W Novitsky; Michael J Rosen
Journal:  Surg Endosc       Date:  2012-04-27       Impact factor: 4.584

Review 2.  Use of fibrin sealant (Tisseel/Tissucol) in hernia repair: a systematic review.

Authors:  René H Fortelny; Alexander H Petter-Puchner; Karl S Glaser; Heinz Redl
Journal:  Surg Endosc       Date:  2012-01-26       Impact factor: 4.584

3.  Ultrasound biomicroscopy (UBM) and scanning acoustic microscopy (SAM) for the assessment of hernia mesh integration: a comparison to standard histology in an experimental model.

Authors:  A Petter-Puchner; S Gruber-Blum; N Walder; R H Fortelny; H Redl; K Raum
Journal:  Hernia       Date:  2013-12-18       Impact factor: 4.739

Review 4.  Laparoscopic ventral hernia repair: is there an optimal mesh fixation technique? A systematic review.

Authors:  Emmelie Reynvoet; Ellen Deschepper; Xavier Rogiers; Roberto Troisi; Frederik Berrevoet
Journal:  Langenbecks Arch Surg       Date:  2014-01       Impact factor: 3.445

5.  The use of cyanoacrylate sealant as simple mesh fixation in laparoscopic ventral hernia repair: a large animal evaluation.

Authors:  E Reynvoet; S Van Cleven; I Van Overbeke; K Chiers; P De Baets; R Troisi; F Berrevoet
Journal:  Hernia       Date:  2015-02-03       Impact factor: 4.739

6.  Effect of fixation devices on postoperative pain after laparoscopic ventral hernia repair: a randomized clinical trial of permanent tacks, absorbable tacks, and synthetic glue.

Authors:  Sanne Harsløf; Pia Krum-Møller; Thorbjørn Sommer; Nellie Zinther; Pål Wara; Hans Friis-Andersen
Journal:  Langenbecks Arch Surg       Date:  2018-05-25       Impact factor: 3.445

7.  A systematic methodological review of reported perioperative variables, postoperative outcomes and hernia recurrence from randomised controlled trials of elective ventral hernia repair: clear definitions and standardised datasets are needed.

Authors:  Samuel G Parker; C P J Wood; J W Butterworth; R W Boulton; A A O Plumb; S Mallett; S Halligan; A C J Windsor
Journal:  Hernia       Date:  2018-01-05       Impact factor: 4.739

8.  Fibrin sealant for mesh fixation in laparoscopic umbilical hernia repair: 1-year results of a randomized controlled double-blinded study.

Authors:  J R Eriksen; T Bisgaard; S Assaadzadeh; L N Jorgensen; J Rosenberg
Journal:  Hernia       Date:  2013-05-09       Impact factor: 4.739

9.  Atraumatic laparoscopic intraperitoneal mesh fixation using a new laparoscopic device: an animal experimental study.

Authors:  R N Villalobos; M C Mias; C Gas; Y Maestre; M Nogués; F Vilardell; J J Olsina
Journal:  Hernia       Date:  2019-07-19       Impact factor: 4.739

10.  Ventral hernia mesh tack causes liver hemorrhage.

Authors:  G Baltazar; K Coakley; A Badiwala; A Chendrasekhar
Journal:  Hernia       Date:  2012-10-18       Impact factor: 4.739

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.