Literature DB >> 23609683

Averaging techniques for OCT imaging.

Maciej Szkulmowski1, Maciej Wojtkowski.   

Abstract

State-of-the-art Fourier-domain optical coherence tomography (OCT) allows for the acquisition of up to millions of spectral fringes per second. This large amount of data can be used to improve the quality of structural tomograms after effective averaging. Here, we compare three OCT image improvement techniques: magnitude averaging, complex averaging, and spectral and time domain OCT (STdOCT). We evaluate the performance for images on both linear and logarithmic intensity scales and discuss their advantages and disadvantages. We propose the use of the STdOCT approach as it offers the best advantages. Applications to in vivo imaging and speckle reduction are presented.

Mesh:

Year:  2013        PMID: 23609683     DOI: 10.1364/OE.21.009757

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  19 in total

1.  Processing-Aware Real-Time Rendering for Optimized Tissue Visualization in Intraoperative 4D OCT.

Authors:  Jakob Weiss; Michael Sommersperger; Ali Nasseri; Abouzar Eslami; Ulrich Eck; Nassir Navab
Journal:  Med Image Comput Comput Assist Interv       Date:  2020-09-29

2.  Multi-MHz retinal OCT.

Authors:  Thomas Klein; Wolfgang Wieser; Lukas Reznicek; Aljoscha Neubauer; Anselm Kampik; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

3.  Multi-penalty conditional random field approach to super-resolved reconstruction of optical coherence tomography images.

Authors:  Ameneh Boroomand; Alexander Wong; Edward Li; Daniel S Cho; Betty Ni; Kostandinka Bizheva
Journal:  Biomed Opt Express       Date:  2013-09-06       Impact factor: 3.732

4.  Spectrometer calibration for spectroscopic Fourier domain optical coherence tomography.

Authors:  Maciej Szkulmowski; Szymon Tamborski; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2016-11-09       Impact factor: 3.732

5.  Flexible A-scan rate MHz-OCT: efficient computational downscaling by coherent averaging.

Authors:  Tom Pfeiffer; Madita Göb; Wolfgang Draxinger; Sebastian Karpf; Jan Philip Kolb; Robert Huber
Journal:  Biomed Opt Express       Date:  2020-10-29       Impact factor: 3.732

6.  Volumetric non-local-means based speckle reduction for optical coherence tomography.

Authors:  Carlos Cuartas-Vélez; René Restrepo; Brett E Bouma; Néstor Uribe-Patarroyo
Journal:  Biomed Opt Express       Date:  2018-06-26       Impact factor: 3.732

7.  Complex differential variance angiography with noise-bias correction for optical coherence tomography of the retina.

Authors:  Boy Braaf; Sabine Donner; Ahhyun S Nam; Brett E Bouma; Benjamin J Vakoc
Journal:  Biomed Opt Express       Date:  2018-01-08       Impact factor: 3.732

8.  Classification of biological micro-objects using optical coherence tomography: in silico study.

Authors:  Paweł Ossowski; Maciej Wojtkowski; Peter Rt Munro
Journal:  Biomed Opt Express       Date:  2017-07-10       Impact factor: 3.732

9.  Analysis and evaluation of BC-mode OCT image visualization for microsurgery guidance.

Authors:  Shuwen Wei; Shoujing Guo; Jin U Kang
Journal:  Biomed Opt Express       Date:  2019-09-19       Impact factor: 3.732

10.  Noise characterization of supercontinuum sources for low-coherence interferometry applications.

Authors:  William J Brown; Sanghoon Kim; Adam Wax
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2014-12-01       Impact factor: 2.129

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.