Literature DB >> 23452997

First experience with monochromatic coronary computed tomography angiography from a 64-slice CT scanner with Gemstone Spectral Imaging (GSI).

Tobias A Fuchs1, Julia Stehli, Michael Fiechter, Svetlana Dougoud, Cathérine Gebhard, Jelena R Ghadri, Lars Husmann, Oliver Gaemperli, Philipp A Kaufmann.   

Abstract

BACKGROUND: New technology combining dual-energy CT with the latest gemstone detectors for spectral imaging (GSI) can be used to synthesize monochromatic images that mimic images as if different monochromatic x-ray sources were used.
OBJECTIVE: The aim of the study was to evaluate the optimal combination of monochromatic image energy and adaptive statistical iterative reconstruction (ASiR) for monochromatic reconstruction of coronary CT angiography (CTA) images with the use of GSI.
METHODS: Twenty consecutive patients underwent coronary CTA on a GSI capable 64-slice CT scanner (Discovery CT 750 High Definition, GE Healthcare). In 7 sets of monochromatic images (60, 65, 70, 75, 80, 90, and 110 keV; each with increasing contributions of ASiR, ie, 0%, 20%, 40%, 60%, and 80%; n = 35 reconstructions per patient), signal-to-noise (aortic root) and contrast-to-noise (left main artery) ratios were assessed. Signal-to-noise ratio, contrast-to-noise ratio, and image quality (graded on a 5-point Likert scale) were assessed in all above monochromatic reconstructions and compared with the respective standard (conventional polychromatic) image.
RESULTS: Compared with conventional polychromatic images, reconstructions with 60 keV and 80% ASiR showed the highest improvement in contrast-to-noise (144%; P < 0.001) and signal-to-noise ratio (173%; P < 0.001). Image quality reached a plateau at 65-75 keV with 40%-60% ASiR blending, yielding a maximal image quality score improvement of 50% compared with conventional imaging (P < 0.001).
CONCLUSION: In coronary CTA with low radiation technique (mean radiation dose, 1.8 ± 0.7 mSv), GSI with monochromatic reconstructions (65-75 keV) and ASiR (40%-60%) offers significant noise reduction and image quality improvement.
Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23452997     DOI: 10.1016/j.jcct.2013.01.004

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  20 in total

1.  CT angiography of the kidney using routine CT and the latest Gemstone Spectral Imaging combination of different noise indexes: image quality and radiation dose.

Authors:  Yongxia Zhao; Yanmin Wu; Ziwei Zuo; Shujie Cheng
Journal:  Radiol Med       Date:  2017-02-15       Impact factor: 3.469

2.  Automatic Valve Plane Localization in Myocardial Perfusion SPECT/CT by Machine Learning: Anatomic and Clinical Validation.

Authors:  Julian Betancur; Mathieu Rubeaux; Tobias A Fuchs; Yuka Otaki; Yoav Arnson; Leandro Slipczuk; Dominik C Benz; Guido Germano; Damini Dey; Chih-Jen Lin; Daniel S Berman; Philipp A Kaufmann; Piotr J Slomka
Journal:  J Nucl Med       Date:  2016-11-03       Impact factor: 10.057

3.  SPECT vs CT: CT is not the first line test for the diagnosis and prognosis of stable coronary artery disease.

Authors:  Zachary J Trzaska; Mylan C Cohen
Journal:  J Nucl Cardiol       Date:  2013-06       Impact factor: 5.952

4.  A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography.

Authors:  Stefanie Mangold; Carlo N De Cecco; U Joseph Schoepf; Ricardo T Yamada; Akos Varga-Szemes; Andrew C Stubenrauch; Damiano Caruso; Stephen R Fuller; Thomas J Vogl; Konstantin Nikolaou; Thomas M Todoran; Julian L Wichmann
Journal:  Eur Radiol       Date:  2016-03-09       Impact factor: 5.315

5.  Analysis of coronary arterial calcification components with coronary CT angiography using single-source dual-energy CT with fast tube voltage switching.

Authors:  Kazuhiro Matsui; Haruhiko Machida; Tetsuya Mitsuhashi; Hisako Omori; Takashi Nakaoka; Hiroshi Sakura; Eiko Ueno
Journal:  Int J Cardiovasc Imaging       Date:  2014-11-19       Impact factor: 2.357

6.  Subtraction CT angiography in head and neck with low radiation and contrast dose dual-energy spectral CT using rapid kV-switching technique.

Authors:  Guangming Ma; Yong Yu; Haifeng Duan; Yuequn Dou; Yongjun Jia; Xirong Zhang; Chuangbo Yang; Xiaoxia Chen; Dong Han; Changyi Guo; Taiping He
Journal:  Br J Radiol       Date:  2018-03-07       Impact factor: 3.039

7.  Improved Calcium Scoring at Dual-Energy Computed Tomography Angiography Using a High-Z Contrast Element and Novel Material Separation Technique.

Authors:  Jack W Lambert; Yuxin Sun; Karen G Ordovas; Robert G Gould; Sizhe Wang; Benjamin M Yeh
Journal:  J Comput Assist Tomogr       Date:  2018 May/Jun       Impact factor: 1.826

8.  Unstable plaques hide in heavily calcified coronary arteries.

Authors:  Wei-Hua Yin; Hong-Yue Wang; Yan Zhang; Bin Lu; Yang Sun; Xiang-Nan Li; Zhong-Fei Lu; Yun-Qiang An; Zhi-Hui Hou; Jie Zhang; Xin-Shuang Ren; U Joseph Schoepf
Journal:  Quant Imaging Med Surg       Date:  2022-05

9.  Image quality improvements using adaptive statistical iterative reconstruction for evaluating chronic myocardial infarction using iodine density images with spectral CT.

Authors:  Junichi Kishimoto; Yasutoshi Ohta; Shinichiro Kitao; Tomomi Watanabe; Toshihide Ogawa
Journal:  Int J Cardiovasc Imaging       Date:  2017-10-19       Impact factor: 2.357

10.  Dual energy CT angiography in peripheral arterial stents: optimal scanning protocols with regard to image quality and radiation dose.

Authors:  Abdulrahman Almutairi; Zakariya Al Safran; Saif A AlZaabi; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2017-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.