Literature DB >> 23620367

Combination of one-view digital breast tomosynthesis with one-view digital mammography versus standard two-view digital mammography: per lesion analysis.

Gisella Gennaro1, R Edward Hendrick, Alicia Toledano, Jean R Paquelet, Elisabetta Bezzon, Roberta Chersevani, Cosimo di Maggio, Manuela La Grassa, Luigi Pescarini, Ilaria Polico, Alessandro Proietti, Enrica Baldan, Fabio Pomerri, Pier Carlo Muzzio.   

Abstract

OBJECTIVE: To evaluate the clinical value of combining one-view mammography (cranio-caudal, CC) with the complementary view tomosynthesis (mediolateral-oblique, MLO) in comparison to standard two-view mammography (MX) in terms of both lesion detection and characterization.
METHODS: A free-response receiver operating characteristic (FROC) experiment was conducted independently by six breast radiologists, obtaining data from 463 breasts of 250 patients. Differences in mean lesion detection fraction (LDF) and mean lesion characterization fraction (LCF) were analysed by analysis of variance (ANOVA) to compare clinical performance of the combination of techniques to standard two-view digital mammography.
RESULTS: The 463 cases (breasts) reviewed included 258 with one to three lesions each, and 205 with no lesions. The 258 cases with lesions included 77 cancers in 68 breasts and 271 benign lesions to give a total of 348 proven lesions. The combination, DBT(MLO)+MX(CC), was superior to MX (CC+MLO) in both lesion detection (LDF) and lesion characterization (LCF) overall and for benign lesions. DBT(MLO)+MX(CC) was non-inferior to two-view MX for malignant lesions.
CONCLUSIONS: This study shows that readers' capabilities in detecting and characterizing breast lesions are improved by combining single-view digital breast tomosynthesis and single-view mammography compared to two-view digital mammography. KEY POINTS: • Digital breast tomosynthesis is becoming adopted as an adjunct to mammography (MX) • DBT (MLO) +MX (CC) is superior to MX (CC+MLO) in lesion detection (overall and benign lesions) • DBT (MLO) +MX (CC) is non-inferior to MX (CC+MLO) in cancer detection • DBT (MLO) +MX (CC) is superior to MX (CC+MLO) in lesion characterization (overall and benign lesions) • DBT (MLO) +MX (CC) is non-inferior to MX (CC+MLO) in characterization of malignant lesions.

Entities:  

Mesh:

Year:  2013        PMID: 23620367     DOI: 10.1007/s00330-013-2831-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  Observer studies involving detection and localization: modeling, analysis, and validation.

Authors:  Dev P Chakraborty; Kevin S Berbaum
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

2.  Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-ray imaging observer study.

Authors:  Matthew G Wallis; Elin Moa; Federica Zanca; Karin Leifland; Mats Danielsson
Journal:  Radiology       Date:  2012-01-24       Impact factor: 11.105

3.  A comparison of reconstruction algorithms for breast tomosynthesis.

Authors:  Tao Wu; Richard H Moore; Elizabeth A Rafferty; Daniel B Kopans
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

4.  A comparison of denominator degrees of freedom methods for multiple observer ROC analysis.

Authors:  Stephen L Hillis
Journal:  Stat Med       Date:  2007-02-10       Impact factor: 2.373

5.  Digital breast tomosynthesis: observer performance study.

Authors:  David Gur; Gordon S Abrams; Denise M Chough; Marie A Ganott; Christiane M Hakim; Ronald L Perrin; Grace Y Rathfon; Jules H Sumkin; Margarita L Zuley; Andriy I Bandos
Journal:  AJR Am J Roentgenol       Date:  2009-08       Impact factor: 3.959

6.  Performance comparison of single-view digital breast tomosynthesis plus single-view digital mammography with two-view digital mammography.

Authors:  Gisella Gennaro; R Edward Hendrick; Patricia Ruppel; Roberta Chersevani; Cosimo di Maggio; Manuela La Grassa; Luigi Pescarini; Ilaria Polico; Alessandro Proietti; Enrica Baldan; Elisabetta Bezzon; Fabio Pomerri; Pier Carlo Muzzio
Journal:  Eur Radiol       Date:  2012-09-14       Impact factor: 5.315

7.  A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis.

Authors:  M J Michell; A Iqbal; R K Wasan; D R Evans; C Peacock; C P Lawinski; A Douiri; R Wilson; P Whelehan
Journal:  Clin Radiol       Date:  2012-05-23       Impact factor: 2.350

8.  Diagnostic performance of digital versus film mammography for breast-cancer screening.

Authors:  Etta D Pisano; Constantine Gatsonis; Edward Hendrick; Martin Yaffe; Janet K Baum; Suddhasatta Acharyya; Emily F Conant; Laurie L Fajardo; Lawrence Bassett; Carl D'Orsi; Roberta Jong; Murray Rebner
Journal:  N Engl J Med       Date:  2005-09-16       Impact factor: 91.245

Review 9.  Screening for breast cancer.

