Literature DB >> 16934093

Blood biocompatibility assessment of an intravenous gas exchange device.

Trevor A Snyder1, Heide J Eash, Kenneth N Litwak, Brian J Frankowski, Brack G Hattler, William J Federspiel, William R Wagner.   

Abstract

To treat acute lung failure, an intravenous membrane gas exchange device, the Hattler Catheter, is currently under development. Several methods were employed to evaluate the biocompatibility of the device during preclinical testing in bovines, and potential coatings for the fibers comprising the device were screened for their effectiveness in reducing thrombus deposition in vitro. Flow cytometric analysis demonstrated that the device had the capacity to activate platelets as evidenced by significant increases in circulating platelet microaggregates and activated platelets. Thrombus was observed on 20 +/- 6% of the surface area of devices implanted for up to 53 h. Adding aspirin to the antithrombotic therapy permitted two devices to remain implanted up to 96 h with reduced platelet activation and only 3% of the surface covered with thrombus. The application of heparin-based coatings significantly reduced thrombus deposition in vitro. The results suggest that with the use of appropriate antithrombotic therapies and surface coatings the Hattler Catheter might successfully provide support for acute lung failure without thrombotic complications.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16934093      PMCID: PMC1933496          DOI: 10.1111/j.1525-1594.2006.00281.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  14 in total

1.  Evaluation of local gas exchange in a pulsating respiratory support catheter.

Authors:  Heide J Eash; Brian J Frankowski; Brack G Hattler; William J Federspiel
Journal:  ASAIO J       Date:  2005 Mar-Apr       Impact factor: 2.872

Review 2.  Extracorporeal membrane oxygenation: a ten-year experience.

Authors:  G Mols; T Loop; K Geiger; E Farthmann; A Benzing
Journal:  Am J Surg       Date:  2000-08       Impact factor: 2.565

3.  Evaluation of plasma resistant hollow fiber membranes for artificial lungs.

Authors:  Heide J Eash; Heather M Jones; Brack G Hattler; William J Federspiel
Journal:  ASAIO J       Date:  2004 Sep-Oct       Impact factor: 2.872

4.  A respiratory gas exchange catheter: in vitro and in vivo tests in large animals.

Authors:  Brack G Hattler; Laura W Lund; Joseph Golob; Heide Russian; Michael F Lann; Thomas L Merrill; Brian Frankowski; William J Federspiel
Journal:  J Thorac Cardiovasc Surg       Date:  2002-09       Impact factor: 5.209

5.  Incidence, risk factors and outcome of barotrauma in mechanically ventilated patients.

Authors:  Antonio Anzueto; Fernando Frutos-Vivar; Andres Esteban; Inmaculada Alía; Laurent Brochard; Thomas Stewart; Salvador Benito; Martin J Tobin; Jose Elizalde; Fernando Palizas; Cide M David; Jorge Pimentel; Marco González; Luis Soto; Gabriel D'Empaire; Paolo Pelosi
Journal:  Intensive Care Med       Date:  2004-02-28       Impact factor: 17.440

6.  Flow cytometric assays to detect platelet activation and aggregation in device-implanted calves.

Authors:  L C Baker; W C Davis; J Autieri; M J Watach; K Yamazaki; P Litwak; W R Wagner
Journal:  J Biomed Mater Res       Date:  1998-08

Review 7.  Ventilator-induced lung injury.

Authors:  Alexander B Adams; Dana A Simonson; David J Dries
Journal:  Respir Care Clin N Am       Date:  2003-09

8.  Intravenacaval membrane oxygenation and carbon dioxide removal in severe acute respiratory failure.

Authors:  S A Conrad; J M Eggerstedt; L R Grier; V F Morris; M D Romero
Journal:  Chest       Date:  1995-06       Impact factor: 9.410

9.  Major findings from the clinical trials of the intravascular oxygenator.

Authors:  S A Conrad; A Bagley; B Bagley; R N Schaap
Journal:  Artif Organs       Date:  1994-11       Impact factor: 3.094

10.  Rate of thrombus accumulation on intravenacaval IVOX devices explanted from human clinical trial patients with acute respiratory failure.

Authors:  H Imai; R N Schaap; J D Mortensen
Journal:  Artif Organs       Date:  1994-11       Impact factor: 3.094

View more
  3 in total

1.  Thirty-day in-vivo performance of a wearable artificial pump-lung for ambulatory respiratory support.

Authors:  Zhongjun J Wu; Tao Zhang; Giacomo Bianchi; Xufeng Wei; Ho-Sung Son; Kang Zhou; Pablo G Sanchez; Jose Garcia; Bartley P Griffith
Journal:  Ann Thorac Surg       Date:  2011-11-25       Impact factor: 4.330

2.  Efficiency of gas transfer in venovenous extracorporeal membrane oxygenation: analysis of 317 cases with four different ECMO systems.

Authors:  Karla Lehle; Alois Philipp; Karl-Anton Hiller; Florian Zeman; Dirk Buchwald; Christof Schmid; Christian Dornia; Dirk Lunz; Thomas Müller; Matthias Lubnow
Journal:  Intensive Care Med       Date:  2014-10-17       Impact factor: 17.440

3.  Biocompatibility assessment of a long-term wearable artificial pump-lung in sheep.

Authors:  Kang Zhou; Shuqiong Niu; Giacomo Bianchi; Xufeng Wei; Narayana Garimella; Bartley P Griffith; Zhongjun J Wu
Journal:  Artif Organs       Date:  2013-03-03       Impact factor: 3.094

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.