BACKGROUND: In laparoscopic incisional hernia repair, direct contact between the prosthesis and the abdominal viscera is inevitable, which may lead to an inflammatory reaction resulting in abdominal adhesion formation. This study compared five different synthetic and biologic meshes in terms of adhesion formation, shrinkage, incorporation, and histologic characteristics after a period of 30 and 90 days. METHODS: In 85 rats, a mesh was positioned intraperitoneally in direct contact with the viscera. Five different meshes were implanted: Prolene (polypropylene), Parietex composite (collagen-coated polyester), Strattice (porcine dermis, non-cross-linked), Surgisis (porcine small intestine submucosa, non-cross-linked), and Permacol (porcine dermis, cross-linked). The meshes were tested in terms of adhesion formation, shrinkage, and incorporation after a period of 30 and 90 days. Additionally, collagen formation after 90 days was determined. RESULTS: Significantly less adhesion formation was observed with Parietex composite (5 %; interquartile range [IQR], 2-5 %) and Strattice (5 %; IQR, 4-10 %) in the long term. In contrast, organs were attached to Permacol with four of seven meshes (57 %), and adhesion coverage of Surgisis mesh was present in 66 % (IQR, 0-100 %) of the cases. After 90 days, the best incorporation was seen with the Parietex composite mesh (79 %; IQR, 61-83 %). After 90 days, major alterations in adhesion formation were seen compared with 30 days. Histologically, Strattice and Parietex composite showed a new mesothelial layer on the visceral side of the mesh. Microscopic degradation and new collagen formation were seen in the Surgisis group. CONCLUSIONS: Parietex composite mesh demonstrated the best long-term results compared with all the other meshes. The biologic non-cross-linked mesh, Strattice, showed little adhesion formation and moderate shrinkage but poor incorporation. Biologic meshes are promising, but varying results require a more detailed investigation and demonstrate that biologic meshes are not necessarily superior to synthetic meshes. The significant changes that take place between 30 and 90 days should lead to careful interpretation of short-term experimental results.
BACKGROUND: In laparoscopic incisional hernia repair, direct contact between the prosthesis and the abdominal viscera is inevitable, which may lead to an inflammatory reaction resulting in abdominal adhesion formation. This study compared five different synthetic and biologic meshes in terms of adhesion formation, shrinkage, incorporation, and histologic characteristics after a period of 30 and 90 days. METHODS: In 85 rats, a mesh was positioned intraperitoneally in direct contact with the viscera. Five different meshes were implanted: Prolene (polypropylene), Parietex composite (collagen-coated polyester), Strattice (porcine dermis, non-cross-linked), Surgisis (porcine small intestine submucosa, non-cross-linked), and Permacol (porcine dermis, cross-linked). The meshes were tested in terms of adhesion formation, shrinkage, and incorporation after a period of 30 and 90 days. Additionally, collagen formation after 90 days was determined. RESULTS: Significantly less adhesion formation was observed with Parietex composite (5 %; interquartile range [IQR], 2-5 %) and Strattice (5 %; IQR, 4-10 %) in the long term. In contrast, organs were attached to Permacol with four of seven meshes (57 %), and adhesion coverage of Surgisis mesh was present in 66 % (IQR, 0-100 %) of the cases. After 90 days, the best incorporation was seen with the Parietex composite mesh (79 %; IQR, 61-83 %). After 90 days, major alterations in adhesion formation were seen compared with 30 days. Histologically, Strattice and Parietex composite showed a new mesothelial layer on the visceral side of the mesh. Microscopic degradation and new collagen formation were seen in the Surgisis group. CONCLUSIONS: Parietex composite mesh demonstrated the best long-term results compared with all the other meshes. The biologic non-cross-linked mesh, Strattice, showed little adhesion formation and moderate shrinkage but poor incorporation. Biologic meshes are promising, but varying results require a more detailed investigation and demonstrate that biologic meshes are not necessarily superior to synthetic meshes. The significant changes that take place between 30 and 90 days should lead to careful interpretation of short-term experimental results.
Authors: Matthew G Stanwix; Arthur J Nam; Helen G Hui-Chou; Jonathan P Ferrari; Harold M Aberman; Michael L Hawes; Kaspar M Keledjian; Luke S Jones; Eduardo D Rodriguez Journal: Ann Plast Surg Date: 2011-04 Impact factor: 1.539
Authors: Jacobus W A Burger; Roland W Luijendijk; Wim C J Hop; Jens A Halm; Emiel G G Verdaasdonk; Johannes Jeekel Journal: Ann Surg Date: 2004-10 Impact factor: 12.969
Authors: Ali Rastegarpour; Michael Cheung; Madhurima Vardhan; Mohamed M Ibrahim; Charles E Butler; Howard Levinson Journal: Plast Surg (Oakv) Date: 2016 Impact factor: 0.947
Authors: Yohann Renard; Louis de Mestier; Julie Henriques; Paul de Boissieu; Philippe de Mestier; Abe Fingerhut; Jean-Pierre Palot; Reza Kianmanesh Journal: J Gastrointest Surg Date: 2019-01-22 Impact factor: 3.452
Authors: Kevin W Y van Barneveld; Ruben R M Vogels; Geerard L Beets; Stephanie O Breukink; Jan-Willem M Greve; Nicole D Bouvy; Marc H F Schreinemacher Journal: Surg Endosc Date: 2013-12-20 Impact factor: 4.584
Authors: M P Morris; J A Mellia; A N Christopher; M N Basta; V Patel; K Qiu; R B Broach; J P Fischer Journal: Hernia Date: 2021-01-19 Impact factor: 4.739
Authors: William C Cole; Eric M Balent; Pamela C Masella; Lauren N Kajiura; Karen W Matsumoto; Lisa M Pierce Journal: Hernia Date: 2014-08-01 Impact factor: 4.739
Authors: Job C Tharappel; Jennifer W Harris; Crystal Totten; Brittany A Zwischenberger; John S Roth Journal: Surg Endosc Date: 2016-08-12 Impact factor: 4.584
Authors: Erik T Criman; Wendy E Kurata; Karen W Matsumoto; Harry T Aubin; Carmen E Campbell; Lisa M Pierce Journal: Plast Reconstr Surg Glob Open Date: 2016-06-17