Literature DB >> 16260662

Blood loss after total knee replacement: effects of computer-assisted surgery.

Y Kalairajah1, D Simpson, A J Cossey, G M Verrall, A J Spriggins.   

Abstract

We carried out a prospective randomised study to evaluate the blood loss in 60 patients having a total knee arthroplasty and divided randomly into two equal groups, one having a computer-assisted procedure and the other a standard operation. The surgery was carried out by a single surgeon at one institution using a uniform approach. The only variable in the groups was the use of intramedullary femoral and tibial alignment jigs in the standard group and single tracker pins of the imageless navigation system in the tibia and femur in the navigated group. The mean drainage of blood was 1351 ml (715 to 2890; 95% confidence interval (CI) 1183 to 1518) in the computer-aided group and 1747 ml (1100 to 3030; CI 1581 to 1912) in the conventional group. This difference was statistically significant (p = 0.001). The mean calculated loss of haemoglobin was 36 g/dl in the navigated group versus 53 g/dl in the conventional group; this was significant at p < 0.00001. There was a highly significant reduction in blood drainage and the calculated Hb loss between the computer-assisted and the conventional techniques. This allows the ordering of less blood before the operation, reduces risks at transfusion and gives financial saving. Computer-assisted surgery may also be useful for patients in whom blood products are not acceptable.

Entities:  

Mesh:

Year:  2005        PMID: 16260662     DOI: 10.1302/0301-620X.87B11.16474

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  57 in total

Review 1.  Computer assisted navigation in knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song
Journal:  Clin Orthop Surg       Date:  2011-12-01

2.  Shed blood re-transfusion provides no benefit in computer-assisted primary total knee arthroplasty.

Authors:  Dae-Hee Lee; Debabrata Padhy; Soon-Hyuck Lee; Tae-Kwon Kim; Jungsoon Choi; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-03       Impact factor: 4.342

3.  The comparative efficacies of intra-articular and IV tranexamic acid for reducing blood loss during total knee arthroplasty.

Authors:  Jai-Gon Seo; Young-Wan Moon; Sang-Hoon Park; Sang-Min Kim; Kyung-Rae Ko
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-24       Impact factor: 4.342

4.  Does tranexamic acid save blood in minimally invasive total knee arthroplasty?

Authors:  Po-Chun Lin; Chi-Hsiang Hsu; Wun-Schen Chen; Jun-Wen Wang
Journal:  Clin Orthop Relat Res       Date:  2011-02-01       Impact factor: 4.176

5.  Intra-operative tibial fracture during computer assisted total knee replacement: a case report.

Authors:  A Manzotti; N Confalonieri; C Pullen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-05       Impact factor: 4.342

6.  Comment on Dattani et al: Navigation knee replacement.

Authors:  C Schnurr; D P König
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

7.  Computer-assisted surgery can reduce blood loss after total knee arthroplasty.

Authors:  Pedro Hinarejos; Mónica Corrales; Antonia Matamalas; Elvira Bisbe; Enric Cáceres
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-16       Impact factor: 4.342

Review 8.  Total joint replacement and blood loss: what is the best equation?

Authors:  Emmanuel Gibon; Jean-Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2013-02-06       Impact factor: 3.075

9.  The reduction in blood loss with intra-articular injection of tranexamic acid in unilateral total knee arthroplasty without operative drains: a randomized controlled trial.

Authors:  Yang Yang; Yong-Ming Lv; Pei-Jian Ding; Jia Li; Zhang Ying-Ze
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-05-10

10.  Comparision of blood loss between computer assisted and conventional total knee arthroplasty.

Authors:  Paras Kumar Mohanlal; Nemandra Sandiford; John A Skinner; Sr Samsani
Journal:  Indian J Orthop       Date:  2013-01       Impact factor: 1.251

View more