Literature DB >> 19033775

Efficiency in extracorporeal membrane oxygenation-cellular deposits on polymethylpentene membranes increase resistance to blood flow and reduce gas exchange capacity.

Karla Lehle1, Alois Philipp, Otto Gleich, Andreas Holzamer, Thomas Müller, Thomas Bein, Christof Schmid.   

Abstract

Bioline-coated polymethylpentene (PMP) membrane oxygenators (MO) are used for extracorporeal membrane oxygenation (ECMO) to improve gas exchange in patients with severe acute respiratory distress syndrome (ARDS). However, in some patients, long-term durability is limited due to fibrous and cellular accumulations on the gas exchange surface which can increase resistance to blood flow and diffusion path. These surface deposits of PMP MO after removal were studied with scanning electron and fluorescence microscopy techniques. Three of 31 patients supported by a PMP MO in an ECMO setting required a replacement of the oxygenator after a mean support interval of 11 +/- 7 days due to an increase in flow resistance and an impairment of the gas exchange capacity. The membrane surface of the MO was covered with a fibrous network with imbedded platelets and red blood cells. A membranous structure composed of single cells and clusters of cells covered large areas of the PMP fibers. We assume that these cellular deposits lower the efficacy of ECMO. The identification of these cells could be a key for future therapeutic interventions and improvements in the development of MO.

Entities:  

Mesh:

Year:  2008        PMID: 19033775     DOI: 10.1097/MAT.0b013e318186a807

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  24 in total

1.  How to Manage Thrombocytopenia with ECLS: A Proposal of Clinical Reasoning Tools.

Authors:  Adrien Koeltz; Nicolas Gendron; Nadine Ajzenberg; Dan Longrois
Journal:  J Extra Corpor Technol       Date:  2018-12

2.  Performance and Safety of an Integrated Portable Extracorporeal Life Support System for Adults.

Authors:  Cory M Alwardt; Donald S Wilson; Michelle L Alore; Louis A Lanza; Patrick A Devaleria; Octavio E Pajaro
Journal:  J Extra Corpor Technol       Date:  2015-03

3.  Thirty-day in-vivo performance of a wearable artificial pump-lung for ambulatory respiratory support.

Authors:  Zhongjun J Wu; Tao Zhang; Giacomo Bianchi; Xufeng Wei; Ho-Sung Son; Kang Zhou; Pablo G Sanchez; Jose Garcia; Bartley P Griffith
Journal:  Ann Thorac Surg       Date:  2011-11-25       Impact factor: 4.330

4.  Extracorporeal oxygenation and COVID-19 epidemic: is the membrane fail-safe to cross contamination?

Authors:  Enrico Squiccimarro; Ruggiero Rociola; Renard Gerhardus Haumann; Salvatore Grasso; Roberto Lorusso; Domenico Paparella
Journal:  ASAIO J       Date:  2020-05-07       Impact factor: 2.872

5.  Hollow Fiber Oxygenator Composition Has a Significant Impact on Failure Rates in Neonates on Extracorporeal Membrane Oxygenation: A Retrospective Analysis.

Authors:  John M Daniel; Philip A Bernard; Sean C Skinner; Prasad Bhandary; Ana Ruzic; Matthew K Bacon; Hubert O Ballard
Journal:  J Pediatr Intensive Care       Date:  2017-03-07

Review 6.  Oxygenator performance and artificial-native lung interaction.

Authors:  Francesco Epis; Mirko Belliato
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

7.  Effects on membrane lung gas exchange of an intermittent high gas flow recruitment maneuver: preliminary data in veno-venous ECMO patients.

Authors:  Luigi Castagna; Alberto Zanella; Vittorio Scaravilli; Federico Magni; Salua Abd El Aziz El Sayed Deab; Michele Introna; Francesco Mojoli; Giacomo Grasselli; Antonio Pesenti; Nicolò Patroniti
Journal:  J Artif Organs       Date:  2015-03-26       Impact factor: 1.731

8.  Biocompatibility assessment of a long-term wearable artificial pump-lung in sheep.

Authors:  Kang Zhou; Shuqiong Niu; Giacomo Bianchi; Xufeng Wei; Narayana Garimella; Bartley P Griffith; Zhongjun J Wu
Journal:  Artif Organs       Date:  2013-03-03       Impact factor: 3.094

9.  Effect of blood flow on platelets, leukocytes, and extracellular vesicles in thrombosis of simulated neonatal extracorporeal circulation.

Authors:  Andrew D Meyer; Anjana R Rishmawi; Robin Kamucheka; Crystal Lafleur; Andriy I Batchinsky; Nigel Mackman; Andrew P Cap
Journal:  J Thromb Haemost       Date:  2019-11-14       Impact factor: 5.824

10.  Toward an artificial endothelium: Development of blood-compatible surfaces for extracorporeal life support.

Authors:  Teryn R Roberts; Mark R S Garren; Hitesh Handa; Andriy I Batchinsky
Journal:  J Trauma Acute Care Surg       Date:  2020-08       Impact factor: 3.697

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.