Literature DB >> 23596052

Effect of flip angle on the accuracy and repeatability of hepatic proton density fat fraction estimation by complex data-based, T1-independent, T2*-corrected, spectrum-modeled MRI.

Benjamin L Johnson1, Michael E Schroeder, Tanya Wolfson, Anthony C Gamst, Gavin Hamilton, Masoud Shiehmorteza, Rohit Loomba, Jeffrey B Schwimmer, Scott Reeder, Michael S Middleton, Claude B Sirlin.   

Abstract

PURPOSE: To evaluate the effect of flip angle (FA) on accuracy and within-examination repeatability of hepatic proton-density fat fraction (PDFF) estimation with complex data-based magnetic resonance imaging (MRI).
MATERIALS AND METHODS: PDFF was estimated at 3T in 30 subjects using two sets of five MRI sequences with FA from 1° to 5° in each set. One set used 7 msec repetition time and acquired 6 echoes (TR7/E6); the other used 14 msec and acquired 12 echoes (TR14/E12). For each FA in both sets the accuracy of MRI-PDFF was assessed relative to MR spectroscopy (MRS)-PDFF using four regression parameters (slope, intercept, average bias, R(2) ). Each subject had four random sequences repeated; within-examination repeatability of MRI-PDFF for each FA was assessed with intraclass correlation coefficient (ICC). Pairwise comparisons were made using bootstrap-based tests.
RESULTS: Most FAs provided high MRI-PDFF estimation accuracy (intercept range -1.25 to 0.84, slope 0.89-1.06, average bias 0.24-1.65, R(2) 0.85-0.97). Most comparisons of regression parameters between FAs were not significant. Informally, in the TR7/E6 set, FAs of 2° and 3° provided the highest accuracy, while FAs of 1° and 5° provided the lowest. In the TR14/E12 set, accuracy parameters did not differ consistently between FAs. FAs in both sets provided high within-examination repeatability (ICC range 0.981-0.998).
CONCLUSION: MRI-PDFF was repeatable and, for most FAs, accurate in both sequence sets. In the TR7/E6 sequence set, FAs of 2° and 3° informally provided the highest accuracy. In the TR14/E12 sequence set, all FAs provided similar accuracy.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  accuracy; flip angle; magnetic resonance imaging; proton-density fat fraction; repeatability

Mesh:

Substances:

Year:  2013        PMID: 23596052      PMCID: PMC3732566          DOI: 10.1002/jmri.24153

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  20 in total

1.  Java-based graphical user interface for MRUI, a software package for quantitation of in vivo/medical magnetic resonance spectroscopy signals.

Authors:  A Naressi; C Couturier; I Castang; R de Beer; D Graveron-Demilly
Journal:  Comput Biol Med       Date:  2001-07       Impact factor: 4.589

2.  Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging.

Authors:  Scott B Reeder; Angel R Pineda; Zhifei Wen; Ann Shimakawa; Huanzhou Yu; Jean H Brittain; Garry E Gold; Christopher H Beaulieu; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

3.  Fat quantification with IDEAL gradient echo imaging: correction of bias from T(1) and noise.

Authors:  Chia-Ying Liu; Charles A McKenzie; Huanzhou Yu; Jean H Brittain; Scott B Reeder
Journal:  Magn Reson Med       Date:  2007-08       Impact factor: 4.668

4.  Optimal phased-array combination for spectroscopy.

Authors:  Mark Bydder; Gavin Hamilton; Takeshi Yokoo; Claude B Sirlin
Journal:  Magn Reson Imaging       Date:  2008-05-16       Impact factor: 2.546

5.  Improved method for accurate and efficient quantification of MRS data with use of prior knowledge

Authors: 
Journal:  J Magn Reson       Date:  1997-11       Impact factor: 2.229

6.  T(1) independent, T(2) (*) corrected chemical shift based fat-water separation with multi-peak fat spectral modeling is an accurate and precise measure of hepatic steatosis.

Authors:  Catherine D G Hines; Alex Frydrychowicz; Gavin Hamilton; Dana L Tudorascu; Karl K Vigen; Huanzhou Yu; Charles A McKenzie; Claude B Sirlin; Jean H Brittain; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

7.  Magnetic resonance imaging: effects of magnetic field strength.

Authors:  L E Crooks; M Arakawa; J Hoenninger; B McCarten; J Watts; L Kaufman
Journal:  Radiology       Date:  1984-04       Impact factor: 11.105

8.  Water-fat separation with IDEAL gradient-echo imaging.

Authors:  Scott B Reeder; Charles A McKenzie; Angel R Pineda; Huanzhou Yu; Ann Shimakawa; Anja C Brau; Brian A Hargreaves; Garry E Gold; Jean H Brittain
Journal:  J Magn Reson Imaging       Date:  2007-03       Impact factor: 4.813

9.  Multiecho reconstruction for simultaneous water-fat decomposition and T2* estimation.

Authors:  Huanzhou Yu; Charles A McKenzie; Ann Shimakawa; Anthony T Vu; Anja C S Brau; Philip J Beatty; Angel R Pineda; Jean H Brittain; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2007-10       Impact factor: 4.813

10.  T1 independent, T2* corrected MRI with accurate spectral modeling for quantification of fat: validation in a fat-water-SPIO phantom.

