Xu Li1, Feng Zhang1, Wenzhi Zhang2, Xifu Shang1, Jintao Han3, Pengfei Liu1. 1. Department of Orthopedics, Spine Center, Anhui Medical University Affiliated Provincial Hospital, No. 17, Lujiang Road, Hefei, 230041, China. 2. Department of Orthopedics, Spine Center, Anhui Medical University Affiliated Provincial Hospital, No. 17, Lujiang Road, Hefei, 230041, China. zwzspine@hotmail.com. 3. Peking University Third Hospital Intervention and Vascular Surgery, Beijing, 100083, China.
Abstract
STUDY DESIGN: Technique note. OBJECTIVES: To report a new method for precisely controlling the depth of percutaneous pedicle screws (PPS)-without radiation exposure to surgeons and less fluoroscopy exposure to patients than with conventional methods. PPS is widely used in minimal invasive spine surgery; the advantages include reduced muscle damage, pain, and hospital stays. However, placement of PPS demands repeated checking with fluoroscopy. Thus, radiation exposure is considerable for both surgeons and patients. METHODS: The PPS depth was determined by counting rotations of the screws. The distance between screw threads can be measured for particular screws; thus, full rotations of the PPS results in the screw advancing in the pedicle the distance between screw threads. To fully insert screws into the pedicle, the number of full rotations is equal to the number of threads in the PPS. RESULTS: We applied this technique in 58 patients with thoracolumbar fracture. The position and depth of the screws was checked during the operation with the C-arm and after operation by anteroposterior X-ray film or computed tomography. No additional procedures were required to correct the screws; we observed no neurological deficits or malpositioning of the screws. In the screw placement procedure, the radiation exposure for surgeons is zero, and the patient is well protected from extensive radiation exposure. CONCLUSIONS: This method of counting rotation of screws is a safe way to precisely determine the depth of PPS in the placement procedure. LEVEL OF EVIDENCE: IV.
STUDY DESIGN: Technique note. OBJECTIVES: To report a new method for precisely controlling the depth of percutaneous pedicle screws (PPS)-without radiation exposure to surgeons and less fluoroscopy exposure to patients than with conventional methods. PPS is widely used in minimal invasive spine surgery; the advantages include reduced muscle damage, pain, and hospital stays. However, placement of PPS demands repeated checking with fluoroscopy. Thus, radiation exposure is considerable for both surgeons and patients. METHODS: The PPS depth was determined by counting rotations of the screws. The distance between screw threads can be measured for particular screws; thus, full rotations of the PPS results in the screw advancing in the pedicle the distance between screw threads. To fully insert screws into the pedicle, the number of full rotations is equal to the number of threads in the PPS. RESULTS: We applied this technique in 58 patients with thoracolumbar fracture. The position and depth of the screws was checked during the operation with the C-arm and after operation by anteroposterior X-ray film or computed tomography. No additional procedures were required to correct the screws; we observed no neurological deficits or malpositioning of the screws. In the screw placement procedure, the radiation exposure for surgeons is zero, and the patient is well protected from extensive radiation exposure. CONCLUSIONS: This method of counting rotation of screws is a safe way to precisely determine the depth of PPS in the placement procedure. LEVEL OF EVIDENCE: IV.
Entities:
Keywords:
Depth of the screws; Percutaneous pedicle screws (PPS); Radiation exposure; Radiation protection
Authors: D Greg Anderson; Amirali Sayadipour; Kevin Shelby; Todd J Albert; Alexander R Vaccaro; Michael S Weinstein Journal: Eur Spine J Date: 2011-04-13 Impact factor: 3.134
Authors: N Bronsard; T Boli; M Challali; R de Dompsure; N Amoretti; B Padovani; G Bruneton; A Fuchs; F de Peretti Journal: Orthop Traumatol Surg Res Date: 2013-03-01 Impact factor: 2.256
Authors: Kostas Perisinakis; John Damilakis; Nicholas Theocharopoulos; George Papadokostakis; Alexandros Hadjipavlou; Nicholas Gourtsoyiannis Journal: Radiology Date: 2004-07-23 Impact factor: 11.105