Literature DB >> 23494090

Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study.

Corinne Dussaussoy1, Marine Peres, Virginie Jaoul, Ngai Liu, Thierry Chazot, Jean Picquet, Marc Fischler, Laurent Beydon.   

Abstract

Closed loop target-control infusion systems using a Bispectral (BIS) signal as an input (TCI Loop) can automatically maintain intravenous anesthesia in a BIS range of 40-60 %. Our purpose was to assess to what extent such a system could decrease anesthesia workload in comparison to the use of a stand alone TCI system manually adjusted to fit the same BIS range of 40-60 % (TCI Manual). Patients scheduled for elective vascular or thoracic surgery were randomized to the TCI Loop or TCI Manual method for administering propofol and remifentanil during both induction and maintenance of general anesthesia. Assessment of workload was performed by an independent observer who quoted each time the physician looked at the BIS monitor. The number of propofol and remifentanil target modifications, the percentage of time of adequate anesthesia i.e. BIS in the range 40-60 and hemodynamic data were recorded. Eighteen patients per group were enrolled. Characteristics, duration of surgery and propofol-remifentanil consumption were similar between groups. However, the percentage of time in the BIS range 40-60 % was higher in the TCI Loop versus TCI Manual groups (94 % ± 12 vs. 74 % ± 19, p < 0.001). Mean arterial pressure was lower with TCI Manual (78 ± 6 vs. 88 ± 13 mmHg, p < 0.001). The number of times the anesthesiologist watched the controller or BIS monitor (p < 0.05) and the number of manual adjustments (p < 0.001) performed in each group was lower with TCI Loop group during induction and maintenance of anesthesia. An automated controller strikingly frees the anesthesiologist from manual intervention to adjust drug delivery.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23494090     DOI: 10.1007/s10877-013-9453-6

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

1.  Closed loop control of anaesthesia: an assessment of the bispectral index as the target of control.

Authors:  A Morley; J Derrick; P Mainland; B B Lee; T G Short
Journal:  Anaesthesia       Date:  2000-10       Impact factor: 6.955

2.  Titration of propofol for anesthetic induction and maintenance guided by the bispectral index: closed-loop versus manual control: a prospective, randomized, multicenter study.

Authors:  Ngai Liu; Thierry Chazot; Antoine Genty; Alain Landais; Aymeric Restoux; Kathleen McGee; Pierre-Antoine Laloë; Bernard Trillat; Luc Barvais; Marc Fischler
Journal:  Anesthesiology       Date:  2006-04       Impact factor: 7.892

Review 3.  Closed-loop and open-loop devices for blood glucose control in normal and diabetic subjects.

Authors:  J V Santiago; A H Clemens; W L Clarke; D M Kipnis
Journal:  Diabetes       Date:  1979-01       Impact factor: 9.461

4.  Comparison of closed-loop controlled administration of propofol using Bispectral Index as the controlled variable versus "standard practice" controlled administration.

Authors:  M M Struys; T De Smet; L F Versichelen; S Van De Velde; R Van den Broecke; E P Mortier
Journal:  Anesthesiology       Date:  2001-07       Impact factor: 7.892

5.  Software safety considerations in the use of closed-loop, patient-connected control systems.

Authors:  P C Beatty
Journal:  Br J Anaesth       Date:  1993-09       Impact factor: 9.166

6.  The influence of age on propofol pharmacodynamics.

Authors:  T W Schnider; C F Minto; S L Shafer; P L Gambus; C Andresen; D B Goodale; E J Youngs
Journal:  Anesthesiology       Date:  1999-06       Impact factor: 7.892

7.  Influence of age and gender on the pharmacokinetics and pharmacodynamics of remifentanil. I. Model development.

Authors:  C F Minto; T W Schnider; T D Egan; E Youngs; H J Lemmens; P L Gambus; V Billard; J F Hoke; K H Moore; D J Hermann; K T Muir; J W Mandema; S L Shafer
Journal:  Anesthesiology       Date:  1997-01       Impact factor: 7.892

8.  Feasibility of closed-loop titration of propofol guided by the Bispectral Index for general anaesthesia induction: a prospective randomized study.

Authors:  N Liu; T Chazot; B Trillat; R Pirracchio; J-D Law-Koune; L Barvais; M Fischler
Journal:  Eur J Anaesthesiol       Date:  2006-06       Impact factor: 4.330

9.  Closed-loop controlled administration of propofol using bispectral analysis.

Authors:  E Mortier; M Struys; T De Smet; L Versichelen; G Rolly
Journal:  Anaesthesia       Date:  1998-08       Impact factor: 6.955

Review 10.  A model for technology assessment as applied to closed loop infusion systems. Technology Assessment Task Force of the Society of Critical Care Medicine.

Authors:  M Jastremski; C Jastremski; M Shepherd; V Friedman; D Porembka; R Smith; E Gonzales; D Swedlow; H Belzberg; R Crass
Journal:  Crit Care Med       Date:  1995-10       Impact factor: 7.598

View more
  7 in total

1.  Closed-loop systems and automation in the era of patients safety and perioperative medicine.

Authors:  Maxime Cannesson; Joseph Rinehart
Journal:  J Clin Monit Comput       Date:  2014-02       Impact factor: 2.502

2.  A novel system for automated propofol sedation: hybrid sedation system (HSS).

Authors:  Cedrick Zaouter; Riccardo Taddei; Mohamad Wehbe; Erik Arbeid; Shantale Cyr; Francesco Giunta; Thomas M Hemmerling
Journal:  J Clin Monit Comput       Date:  2016-03-12       Impact factor: 2.502

Review 3.  [Perioperative risk and mortality after major surgery].

Authors:  O Boehm; M K A Pfeiffer; G Baumgarten; A Hoeft
Journal:  Anaesthesist       Date:  2015-11       Impact factor: 1.041

4.  Closed-loop assisted versus manual goal-directed fluid therapy during high-risk abdominal surgery: a case-control study with propensity matching.

Authors:  Joseph Rinehart; Marc Lilot; Christine Lee; Alexandre Joosten; Trish Huynh; Cecilia Canales; David Imagawa; Aram Demirjian; Maxime Cannesson
Journal:  Crit Care       Date:  2015-03-19       Impact factor: 9.097

5.  Closed-loop control better than open-loop control of profofol TCI guided by BIS: a randomized, controlled, multicenter clinical trial to evaluate the CONCERT-CL closed-loop system.

Authors:  Yu Liu; Min Li; Dong Yang; Xuena Zhang; Anshi Wu; Shanglong Yao; Zhanggang Xue; Yun Yue
Journal:  PLoS One       Date:  2015-04-17       Impact factor: 3.240

Review 6.  Pharmacokinetic-pharmacodynamic relationship of anesthetic drugs: from modeling to clinical use.

Authors:  Valerie Billard
Journal:  F1000Res       Date:  2015-11-18

7.  Practical Use of Regularization in Individualizing a Mathematical Model of Cardiovascular Hemodynamics Using Scarce Data.

Authors:  Ali Tivay; Xin Jin; Alex Kai-Yuan Lo; Christopher G Scully; Jin-Oh Hahn
Journal:  Front Physiol       Date:  2020-05-26       Impact factor: 4.566

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.