Literature DB >> 23518146

Metal artifacts reduction using monochromatic images from spectral CT: evaluation of pedicle screws in patients with scoliosis.

Yang Wang1, Bangping Qian, Baoxin Li, Guochu Qin, Zhengyang Zhou, Yong Qiu, Xizhao Sun, Bin Zhu.   

Abstract

PURPOSE: To evaluate the effectiveness of spectral CT in reducing metal artifacts caused by pedicle screws in patients with scoliosis.
MATERIALS AND METHODS: Institutional review committee approval and written informed consents from patients were obtained. 18 scoliotic patients with a total of 228 pedicle screws who underwent spectral CT imaging were included in this study. Monochromatic image sets with and without the additional metal artifacts reduction software (MARS) correction were generated with photon energy at 65keV and from 70 to 140keV with 10keV interval using the 80kVp and 140kVp projection sets. Polychromatic images corresponded to the conventional 140kVp imaging were also generated from the same scan data as a control group. Both objective evaluation (screw width and quantitative artifacts index measurements) and subjective evaluation (depiction of pedicle screws, surrounding structures and their relationship) were performed.
RESULTS: Image quality of monochromatic images in the range from 110 to 140keV (0.97±0.28) was rated superior to the conventional polychromatic images (2.53±0.54) and also better than monochromatic images with lower energy. Images of energy above 100keV also give accurate measurement of the width of screws and relatively low artifacts index. The form of screws was slightly distorted in MARS reconstruction.
CONCLUSIONS: Compared to conventional polychromatic images, monochromatic images acquired from dual-energy CT provided superior image quality with much reduced metal artifacts of pedicle screws in patients with scoliosis. Optimal energy range was found between 110 and 140keV. Crown
Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23518146     DOI: 10.1016/j.ejrad.2013.02.024

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  32 in total

1.  Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

Authors:  Min Li; Sarah Joy Castillo; Richard Castillo; Edward Castillo; Thomas Guerrero; Liang Xiao; Xiaolin Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-14       Impact factor: 2.924

2.  Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT.

Authors:  Yue Dong; Ai Jun Shi; Jian Lin Wu; Ru Xin Wang; Li Fei Sun; Ai Lian Liu; Yi Jun Liu
Journal:  Eur Spine J       Date:  2015-06-13       Impact factor: 3.134

3.  Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation.

Authors:  Yanwei Zeng; Kai Deng; Haitao Yang; Yi Tan; Jun Liu; Daoying Geng; Jun Zhang
Journal:  Eur Spine J       Date:  2019-04-30       Impact factor: 3.134

4.  Evaluation of Software-Based Metal Artifact Reduction in Intraoperative 3D Imaging of the Spine Using a Mobile Cone Beam CT.

Authors:  Maxim Privalov; Marcus Mohr; Benedict Swartman; Nils Beisemann; Holger Keil; Jochen Franke; Paul Alfred Grützner; Sven Yves Vetter
Journal:  J Digit Imaging       Date:  2020-10       Impact factor: 4.056

5.  Improved image quality in abdominal CT in patients who underwent treatment for hepatocellular carcinoma with small metal implants using a raw data-based metal artifact reduction algorithm.

Authors:  Keitaro Sofue; Takeshi Yoshikawa; Yoshiharu Ohno; Noriyuki Negi; Hiroyasu Inokawa; Naoki Sugihara; Kazuro Sugimura
Journal:  Eur Radiol       Date:  2016-12-02       Impact factor: 5.315

Review 6.  Peering through the glare: using dual-energy CT to overcome the problem of metal artefacts in bone radiology.

Authors:  Tyler M Coupal; Paul I Mallinson; Patrick McLaughlin; Savvas Nicolaou; Peter L Munk; Hugue Ouellette
Journal:  Skeletal Radiol       Date:  2014-01-17       Impact factor: 2.199

7.  An evaluation of three commercially available metal artifact reduction methods for CT imaging.

Authors:  Jessie Y Huang; James R Kerns; Jessica L Nute; Xinming Liu; Peter A Balter; Francesco C Stingo; David S Followill; Dragan Mirkovic; Rebecca M Howell; Stephen F Kry
Journal:  Phys Med Biol       Date:  2015-01-14       Impact factor: 3.609

8.  Approaches to reducing photon dose calculation errors near metal implants.

Authors:  Jessie Y Huang; David S Followill; Rebecca M Howell; Xinming Liu; Dragan Mirkovic; Francesco C Stingo; Stephen F Kry
Journal:  Med Phys       Date:  2016-09       Impact factor: 4.071

9.  Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms.

Authors:  Joel Aissa; Johannes Boos; Lino Morris Sawicki; Niklas Heinzler; Karl Krzymyk; Martin Sedlmair; Patric Kröpil; Gerald Antoch; Christoph Thomas
Journal:  Br J Radiol       Date:  2017-08-22       Impact factor: 3.039

10.  CT Metal Artifact Reduction in the Spine: Can an Iterative Reconstruction Technique Improve Visualization?

Authors:  A L Kotsenas; G J Michalak; D R DeLone; F E Diehn; K Grant; A F Halaweish; A Krauss; R Raupach; B Schmidt; C H McCollough; J G Fletcher
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-06       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.