Literature DB >> 27811121

Automatic Valve Plane Localization in Myocardial Perfusion SPECT/CT by Machine Learning: Anatomic and Clinical Validation.

Julian Betancur1, Mathieu Rubeaux1, Tobias A Fuchs2, Yuka Otaki1, Yoav Arnson1, Leandro Slipczuk1, Dominik C Benz2, Guido Germano1, Damini Dey1, Chih-Jen Lin3, Daniel S Berman1, Philipp A Kaufmann2, Piotr J Slomka4.   

Abstract

Precise definition of the mitral valve plane (VP) during segmentation of the left ventricle for SPECT myocardial perfusion imaging (MPI) quantification often requires manual adjustment, which affects the quantification of perfusion. We developed a machine learning approach using support vector machines (SVM) for automatic VP placement.
Methods: A total of 392 consecutive patients undergoing 99mTc-tetrofosmin stress (5 min; mean ± SD, 350 ± 54 MBq) and rest (5 min; 1,024 ± 153 MBq) fast SPECT MPI attenuation corrected (AC) by CT and same-day coronary CT angiography were studied; included in the 392 patients were 48 patients who underwent invasive coronary angiography and had no known coronary artery disease. The left ventricle was segmented with standard clinical software (quantitative perfusion SPECT) by 2 experts, adjusting the VP if needed. Two-class SVM models were computed from the expert placements with 10-fold cross validation to separate the patients used for training and those used for validation. SVM probability estimates were used to compute the best VP position. Automatic VP localizations on AC and non-AC images were compared with expert placement on coronary CT angiography. Stress and rest total perfusion deficits and detection of per-vessel obstructive stenosis by invasive coronary angiography were also compared.
Results: Bland-Altman 95% confidence intervals (CIs) for VP localization by SVM and experts for AC stress images (bias, 1; 95% CI, -5 to 7 mm) and AC rest images (bias, 1; 95% CI, -7 to 10 mm) were narrower than interexpert 95% CIs for AC stress images (bias, 0; 95% CI, -8 to 8 mm) and AC rest images (bias, 0; 95% CI, -10 to 10 mm) (P < 0.01). Bland-Altman 95% CIs for VP localization by SVM and experts for non-AC stress images (bias, 1; 95% CI, -4 to 6 mm) and non-AC rest images (bias, 2; 95% CI, -7 to 10 mm) were similar to interexpert 95% CIs for non-AC stress images (bias, 0; 95% CI, -6 to 5 mm) and non-AC rest images (bias, -1; 95% CI, -9 to 7 mm) (P was not significant [NS]). For regional detection of obstructive stenosis, ischemic total perfusion deficit areas under the receiver operating characteristic curve for the 2 experts (AUC, 0.79 [95% CI, 0.7-0.87]; AUC, 0.81 [95% CI, 0.73-0.89]) and the SVM (0.82 [0.74-0.9]) for AC data were the same (P = NS) and were higher than those for the unadjusted VP (0.63 [0.53-0.73]) (P < 0.01). Similarly, for non-AC data, areas under the receiver operating characteristic curve for the experts (AUC, 0.77 [95% CI, 0.69-0.89]; AUC, 0.8 [95% CI, 0.72-0.88]) and the SVM (0.79 [0.71-0.87]) were the same (P = NS) and were higher than those for the unadjusted VP (0.65 [0.56-0.75]) (P < 0.01).
Conclusion: Machine learning with SVM allows automatic and accurate VP localization, decreasing user dependence in SPECT MPI quantification.
© 2017 by the Society of Nuclear Medicine and Molecular Imaging.

Entities:  

Keywords:  SPECT quantification; coronary CT angiography; machine learning; myocardial perfusion imaging; support vector classification

Mesh:

Year:  2016        PMID: 27811121      PMCID: PMC5450369          DOI: 10.2967/jnumed.116.179911

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  23 in total

Review 1.  Transient ischemic dilation: a powerful diagnostic and prognostic finding of stress myocardial perfusion imaging.

Authors:  Michael G McLaughlin; Peter G Danias
Journal:  J Nucl Cardiol       Date:  2002 Nov-Dec       Impact factor: 5.952

2.  Automated quantification of myocardial perfusion SPECT using simplified normal limits.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Cigdem Akincioglu; Aiden Abidov; John D Friedman; Sean W Hayes; Guido Germano
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

3.  Prediction error estimation: a comparison of resampling methods.

Authors:  Annette M Molinaro; Richard Simon; Ruth M Pfeiffer
Journal:  Bioinformatics       Date:  2005-05-19       Impact factor: 6.937

4.  Quantification of nuclear cardiac images: the Yale approach.

Authors:  Yi-Hwa Liu
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

5.  The increasing role of quantification in clinical nuclear cardiology: the Emory approach.

Authors:  Ernest V Garcia; Tracy L Faber; C David Cooke; Russell D Folks; Ji Chen; Cesar Santana
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography.

