Accuracy of off-line bioluminescence imaging to localize targets in preclinical radiation research.

Richard Tuli1, Michael Armour, Andrew Surmak, Juvenal Reyes, Iulian Iordachita, Michael Patterson, John Wong.   

Abstract

In this study, we investigated the accuracy of using off-line bioluminescence imaging (BLI) and tomography (BLT) to guide irradiation of small soft tissue targets on a small animal radiation research platform (SARRP) with on-board cone beam CT (CBCT) capability. A small glass bulb containing BL cells was implanted as a BL source in the abdomen of 11 mouse carcasses. Bioluminescence imaging and tomography were acquired for each carcass. Six carcasses were setup visually without immobilization and 5 were restrained in position with tape. All carcasses were setup in treatment position on the SARRP where the centroid position of the bulb on CBCT was taken as "truth". In the 2D visual setup, the carcass was setup by aligning the point of brightest luminescence with the vertical beam axis. In the CBCT assisted setup, the pose of the carcass on CBCT was aligned with that on the 2D BL image for setup. For both 2D setup methods, the offset of the bulb centroid on CBCT from the vertical beam axis was measured. In the BLT-CBCT fusion method, the 3D torso on BLT and CBCT was registered and the 3D offset of the respective source centroids was calculated. The setup results were independent of the carcass being immobilized or not due to the onset of rigor mortis. The 2D offset of the perceived BL source position from the CBCT bulb position was 2.3 mm ± 1.3 mm. The 3D offset between BLT and CBCT was 1.5 mm ± 0.9 mm. Given the rigidity of the carcasses, the setup results represent the best that can be achieved with off-line 2D BLI and 3D BLT. The setup uncertainty would require the use of undesirably large margin of 4-5 mm. The results compel the implementation of on-board BLT capability on the SARRP to eliminate setup error and to improve BLT accuracy.

Entities:  

Mesh:

Year:  2013        PMID: 23578189      PMCID: PMC4347528          DOI: 10.1667/RR2999.2

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  10 in total

1.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy.

Authors:  M van Herk; P Remeijer; C Rasch; J V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-07-01       Impact factor: 7.038

2.  Validation of luminescent source reconstruction using single-view spectrally resolved bioluminescence images.

Authors:  John Virostko; Alvin C Powers; E Duco Jansen
Journal:  Appl Opt       Date:  2007-05-01       Impact factor: 1.980

3.  Precision radiotherapy for small animal research.

Authors:  Mohammad Matinfar; Iulian Iordachita; Eric Ford; John Wong; Peter Kazanzides
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

4.  Irradiation induces bone injury by damaging bone marrow microenvironment for stem cells.

Authors:  Xu Cao; Xiangwei Wu; Deborah Frassica; Bing Yu; Lijuan Pang; Lingling Xian; Mei Wan; Weiqi Lei; Michael Armour; Erik Tryggestad; John Wong; Chun Yi Wen; William Weijia Lu; Frank J Frassica
Journal:  Proc Natl Acad Sci U S A       Date:  2011-01-10       Impact factor: 11.205

5.  Localized CT-guided irradiation inhibits neurogenesis in specific regions of the adult mouse brain.

Authors:  E C Ford; P Achanta; D Purger; M Armour; J Reyes; J Fong; L Kleinberg; K Redmond; J Wong; M H Jang; H Jun; H-J Song; A Quinones-Hinojosa
Journal:  Radiat Res       Date:  2011-03-30       Impact factor: 2.841

6.  Transforming growth factor-beta-mediated chondrogenesis of human mesenchymal progenitor cells involves N-cadherin and mitogen-activated protein kinase and Wnt signaling cross-talk.

Authors:  Richard Tuli; Suraj Tuli; Sumon Nandi; Xiaoxue Huang; Paul A Manner; William J Hozack; Keith G Danielson; David J Hall; Rocky S Tuan
Journal:  J Biol Chem       Date:  2003-07-31       Impact factor: 5.157

7.  A new liposomal formulation of Gemcitabine is active in an orthotopic mouse model of pancreatic cancer accessible to bioluminescence imaging.

