Literature DB >> 23571836

QRS morphology, left ventricular lead location, and clinical outcome in patients receiving cardiac resynchronization therapy.

Jagdesh Kandala1, Gaurav A Upadhyay, Robert K Altman, Kimberly A Parks, Mary Orencole, Theofanie Mela, E Kevin Heist, Jagmeet P Singh.   

Abstract

AIMS: Several studies have reported a poor outcome with cardiac resynchronization therapy (CRT) in non-left bundle branch block (LBBB) patients. Although the left ventricular (LV) lead location is an important determinant of the clinical outcome, there is scant information regarding its role in non-LBBB patients. This study sought to examine the impact of electrical and anatomical location of the LV lead in relation to baseline QRS morphology on the CRT outcome. METHODS AND
RESULTS: A left ventricular lead electrical delay (LVLED) was measured intra-procedurally as an interval between QRS onset on the surface electrocardiogram (ECG) to the peak of sensed electrogram on LV lead and corrected for QRS width. The impact of the LVLED on time to first heart failure hospitalization (HFH), and composite outcome of all-cause mortality, HFH, LVAD implantation, and cardiac transplantation at 3 years was assessed. Among 144 patients (age 67 ± 12 years, QRS duration 156 ± 28 ms, non-LBBB 43%), HFH was higher in non-LBBB compared with LBBB (43.5 vs. 24%, P = 0.015). Within LBBB, patients with the long LVLED (≥50%) had 17% HFH vs. 53% in the short LVLED (<50%), P = 0.002. Likewise in non-LBBB, patients with the long LVLED compared with the short LVLED had a lower HFH (36 vs. 61%, P = 0.026). In adjusted Cox proportional hazards model, the long LVLED in LBBB and non-LBBB was associated with an improved outcome. Specifically, in non-LBBB, LVLED ≥50% was associated with improved event-free survival with respect to time to first HFH (HR: 0.34; P = 0.011) and composite outcome (HR: 0.41; P = 0.019).
CONCLUSION: Cardiac resynchronization therapy delivered from an LV pacing site characterized by the long LVLED was associated with the favourable outcome in LBBB and non-LBBB patients.

Entities:  

Keywords:  Cardiac resynchronization therapy; Electrical delay; Left ventricular lead location; QRS morphology

Mesh:

Year:  2013        PMID: 23571836     DOI: 10.1093/eurheartj/eht123

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  14 in total

Review 1.  Roles and indications for use of implantable defibrillator and resynchronization therapy in the prevention of sudden cardiac death in heart failure.

Authors:  Yitschak Biton; Jayson R Baman; Bronislava Polonsky
Journal:  Heart Fail Rev       Date:  2016-07       Impact factor: 4.214

Review 2.  [Multipoint pacing-more CRT or a waste of battery power?]

Authors:  J Müller-Leisse; C Zormpas; T König; D Duncker; C Veltmann
Journal:  Herz       Date:  2018-11       Impact factor: 1.443

3.  Non-invasively quantified changes in left ventricular activation predict outcomes in patients undergoing cardiac resynchronization therapy.

Authors:  Daniel J Friedman; Kasper Emerek; Steen Møller Hansen; Christoffer Polcwiartek; Peter L Sørensen; Zak Loring; Joanne Sutter; Peter Søgaard; Joseph Kisslo; Claus Graff; Brett D Atwater
Journal:  J Cardiovasc Electrophysiol       Date:  2019-10-08

Review 4.  Routine Implant of Biventricular Devices Guided by an Electroanatomic Mapping System - Ready for Prime-Time?

Authors:  Kim H Chan; Peter A Santucci
Journal:  J Atr Fibrillation       Date:  2015-12-31

5.  Characteristics of the electrocardiogram in patients with continuous-flow left ventricular assist devices.

Authors:  Sara C Martinez; Derrick Fansler; Jeffrey Lau; Eric L Novak; Susan M Joseph; Robert E Kleiger
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-07-07       Impact factor: 1.468

Review 6.  Does Cardiac Resynchronization Therapy Benefit Patients with Non-Left Bundle Branch Block Prolonged QRS Patterns?

Authors:  Mark N Belkin; Gaurav A Upadhyay
Journal:  Curr Cardiol Rep       Date:  2017-10-24       Impact factor: 2.931

Review 7.  Strategies to improve cardiac resynchronization therapy.

Authors:  Kevin Vernooy; Caroline J M van Deursen; Marc Strik; Frits W Prinzen
Journal:  Nat Rev Cardiol       Date:  2014-05-20       Impact factor: 32.419

8.  Wideband LGE MRI permits unobstructed viewing of myocardial scarring in a patient with an MR-conditional subcutaneous implantable cardioverter-defibrillator.

Authors:  Amir Ali Rahsepar; Jeremy D Collins; Bradley P Knight; KyungPyo Hong; James C Carr; Daniel Kim
Journal:  Clin Imaging       Date:  2018-05-04       Impact factor: 1.605

9.  Predictors of Total Mortality and Echocardiographic Response for Cardiac Resynchronization Therapy: A Cohort Study.

Authors:  Guilherme Ferreira Gazzoni; Matheus Bom Fraga; Andres Di Leoni Ferrari; Pablo da Costa Soliz; Anibal Pires Borges; Eduardo Bartholomay; Carlos Antonio Abunader Kalil; Vanessa Giaretta; Luis Eduardo Paim Rohde
Journal:  Arq Bras Cardiol       Date:  2017-11-27       Impact factor: 2.000

10.  Identifying delayed left ventricular lateral wall activation in patients with non-specific intraventricular conduction delay using coronary venous electroanatomical mapping.

Authors:  A M W van Stipdonk; M Mafi Rad; J G L M Luermans; H J Crijns; F W Prinzen; K Vernooy
Journal:  Neth Heart J       Date:  2016-01       Impact factor: 2.380

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.