Literature DB >> 23602919

Bayesian characterization of uncertainty in intra-subject non-rigid registration.

Petter Risholm1, Firdaus Janoos, Isaiah Norton, Alex J Golby, William M Wells.   

Abstract

In settings where high-level inferences are made based on registered image data, the registration uncertainty can contain important information. In this article, we propose a Bayesian non-rigid registration framework where conventional dissimilarity and regularization energies can be included in the likelihood and the prior distribution on deformations respectively through the use of Boltzmann's distribution. The posterior distribution is characterized using Markov Chain Monte Carlo (MCMC) methods with the effect of the Boltzmann temperature hyper-parameters marginalized under broad uninformative hyper-prior distributions. The MCMC chain permits estimation of the most likely deformation as well as the associated uncertainty. On synthetic examples, we demonstrate the ability of the method to identify the maximum a posteriori estimate and the associated posterior uncertainty, and demonstrate that the posterior distribution can be non-Gaussian. Additionally, results from registering clinical data acquired during neurosurgery for resection of brain tumor are provided; we compare the method to single transformation results from a deterministic optimizer and introduce methods that summarize the high-dimensional uncertainty. At the site of resection, the registration uncertainty increases and the marginal distribution on deformations is shown to be multi-modal.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23602919      PMCID: PMC3687087          DOI: 10.1016/j.media.2013.03.002

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  35 in total

1.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

2.  Characterization and propagation of uncertainty in diffusion-weighted MR imaging.

Authors:  T E J Behrens; M W Woolrich; M Jenkinson; H Johansen-Berg; R G Nunes; S Clare; P M Matthews; J M Brady; S M Smith
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

3.  Fundamental performance limits in image registration.

Authors:  Dirk Robinson; Peyman Milanfar
Journal:  IEEE Trans Image Process       Date:  2004-09       Impact factor: 10.856

4.  General approach to first-order error prediction in rigid point registration.

Authors:  Andrei Danilchenko; J Michael Fitzpatrick
Journal:  IEEE Trans Med Imaging       Date:  2010-11-11       Impact factor: 10.048

5.  Estimation of delivered dose in radiotherapy: the influence of registration uncertainty.

Authors:  Petter Risholm; James Balter; William M Wells
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

6.  Variational free energy and the Laplace approximation.

Authors:  Karl Friston; Jérémie Mattout; Nelson Trujillo-Barreto; John Ashburner; Will Penny
Journal:  Neuroimage       Date:  2006-10-20       Impact factor: 6.556

7.  Empirical Markov Chain Monte Carlo Bayesian analysis of fMRI data.

Authors:  F de Pasquale; C Del Gratta; G L Romani
Journal:  Neuroimage       Date:  2008-04-29       Impact factor: 6.556

8.  Bootstrap resampling for image registration uncertainty estimation without ground truth.

Authors:  Jan Kybic
Journal:  IEEE Trans Image Process       Date:  2010-01       Impact factor: 10.856

Review 9.  Visualizing uncertainty about the future.

Authors:  David Spiegelhalter; Mike Pearson; Ian Short
Journal:  Science       Date:  2011-09-09       Impact factor: 47.728

10.  Selection of optimal hyper-parameters for estimation of uncertainty in MRI-TRUS registration of the prostate.

Authors:  Petter Risholm; Firdaus Janoos; Jennifer Pursley; Andriy Fedorov; Clare Tempany; Robert A Cormack; William M Wells
Journal:  Med Image Comput Comput Assist Interv       Date:  2012
View more
  7 in total

1.  Consistency-based rectification of nonrigid registrations.

Authors:  Tobias Gass; Gábor Székely; Orcun Goksel
Journal:  J Med Imaging (Bellingham)       Date:  2015-03-25

2.  Application of tolerance limits to the characterization of image registration performance.

Authors:  Andriy Fedorov; William M Wells; Ron Kikinis; Clare M Tempany; Mark G Vangel
Journal:  IEEE Trans Med Imaging       Date:  2014-04-16       Impact factor: 10.048

3.  Error estimation of deformable image registration of pulmonary CT scans using convolutional neural networks.

Authors:  Koen A J Eppenhof; Josien P W Pluim
Journal:  J Med Imaging (Bellingham)       Date:  2018-05-10

4.  MRI characterization of temporal lobe epilepsy using rapidly measurable spatial indices with hemisphere asymmetries and gender features.

Authors:  Siddhartha Datta; Sudipta Sarkar; Sumit Chakraborty; Sai Krishna Mulpuru; Swadhapriya Basu; Basant K Tiwary; Nilkanta Chakrabarti; Prasun Kumar Roy
Journal:  Neuroradiology       Date:  2015-06-02       Impact factor: 2.804

5.  Unified voxel- and tensor-based morphometry (UVTBM) using registration confidence.

Authors:  Ali R Khan; Lei Wang; Mirza Faisal Beg
Journal:  Neurobiol Aging       Date:  2014-08-30       Impact factor: 4.673

6.  Validation of a nonrigid registration error detection algorithm using clinical MRI brain data.

Authors:  Ryan D Datteri; Yuan Liu; Pierre-Francois D'Haese; Benoit M Dawant
Journal:  IEEE Trans Med Imaging       Date:  2014-07-30       Impact factor: 10.048

7.  Registration quality filtering improves robustness of voxel-wise analyses to the choice of brain template.

Authors:  Nelson Gil; Michael L Lipton; Roman Fleysher
Journal:  Neuroimage       Date:  2020-12-15       Impact factor: 6.556

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.