Authors:  Catherine D G Hines; Huanzhou Yu; Ann Shimakawa; Charles A McKenzie; Jean H Brittain; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

View more
  22 in total

1.  Measurement of spleen fat on MRI-proton density fat fraction arises from reconstruction of noise.

Authors:  Cheng William Hong; Gavin Hamilton; Catherine Hooker; Charlie C Park; Calvin Andrew Tran; Walter C Henderson; Jonathan C Hooker; Soudabeh Fazeli Dehkordy; Jeffrey B Schwimmer; Scott B Reeder; Claude B Sirlin
Journal:  Abdom Radiol (NY)       Date:  2019-10

2.  Accuracy of multiecho magnitude-based MRI (M-MRI) for estimation of hepatic proton density fat fraction (PDFF) in children.

Authors:  Kevin A Zand; Amol Shah; Elhamy Heba; Tanya Wolfson; Gavin Hamilton; Jessica Lam; Joshua Chen; Jonathan C Hooker; Anthony C Gamst; Michael S Middleton; Jeffrey B Schwimmer; Claude B Sirlin
Journal:  J Magn Reson Imaging       Date:  2015-04-03       Impact factor: 4.813

3.  Bone marrow fat content is correlated with hepatic fat content in paediatric non-alcoholic fatty liver disease.

Authors:  N Y Yu; T Wolfson; M S Middleton; G Hamilton; A Gamst; J E Angeles; J B Schwimmer; C B Sirlin
Journal:  Clin Radiol       Date:  2017-01-05       Impact factor: 2.350

Review 4.  Fat Quantification in the Abdomen.

Authors:  Cheng William Hong; Soudabeh Fazeli Dehkordy; Jonathan C Hooker; Gavin Hamilton; Claude B Sirlin
Journal:  Top Magn Reson Imaging       Date:  2017-12

5.  Reproducibility of MR-based liver fat quantification across field strength: Same-day comparison between 1.5T and 3T in obese subjects.

Authors:  Nathan S Artz; William M Haufe; Catherine A Hooker; Gavin Hamilton; Tanya Wolfson; Guilherme M Campos; Anthony C Gamst; Jeffrey B Schwimmer; Claude B Sirlin; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2015-01-23       Impact factor: 4.813

Review 6.  Linearity, Bias, and Precision of Hepatic Proton Density Fat Fraction Measurements by Using MR Imaging: A Meta-Analysis.

Authors:  Takeshi Yokoo; Suraj D Serai; Ali Pirasteh; Mustafa R Bashir; Gavin Hamilton; Diego Hernando; Houchun H Hu; Holger Hetterich; Jens-Peter Kühn; Guido M Kukuk; Rohit Loomba; Michael S Middleton; Nancy A Obuchowski; Ji Soo Song; An Tang; Xinhuai Wu; Scott B Reeder; Claude B Sirlin
Journal:  Radiology       Date:  2017-09-11       Impact factor: 11.105

7.  Intra- and inter-examination repeatability of magnetic resonance spectroscopy, magnitude-based MRI, and complex-based MRI for estimation of hepatic proton density fat fraction in overweight and obese children and adults.

Authors:  Avishkar Tyagi; Omid Yeganeh; Yakir Levin; Jonathan C Hooker; Gavin C Hamilton; Tanya Wolfson; Anthony Gamst; Amir K Zand; Elhamy Heba; Rohit Loomba; Jeffrey Schwimmer; Michael S Middleton; Claude B Sirlin
Journal:  Abdom Imaging       Date:  2015-10

8.  Prospective comparison of longitudinal change in hepatic proton density fat fraction (PDFF) estimated by magnitude-based MRI (MRI-M) and complex-based MRI (MRI-C).

Authors:  Adrija Mamidipalli; Kathryn J Fowler; Gavin Hamilton; Tanya Wolfson; Yesenia Covarrubias; Calvin Tran; Soudabeh Fazeli; Curtis N Wiens; Alan McMillan; Nathan S Artz; Luke M Funk; Guilherme M Campos; Jacob A Greenberg; Anthony Gamst; Michael S Middleton; Jeffrey B Schwimmer; Scott B Reeder; Claude B Sirlin
Journal:  Eur Radiol       Date:  2020-04-21       Impact factor: 5.315

9.  Accuracy of PDFF estimation by magnitude-based and complex-based MRI in children with MR spectroscopy as a reference.

Authors:  William M Haufe; Tanya Wolfson; Catherine A Hooker; Jonathan C Hooker; Yesenia Covarrubias; Alex N Schlein; Gavin Hamilton; Michael S Middleton; Jorge E Angeles; Diego Hernando; Scott B Reeder; Jeffrey B Schwimmer; Claude B Sirlin
Journal:  J Magn Reson Imaging       Date:  2017-03-21       Impact factor: 4.813

10.  Pilot study on longitudinal change in pancreatic proton density fat fraction during a weight-loss surgery program in adults with obesity.

Authors:  Yesenia Covarrubias; Kathryn J Fowler; Adrija Mamidipalli; Gavin Hamilton; Tanya Wolfson; Olof Dahlqvist Leinhard; Garth Jacobsen; Santiago Horgan; Jeffrey B Schwimmer; Scott B Reeder; Claude B Sirlin
Journal:  J Magn Reson Imaging       Date:  2019-01-30       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.