A novel CT acquisition and analysis technique for breathing motion modeling.

Daniel A Low1, Benjamin M White, Percy P Lee, David H Thomas, Sergio Gaudio, Shyam S Jani, Xiao Wu, James M Lamb.   

Abstract

To report on a novel technique for providing artifact-free quantitative four-dimensional computed tomography (4DCT) image datasets for breathing motion modeling. Commercial clinical 4DCT methods have difficulty managing irregular breathing. The resulting images contain motion-induced artifacts that can distort structures and inaccurately characterize breathing motion. We have developed a novel scanning and analysis method for motion-correlated CT that utilizes standard repeated fast helical acquisitions, a simultaneous breathing surrogate measurement, deformable image registration, and a published breathing motion model. The motion model differs from the CT-measured motion by an average of 0.65 mm, indicating the precision of the motion model. The integral of the divergence of one of the motion model parameters is predicted to be a constant 1.11 and is found in this case to be 1.09, indicating the accuracy of the motion model. The proposed technique shows promise for providing motion-artifact free images at user-selected breathing phases, accurate Hounsfield units, and noise characteristics similar to non-4D CT techniques, at a patient dose similar to or less than current 4DCT techniques.

Entities:  

Mesh:

Year:  2013        PMID: 23640212      PMCID: PMC3685480          DOI: 10.1088/0031-9155/58/11/L31

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Artifacts in computed tomography scanning of moving objects.

Authors:  George T Y Chen; Jong H Kung; Kevin P Beaudette
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

2.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning.

Authors:  E C Ford; G S Mageras; E Yorke; C C Ling
Journal:  Med Phys       Date:  2003-01       Impact factor: 4.071

3.  Application of the continuity equation to a breathing motion model.

Authors:  Daniel A Low; Tianyu Zhao; Benjamin White; Deshan Yang; Sasa Mutic; Camille E Noel; Jeffrey D Bradley; Parag J Parikh; Wei Lu
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

4.  A rigidity penalty term for nonrigid registration.

Authors:  Marius Staring; Stefan Klein; Josien P W Pluim
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

5.  elastix: a toolbox for intensity-based medical image registration.

Authors:  Stefan Klein; Marius Staring; Keelin Murphy; Max A Viergever; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

6.  Novel breathing motion model for radiotherapy.

Authors:  Daniel A Low; Parag J Parikh; Wei Lu; James F Dempsey; Sasha H Wahab; James P Hubenschmidt; Michelle M Nystrom; Maureen Handoko; Jeffrey D Bradley
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-11-01       Impact factor: 7.038

7.  A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT.

Authors:  Wei Lu; Parag J Parikh; James P Hubenschmidt; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

8.  Phase and amplitude binning for 4D-CT imaging.

Authors:  A F Abdelnour; S A Nehmeh; T Pan; J L Humm; P Vernon; H Schöder; K E Rosenzweig; G S Mageras; E Yorke; S M Larson; Y E Erdi
Journal:  Phys Med Biol       Date:  2007-05-18       Impact factor: 3.609

9.  From phase-based to displacement-based gating: a software tool to facilitate respiration-gated radiation treatment.

Authors:  Joseph P Santoro; Ellen Yorke; Karyn A Goodman; Gig S Mageras
Journal:  J Appl Clin Med Phys       Date:  2009-10-07       Impact factor: 2.102

10.  Phase versus amplitude sorting of 4D-CT data.

Authors:  Nicole Wink; Christoph Panknin; Timothy D Solberg
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

View more
  11 in total

1.  Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

Authors:  Min Li; Sarah Joy Castillo; Richard Castillo; Edward Castillo; Thomas Guerrero; Liang Xiao; Xiaolin Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-14       Impact factor: 2.924

2.  Comparison of breathing gated CT images generated using a 5DCT technique and a commercial clinical protocol in a porcine model.

Authors:  Dylan P O'Connell; David H Thomas; Tai H Dou; James M Lamb; Franklin Feingold; Daniel A Low; Matthew K Fuld; Jered P Sieren; Chelsea M Sloan; Melissa A Shirk; Eric A Hoffman; Christian Hofmann
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

3.  Objective function to obtain multiple representative waveforms for a novel helical CT scan protocol.

Authors:  Dan Ruan; David Thomas; Daniel A Low
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

4.  Modeling and incorporating cardiac-induced lung tissue motion in a breathing motion model.

Authors:  Benjamin M White; Anand Santhanam; David Thomas; Yugang Min; James M Lamb; Jack Neylon; Shyam Jani; Sergio Gaudio; Subashini Srinivasan; Daniel Ennis; Daniel A Low
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

5.  A novel fast helical 4D-CT acquisition technique to generate low-noise sorting artifact-free images at user-selected breathing phases.

Authors:  David Thomas; James Lamb; Benjamin White; Shyam Jani; Sergio Gaudio; Percy Lee; Dan Ruan; Michael McNitt-Gray; Daniel Low
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-07       Impact factor: 7.038

6.  Investigating the minimum scan parameters required to generate free-breathing motion artefact-free fast-helical CT.

Authors:  David H Thomas; Jun Tan; Jack Neylon; Tai Dou; Dylan O'Connell; Michael McNitt-Gray; Percy Lee; James Lamb; Daniel A Low
Journal:  Br J Radiol       Date:  2017-11-21       Impact factor: 3.039

7.  Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity.

Authors:  Guang Li; Marshall Caraveo; Jie Wei; Andreas Rimner; Abraham J Wu; Karyn A Goodman; Ellen Yorke
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

8.  Ventilation measurements using fast-helical free-breathing computed tomography.

Authors:  Daniel A Low; Dylan O'Connell; Michael Lauria; Bradley Stiehl; Louise Naumann; Percy Lee; John Hegde; Igor Barjaktarevic; Jonathan Goldin; Anand Santhanam
Journal:  Med Phys       Date:  2021-09-04       Impact factor: 4.506

9.  A Method for Assessing Ground-Truth Accuracy of the 5DCT Technique.

Authors:  Tai H Dou; David H Thomas; Dylan P O'Connell; James M Lamb; Percy Lee; Daniel A Low
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-08-07       Impact factor: 7.038

10.  Evaluation of 4D CT acquisition methods designed to reduce artifacts.

Authors:  Sarah J Castillo; Richard Castillo; Edward Castillo; Tinsu Pan; Geoffrey Ibbott; Peter Balter; Brian Hobbs; Thomas Guerrero
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.