Literature DB >> 11012489

Closed loop control of anaesthesia: an assessment of the bispectral index as the target of control.

A Morley1, J Derrick, P Mainland, B B Lee, T G Short.   

Abstract

We investigated the performance of a closed-loop system for administration of general anaesthesia, using the bispectral index as a target for control. One hundred patients undergoing gynaecological or general surgery were studied. In 60 patients, anaesthesia was maintained by intravenous infusion of a propofol/alfentanil mixture. In 40, an isoflurane/nitrous oxide based technique was used. For each technique, patients were randomly allocated to receive either closed-loop or manually controlled administration of the relevant agents (propofol/alfentanil or isoflurane), with an intra-operative target bispectral index of 50 in all cases. Closed-loop and manually controlled administration of anaesthesia resulted in similar intra-operative conditions and initial recovery characteristics. During maintenance of anaesthesia, cardiovascular and electro-encephalographic variables did not differ between closed-loop and manual control groups and deviation of bispectral index from the target value was similar. Intra-operative concentrations of propofol, alfentanil and isoflurane were within normal clinical ranges. Episodes of light anaesthesia were more common in the closed-loop group for patients receiving propofol/alfentanil anaesthesia and in the manual group for patients receiving isoflurane/nitrous oxide anaesthesia. Convenience aside, the closed-loop system showed no clinical advantage over conventional, manually adjusted techniques of anaesthetic administration.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11012489     DOI: 10.1046/j.1365-2044.2000.01527.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  12 in total

1.  Lessons learned from closed loops in engineering: towards a multivariable approach regulating depth of anaesthesia.

Authors:  Clara M Ionescu; Ioana Nascu; Robin De Keyser
Journal:  J Clin Monit Comput       Date:  2013-11-23       Impact factor: 2.502

2.  An Adaptive Monitoring Scheme for Automatic Control of Anaesthesia in dynamic surgical environments based on Bispectral Index and Blood Pressure.

Authors:  Yu-Ning Yu; Faiyaz Doctor; Shou-Zen Fan; Jiann-Shing Shieh
Journal:  J Med Syst       Date:  2018-04-13       Impact factor: 4.460

Review 3.  Neuroelectronics and Biooptics: Closed-Loop Technologies in Neurological Disorders.

Authors:  Esther Krook-Magnuson; Jennifer N Gelinas; Ivan Soltesz; György Buzsáki
Journal:  JAMA Neurol       Date:  2015-07       Impact factor: 18.302

4.  A closed-loop anesthetic delivery system for real-time control of burst suppression.

Authors:  Max Y Liberman; Shinung Ching; Jessica Chemali; Emery N Brown
Journal:  J Neural Eng       Date:  2013-06-07       Impact factor: 5.379

5.  Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study.

Authors:  Corinne Dussaussoy; Marine Peres; Virginie Jaoul; Ngai Liu; Thierry Chazot; Jean Picquet; Marc Fischler; Laurent Beydon
Journal:  J Clin Monit Comput       Date:  2013-03-15       Impact factor: 2.502

6.  [Propofol administration systems. Handling, hemodynamics and propofol consumption].

Authors:  J G Triem; K D Röhm; J Boldt; S N Piper
Journal:  Anaesthesist       Date:  2009-03       Impact factor: 1.041

7.  Real-time closed-loop control in a rodent model of medically induced coma using burst suppression.

Authors:  ShiNung Ching; Max Y Liberman; Jessica J Chemali; M Brandon Westover; Jonathan D Kenny; Ken Solt; Patrick L Purdon; Emery N Brown
Journal:  Anesthesiology       Date:  2013-10       Impact factor: 7.892

8.  A technical description of a novel pharmacological anesthesia robot.

Authors:  Mohamad Wehbe; Erik Arbeid; Shantale Cyr; Pierre A Mathieu; Riccardo Taddei; Joshua Morse; Thomas M Hemmerling
Journal:  J Clin Monit Comput       Date:  2013-06-15       Impact factor: 2.502

9.  A brain-machine interface for control of medically-induced coma.

Authors:  Maryam M Shanechi; Jessica J Chemali; Max Liberman; Ken Solt; Emery N Brown
Journal:  PLoS Comput Biol       Date:  2013-10-31       Impact factor: 4.475

10.  A Comparison of Multiscale Permutation Entropy Measures in On-Line Depth of Anesthesia Monitoring.

Authors:  Cui Su; Zhenhu Liang; Xiaoli Li; Duan Li; Yongwang Li; Mauro Ursino
Journal:  PLoS One       Date:  2016-10-10       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.