| Literature DB >> 23531499 |
Sandesh Gulhane1, Ian Holloway, Mathew Bartlett.
Abstract
The use of computer navigation has the potential to improve implant position in total knee arthroplasty (TKA), but pin fixation of reference arrays introduces an additional potential source of complications. We report a case of vascular injury related to the insertion of a femoral pin during navigated TKA.Entities:
Keywords: Navigated knee arthroplasty; total knee arthroplasty; vascular complications
Year: 2013 PMID: 23531499 PMCID: PMC3601244 DOI: 10.4103/0019-5413.106927
Source DB: PubMed Journal: Indian J Orthop ISSN: 0019-5413 Impact factor: 1.251
Figure 1Peroperative photographs (a) Insertion of tibial and femoral reference arrays (b) The styloid used to map out the tibia and femur
Figure 2Two CT scan images showing active bleeding into the femoral canal
Figure 3Final followup X-ray showing insertion of two unicortical screws