Literature DB >> 25294530

Imaging visceral adhesion to polymeric mesh using pneumoperitoneal-MRI in an experimental rat model.

Florence Franconi1, Jérome Roux, Céline Lefebvre-Lacoeuille, Laurent Lemaire.   

Abstract

BACKGROUND: Intraperitoneal mesh implantation is often associated with formation of adhesion to the mesh. This experimental study examines the potential of minimally invasive pneumoperitoneal-MRI to assess these adhesions in a preclinical context.
METHODS: Uncoated polyethylene terephthalate meshes were placed intraperitoneally in rats, in regard to the caecum previously scraped to promote petechial bleeding and subsequent adhesions. Examinations were performed 2-weeks post mesh implantation using a rodent dedicated high field MRI. Respiratory-triggered T2-weighted images were acquired prior to and after intraperitoneal injection of ~8-10 mL gas to induce a mechanical stress on the abdominal wall.
RESULTS: Adhesions are occasionally seen in sham-operated rats as opposed to rats receiving polyethylene terephthalate meshes. On high-resolution images, meshes can be detected due to their characteristic net shape. However, evidence of adherence is only found if intraperitoneal gas injection is performed, when a ~1-cm elevation of the abdominal wall is observed. When adherence occurs between the mesh and the caecum, the latter remains in contact with the wall. Looser adherences between visceral tissue and meshes are also observed.
CONCLUSIONS: T2-weighted pneumoperitoneal-MRI is a powerful tool for assessing adherence after intraperitoneal mesh implantation. According to the mini-invasive procedure adopted here, this approach may allow a temporal follow-up of adherence fate.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25294530     DOI: 10.1007/s00464-014-3843-9

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  25 in total

1.  A concept for magnetic resonance visualization of surgical textile implants.

Authors:  Nils A Krämer; Hank C W Donker; Jens Otto; Michael Hodenius; Julien Sénégas; Ioana Slabu; Uwe Klinge; Martin Baumann; Andreas Müllen; Boris Obolenski; Rolf W Günther; Gabriele A Krombach
Journal:  Invest Radiol       Date:  2010-08       Impact factor: 6.016

2.  Addition of nitrous oxide to the carbon dioxide pneumoperitoneum strongly decreases adhesion formation and the dose-dependent adhesiogenic effect of blood in a laparoscopic mouse model.

Authors:  Roberta Corona; Maria Mercedes Binda; Karina Mailova; Jasper Verguts; Philippe R Koninckx
Journal:  Fertil Steril       Date:  2013-10-07       Impact factor: 7.329

3.  New magnetic-resonance-imaging-visible poly(ε-caprolactone)-based polyester for biomedical applications.

Authors:  Sebastien Blanquer; Olivier Guillaume; Vincent Letouzey; Laurent Lemaire; Florence Franconi; Cedric Paniagua; Jean Coudane; Xavier Garric
Journal:  Acta Biomater       Date:  2011-11-11       Impact factor: 8.947

4.  Cine magnetic resonance imaging vs high-resolution ultrasonography for detection of adhesions after laparoscopic and open incisional hernia repair: a matched pair pilot analysis.

Authors:  T Mussack; T Fischer; R Ladurner; A Gangkofer; S Bensler; K K Hallfeldt; M Reiser; A Lienemann
Journal:  Surg Endosc       Date:  2005-10-24       Impact factor: 4.584

5.  Anterior abdominal wall adhesions after laparotomy or laparoscopy.

Authors:  S G Levrant; E J Bieber; R B Barnes
Journal:  J Am Assoc Gynecol Laparosc       Date:  1997-05

6.  Coated meshes for hernia repair provide comparable intraperitoneal adhesion prevention.

Authors:  Marc H F Schreinemacher; Kevin W Y van Barneveld; Rieky E G Dikmans; Marion J J Gijbels; Jan-Willem M Greve; Nicole D Bouvy
Journal:  Surg Endosc       Date:  2013-06-08       Impact factor: 4.584

7.  Detection of abdominal wall adhesions using visceral slide.

Authors:  Nellie Bering Zinther; Anna Zeuten; Edvard Marinovskij; Margit Haislund; Hans Friis-Andersen
Journal:  Surg Endosc       Date:  2010-05-20       Impact factor: 4.584

8.  Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia.

Authors:  Jacobus W A Burger; Roland W Luijendijk; Wim C J Hop; Jens A Halm; Emiel G G Verdaasdonk; Johannes Jeekel
Journal:  Ann Surg       Date:  2004-10       Impact factor: 12.969

9.  Analysis of the kinetics of peritoneal adhesion formation in the rat and evaluation of potential antiadhesive agents.

Authors:  E S Harris; R F Morgan; G T Rodeheaver
Journal:  Surgery       Date:  1995-06       Impact factor: 3.982

10.  In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides.

Authors:  Nicolas Kuehnert; Nils A Kraemer; Jens Otto; Hank C W Donker; Ioana Slabu; Martin Baumann; Christiane K Kuhl; Uwe Klinge
Journal:  Surg Endosc       Date:  2011-12-17       Impact factor: 4.584

View more
  2 in total

1.  Can magnetisation transfer magnetic resonance imaging help for the follow-up of synthetic hernia composite meshes fate? A pilot study.

Authors:  Florence Franconi; Olivier Lefranc; Amandine Radlovic; Laurent Lemaire
Journal:  MAGMA       Date:  2022-05-13       Impact factor: 2.310

2.  Impairment of the Peritoneal Surface as a Decisive Factor for Intestinal Adhesions in Intraperitoneal Onlay Mesh Surgery - Introducing a New Rat Model.

Authors:  M Winny; L Grethe; L Maegel; D Jonigk; T Lippmann; J Klempnauer; D Poehnert
Journal:  Int J Med Sci       Date:  2016-02-01       Impact factor: 3.738

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.