Literature DB >> 23452221

Biocompatibility assessment of a long-term wearable artificial pump-lung in sheep.

Kang Zhou1, Shuqiong Niu, Giacomo Bianchi, Xufeng Wei, Narayana Garimella, Bartley P Griffith, Zhongjun J Wu.   

Abstract

The purpose of this study was to assess the biocompatibility of a newly developed long-term wearable artificial pump-lung (APL) in a clinically relevant ovine animal model. The wearable APL device was implanted in five sheep through left thoracotomy. The device was connected between the right atrium and pulmonary artery and evaluated for 30 days. Three sheep were used as the sham control. Platelet activation was assessed by measuring platelet surface P-selectin (CD62P) expression with flow cytometry and plasma soluble P-selectin with an enzyme-linked immunosorbent assay. Thrombotic deposition on the device components and hollow fiber membranes were analyzed with digital imaging and scanning electron microscopy. Surface P-selectin of the APL and sham groups changed significantly over the study period, but without significant differences between the two groups. Soluble P-selectin for the two groups peaked in the first 24 h after the surgery. Soluble P-selectin of the APL group remained slightly elevated over the study period compared to the presurgical baseline value and was slightly higher compared to that of the sham group. Plasma free hemoglobin remained in the normal ranges in all the animals. In spite of the surgery-related alteration in laboratory tests and elevation of platelet activation status, the APL devices in all the animals functioned normally (oxygen transfer and blood pumping) during the 30-day study period. The device flow path and membrane surface were free of gross thrombus. Electron microscopy images showed only scattered thrombi on the fibers (membrane surface and weft). In summary, the APL exhibited excellent biocompatibility. Two forms of platelet activation, surgery-related and device-induced, in the animals implanted with the wearable APL were observed. The limited device-induced platelet activation did not cause gross thrombosis and impair the long-term device performance.
© 2013, Copyright the Authors. Artificial Organs © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

Entities:  

Keywords:  Artificial lungs; Biocompatibility; Extracorporeal membrane oxygenation; Integrated pump-oxygenators; Platelet activation

Mesh:

Year:  2013        PMID: 23452221      PMCID: PMC3675162          DOI: 10.1111/aor.12049

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  32 in total

1.  Thirty-day in-parallel artificial lung testing in sheep.

Authors:  Hitoshi Sato; Candice M Hall; Nathan G Lafayette; Joshua R Pohlmann; Niru Padiyar; John M Toomasian; Jonathan W Haft; Keith E Cook
Journal:  Ann Thorac Surg       Date:  2007-10       Impact factor: 4.330

2.  Pumpless extracorporeal lung assist: a 10-year institutional experience.

Authors:  Bernhard Flörchinger; Alois Philipp; Alexander Klose; Michael Hilker; Reinhard Kobuch; Leopold Rupprecht; Andreas Keyser; Thomas Pühler; Stephan Hirt; Karsten Wiebe; Thomas Müller; Julia Langgartner; Karla Lehle; Christof Schmid
Journal:  Ann Thorac Surg       Date:  2008-08       Impact factor: 4.330

Review 3.  Methods for the measurement of platelet function.

Authors:  Alan D Michelson
Journal:  Am J Cardiol       Date:  2009-02-02       Impact factor: 2.778

4.  The role of the extracorporeal circuit in the trapping and degranulation of platelets.

Authors:  Mareille Gritters-van den Oever; Marianne Schoorl; Margreet Schoorl; Piet C M Bartels; Muriel P C Grooteman; Menso J Nubé
Journal:  Blood Purif       Date:  2009-08-14       Impact factor: 2.614

5.  Blood biocompatibility assessment of an intravenous gas exchange device.

Authors:  Trevor A Snyder; Heide J Eash; Kenneth N Litwak; Brian J Frankowski; Brack G Hattler; William J Federspiel; William R Wagner
Journal:  Artif Organs       Date:  2006-09       Impact factor: 3.094

6.  Functional and biocompatibility performances of an integrated Maglev pump-oxygenator.

Authors:  Tao Zhang; Guangming Cheng; Andrew Koert; Juntao Zhang; Barry Gellman; G Kwame Yankey; Aditee Satpute; Kurt A Dasse; Richard J Gilbert; Bartley P Griffith; Zhongjun J Wu
Journal:  Artif Organs       Date:  2009-01       Impact factor: 3.094

Review 7.  Blood coagulation: hemostasis and thrombin regulation.

Authors:  Kenichi A Tanaka; Nigel S Key; Jerrold H Levy
Journal:  Anesth Analg       Date:  2009-05       Impact factor: 5.108

8.  Assessing aspirin-induced attenuation of platelet reactivity by flow cytometry.

Authors:  Wolfgang Hübl; Afshin Assadian; Jaqueline Lax; Ursula Meixner; I-Fei Fang; Georg Hagmüller; Simon Panzer; Peter M Bayer
Journal:  Thromb Res       Date:  2007-04-30       Impact factor: 3.944

Review 9.  Review of the biology of bleeding and clotting in the surgical patient.

Authors:  Hardean E Achneck; Bantayehu Sileshi; Jeffrey H Lawson
Journal:  Vascular       Date:  2008 Mar-Apr       Impact factor: 1.285

10.  Efficiency in extracorporeal membrane oxygenation-cellular deposits on polymethylpentene membranes increase resistance to blood flow and reduce gas exchange capacity.

Authors:  Karla Lehle; Alois Philipp; Otto Gleich; Andreas Holzamer; Thomas Müller; Thomas Bein; Christof Schmid
Journal:  ASAIO J       Date:  2008 Nov-Dec       Impact factor: 2.872

View more
  3 in total

1.  A Model of Pediatric End-Stage Lung Failure in Small Lambs <20 kg.

Authors:  Benjamin D Carr; Clinton J Poling; Pavel Hala; Matias Caceres Quinones; Aaron R Prater; Jennifer S McLeod; Robert H Bartlett; Alvaro Rojas-Pena; Ronald B Hirschl
Journal:  ASAIO J       Date:  2020-05       Impact factor: 3.826

2.  Month-long Respiratory Support by a Wearable Pumping Artificial Lung in an Ovine Model.

Authors:  Ryan A Orizondo; Katelin S Omecinski; Alexandra G May; Vishaal Dhamotharan; Brian J Frankowski; Greg W Burgreen; Sang-Ho Ye; Ergin Kocyildirim; Pablo G Sanchez; Jonathan D'Cunha; William R Wagner; William J Federspiel
Journal:  Transplantation       Date:  2021-05-01       Impact factor: 5.385

Review 3.  Bioengineering Progress in Lung Assist Devices.

Authors:  Ahad Syed; Sarah Kerdi; Adnan Qamar
Journal:  Bioengineering (Basel)       Date:  2021-06-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.