Authors:  C Bornmann; R Graeser; N Esser; V Ziroli; P Jantscheff; T Keck; C Unger; U T Hopt; U Adam; C Schaechtele; U Massing; E von Dobschuetz
Journal:  Cancer Chemother Pharmacol       Date:  2007-06-07       Impact factor: 3.333

8.  CT guidance is needed to achieve reproducible positioning of the mouse head for repeat precision cranial irradiation.

Authors:  M Armour; E Ford; I Iordachita; J Wong
Journal:  Radiat Res       Date:  2010-01       Impact factor: 2.841

9.  High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities.

Authors:  John Wong; Elwood Armour; Peter Kazanzides; Iulian Iordachita; Erik Tryggestad; Hua Deng; Mohammad Matinfar; Christopher Kennedy; Zejian Liu; Timothy Chan; Owen Gray; Frank Verhaegen; Todd McNutt; Eric Ford; Theodore L DeWeese
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-08-01       Impact factor: 7.038

10.  Differentiation between glioma and radiation necrosis using molecular magnetic resonance imaging of endogenous proteins and peptides.

Authors:  Jinyuan Zhou; Erik Tryggestad; Zhibo Wen; Bachchu Lal; Tingting Zhou; Rachel Grossman; Silun Wang; Kun Yan; De-Xue Fu; Eric Ford; Betty Tyler; Jaishri Blakeley; John Laterra; Peter C M van Zijl
Journal:  Nat Med       Date:  2010-12-19       Impact factor: 53.440

  10 in total
  7 in total

1.  MRI-guided 3D conformal arc micro-irradiation of a F98 glioblastoma rat model using the Small Animal Radiation Research Platform (SARRP).

Authors:  Julie Bolcaen; Benedicte Descamps; Karel Deblaere; Tom Boterberg; Giorgio Hallaert; Caroline Van den Broecke; Elke Decrock; Anne Vral; Luc Leybaert; Christian Vanhove; Ingeborg Goethals
Journal:  J Neurooncol       Date:  2014-07-29       Impact factor: 4.130

2.  Systematic study of target localization for bioluminescence tomography guided radiation therapy.

Authors:  Jingjing Yu; Bin Zhang; Iulian I Iordachita; Juvenal Reyes; Zhihao Lu; Malcolm V Brock; Michael S Patterson; John W Wong; Ken Kang-Hsin Wang
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

3.  Bioluminescence Tomography-Guided Radiation Therapy for Preclinical Research.

Authors:  Bin Zhang; Ken Kang-Hsin Wang; Jingjing Yu; Sohrab Eslami; Iulian Iordachita; Juvenal Reyes; Reem Malek; Phuoc T Tran; Michael S Patterson; John W Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-12-14       Impact factor: 7.038

4.  Evaluation of On- and Off-Line Bioluminescence Tomography System for Focal Irradiation Guidance.

Authors:  Bin Zhang; John W Wong; Iulian I Iordachita; Juvenal Reyes; Katriana Nugent; Phuoc T Tran; Stephen W Tuttle; Constantinos Koumenis; Ken Kang-Hsin Wang
Journal:  Radiat Res       Date:  2016-11-21       Impact factor: 2.841

5.  Mobile bioluminescence tomography-guided system for pre-clinical radiotherapy research.

Authors:  Zijian Deng; Xiangkun Xu; Iulian Iordachita; Hamid Dehghani; Bin Zhang; John W Wong; Ken Kang-Hsin Wang
Journal:  Biomed Opt Express       Date:  2022-08-30       Impact factor: 3.562

6.  Translation of DNA Damage Response Inhibitors as Chemoradiation Sensitizers From the Laboratory to the Clinic.

Authors:  Leslie A Parsels; Qiang Zhang; David Karnak; Joshua D Parsels; Kwok Lam; Henning Willers; Michael D Green; Alnawaz Rehemtulla; Theodore S Lawrence; Meredith A Morgan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2021-08-01       Impact factor: 7.038

7.  Radiosensitization of Pancreatic Cancer Cells In Vitro and In Vivo through Poly (ADP-ribose) Polymerase Inhibition with ABT-888.

Authors:  Richard Tuli; Andrew J Surmak; Juvenal Reyes; Michael Armour; Amy Hacker-Prietz; John Wong; Theodore L DeWeese; Joseph M Herman
Journal:  Transl Oncol       Date:  2014-05-13       Impact factor: 4.243

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.