Authors:  Michael Fiechter; Jelena R Ghadri; Silke M Kuest; Aju P Pazhenkottil; Mathias Wolfrum; Rene N Nkoulou; Robert Goetti; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-07-15       Impact factor: 9.236

8.  Prediction of revascularization after myocardial perfusion SPECT by machine learning in a large population.

Authors:  Reza Arsanjani; Damini Dey; Tigran Khachatryan; Aryeh Shalev; Sean W Hayes; Mathews Fish; Rine Nakanishi; Guido Germano; Daniel S Berman; Piotr Slomka
Journal:  J Nucl Cardiol       Date:  2014-12-06       Impact factor: 5.952

9.  High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging.

Authors:  Tali Sharir; Simona Ben-Haim; Konstantine Merzon; Vitali Prochorov; Dalia Dickman; Shlomo Ben-Haim; Daniel S Berman
Journal:  JACC Cardiovasc Imaging       Date:  2008-03

10.  Automated quality control for segmentation of myocardial perfusion SPECT.

Authors:  Yuan Xu; Paul Kavanagh; Mathews Fish; James Gerlach; Amit Ramesh; Mark Lemley; Sean Hayes; Daniel S Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Med       Date:  2009-08-18       Impact factor: 10.057

View more
  15 in total

1.  Deep Learning Analysis of Upright-Supine High-Efficiency SPECT Myocardial Perfusion Imaging for Prediction of Obstructive Coronary Artery Disease: A Multicenter Study.

Authors:  Julian Betancur; Lien-Hsin Hu; Frederic Commandeur; Tali Sharir; Andrew J Einstein; Mathews B Fish; Terrence D Ruddy; Philipp A Kaufmann; Albert J Sinusas; Edward J Miller; Timothy M Bateman; Sharmila Dorbala; Marcelo Di Carli; Guido Germano; Yuka Otaki; Joanna X Liang; Balaji K Tamarappoo; Damini Dey; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Med       Date:  2018-09-27       Impact factor: 10.057

2.  Novel SPECT Technologies and Approaches in Cardiac Imaging.

Authors:  Piotr Slomka; Guang-Uei Hung; Guido Germano; Daniel S Berman
Journal:  Cardiovasc Innov Appl       Date:  2016-12-01

3.  Machine learning for nuclear cardiology: The way forward.

Authors:  Sirish Shrestha; Partho P Sengupta
Journal:  J Nucl Cardiol       Date:  2018-04-20       Impact factor: 5.952

4.  Machine learning predicts per-vessel early coronary revascularization after fast myocardial perfusion SPECT: results from multicentre REFINE SPECT registry.

Authors:  Lien-Hsin Hu; Julian Betancur; Tali Sharir; Andrew J Einstein; Sabahat Bokhari; Mathews B Fish; Terrence D Ruddy; Philipp A Kaufmann; Albert J Sinusas; Edward J Miller; Timothy M Bateman; Sharmila Dorbala; Marcelo Di Carli; Guido Germano; Frederic Commandeur; Joanna X Liang; Yuka Otaki; Balaji K Tamarappoo; Damini Dey; Daniel S Berman; Piotr J Slomka
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2020-05-01       Impact factor: 6.875

Review 5.  Application of artificial intelligence in nuclear medicine and molecular imaging: a review of current status and future perspectives for clinical translation.

Authors:  Dimitris Visvikis; Philippe Lambin; Kim Beuschau Mauridsen; Roland Hustinx; Michael Lassmann; Christoph Rischpler; Kuangyu Shi; Jan Pruim
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-07-09       Impact factor: 9.236

6.  Deep Learning for Prediction of Obstructive Disease From Fast Myocardial Perfusion SPECT: A Multicenter Study.

Authors:  Julian Betancur; Frederic Commandeur; Mahsaw Motlagh; Tali Sharir; Andrew J Einstein; Sabahat Bokhari; Mathews B Fish; Terrence D Ruddy; Philipp Kaufmann; Albert J Sinusas; Edward J Miller; Timothy M Bateman; Sharmila Dorbala; Marcelo Di Carli; Guido Germano; Yuka Otaki; Balaji K Tamarappoo; Damini Dey; Daniel S Berman; Piotr J Slomka
Journal:  JACC Cardiovasc Imaging       Date:  2018-03-14

7.  Prognostic Value of Combined Clinical and Myocardial Perfusion Imaging Data Using Machine Learning.

Authors:  Julian Betancur; Yuka Otaki; Manish Motwani; Mathews B Fish; Mark Lemley; Damini Dey; Heidi Gransar; Balaji Tamarappoo; Guido Germano; Tali Sharir; Daniel S Berman; Piotr J Slomka
Journal:  JACC Cardiovasc Imaging       Date:  2017-10-18

Review 8.  Quantitative clinical nuclear cardiology, part 2: Evolving/emerging applications.

Authors:  Piotr J Slomka; Jonathan B Moody; Robert J H Miller; Jennifer M Renaud; Edward P Ficaro; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2020-10-16       Impact factor: 5.952

9.  New Trends in Quantitative Nuclear Cardiology Methods.

Authors:  Javier Gomez; Rami Doukky; Guido Germano; Piotr Slomka
Journal:  Curr Cardiovasc Imaging Rep       Date:  2018-01-19

10.  Machine Learning Adds to Clinical and CAC Assessments in Predicting 10-Year CHD and CVD Deaths.

Authors:  Rine Nakanishi; Piotr J Slomka; Richard Rios; Julian Betancur; Michael J Blaha; Khurram Nasir; Michael D Miedema; John A Rumberger; Heidi Gransar; Leslee J Shaw; Alan Rozanski; Matthew J Budoff; Daniel S Berman
Journal:  JACC Cardiovasc Imaging       Date:  2020-10-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.