Authors:  Joann G Elmore; Katrina Armstrong; Constance D Lehman; Suzanne W Fletcher
Journal:  JAMA       Date:  2005-03-09       Impact factor: 56.272

10.  Analysis of cancers missed at screening mammography.

Authors:  R E Bird; T W Wallace; B C Yankaskas
Journal:  Radiology       Date:  1992-09       Impact factor: 11.105

View more
  15 in total

1.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

2.  Digital breast tomosynthesis: observer performance of clustered microcalcification detection on breast phantom images acquired with an experimental system using variable scan angles, angular increments, and number of projection views.

Authors:  Heang-Ping Chan; Mitchell M Goodsitt; Mark A Helvie; Scott Zelakiewicz; Andrea Schmitz; Mitra Noroozian; Chintana Paramagul; Marilyn A Roubidoux; Alexis V Nees; Colleen H Neal; Paul Carson; Yao Lu; Lubomir Hadjiiski; Jun Wei
Journal:  Radiology       Date:  2014-07-07       Impact factor: 11.105

3.  Comparative evaluation of average glandular dose and breast cancer detection between single-view digital breast tomosynthesis (DBT) plus single-view digital mammography (DM) and two-view DM: correlation with breast thickness and density.

Authors:  Sung Ui Shin; Jung Min Chang; Min Sun Bae; Su Hyun Lee; Nariya Cho; Mirinae Seo; Won Hwa Kim; Woo Kyung Moon
Journal:  Eur Radiol       Date:  2014-09-03       Impact factor: 5.315

4.  Diagnostic performance of dual-energy contrast-enhanced subtracted mammography in dense breasts compared to mammography alone: interobserver blind-reading analysis.

Authors:  Yun-Chung Cheung; Yu-Ching Lin; Yung-Liang Wan; Kee-Min Yeow; Pei-Chin Huang; Yung-Feng Lo; Hsiu-Pei Tsai; Shir-Hwa Ueng; Chee-Jen Chang
Journal:  Eur Radiol       Date:  2014-06-14       Impact factor: 5.315

5.  Imaging features and conspicuity of invasive lobular carcinomas on digital breast tomosynthesis.

Authors:  Foucauld Chamming's; Ellen Kao; Ann Aldis; Romuald Ferré; Atilla Omeroglu; Caroline Reinhold; Benoit Mesurolle
Journal:  Br J Radiol       Date:  2017-04-03       Impact factor: 3.039

6.  Digital breast tomosynthesis at screening assessment: are two views always necessary?

Authors:  Rabea Haq; Yit Y Lim; Anthony J Maxwell; Emma Hurley; Ursula Beetles; Sara Bundred; Mary Wilson; Susan Astley; Fiona J Gilbert
Journal:  Br J Radiol       Date:  2015-09-16       Impact factor: 3.039

7.  Characterization of Breast Masses in Digital Breast Tomosynthesis and Digital Mammograms: An Observer Performance Study.

Authors:  Heang-Ping Chan; Mark A Helvie; Lubomir Hadjiiski; Deborah O Jeffries; Katherine A Klein; Colleen H Neal; Mitra Noroozian; Chintana Paramagul; Marilyn A Roubidoux
Journal:  Acad Radiol       Date:  2017-06-21       Impact factor: 3.173

8.  Digital Breast Tomosynthesis guided Near Infrared Spectroscopy: Volumetric estimates of fibroglandular fraction and breast density from tomosynthesis reconstructions.

Authors:  Srinivasan Vedantham; Linxi Shi; Kelly E Michaelsen; Venkataramanan Krishnaswamy; Brian W Pogue; Steven P Poplack; Andrew Karellas; Keith D Paulsen
Journal:  Biomed Phys Eng Express       Date:  2015-10-27

9.  Detection and characterization of breast lesions in a selective diagnostic population: diagnostic accuracy study for comparison between one-view digital breast tomosynthesis and two-view full-field digital mammography.

Authors:  Eun Young Chae; Hak Hee Kim; Joo Hee Cha; Hee Jung Shin; Woo Jung Choi
Journal:  Br J Radiol       Date:  2016-04-13       Impact factor: 3.039

Review 10.  Strategies to Increase Cancer Detection: Review of True-Positive and False-Negative Results at Digital Breast Tomosynthesis Screening.

Authors:  Katrina E Korhonen; Susan P Weinstein; Elizabeth S McDonald; Emily F Conant
Journal:  Radiographics       Date:  2016-10-07       Impact factor: 5.333

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.