Literature DB >> 23428650

Coronary artery stents: influence of adaptive statistical iterative reconstruction on image quality using 64-HDCT.

Cathérine Gebhard1, Michael Fiechter, Tobias A Fuchs, Julia Stehli, Ennio Müller, Barbara E Stähli, Caroline E Gebhard, Jelena R Ghadri, Bernd Klaeser, Oliver Gaemperli, Philipp A Kaufmann.   

Abstract

OBJECTIVE: The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT. METHODS AND
RESULTS: In 50 stents of 28 patients (mean age 64 ± 10 years) undergoing coronary CT angiography (CCTA) on an HDCT scanner the mean in-stent luminal diameter, stent length, image quality, in-stent contrast attenuation, and image noise were assessed. Studies were reconstructed using filtered back projection (FBP) and ASIR-FBP composites. ASIR resulted in reduced image noise vs. FBP (P < 0.0001). Two readers graded the CCTA stent image quality on a 4-point Likert scale and determined the proportion of interpretable stent segments. The best image quality for all clinical images was obtained with 40 and 60% ASIR with significantly larger luminal area visualization compared with FBP (+42.1 ± 5.4% with 100% ASIR vs. FBP alone; P < 0.0001) while the stent length was decreased (-4.7 ± 0.9%, <P = 0.002) and volume measurements were unaffected.
CONCLUSION: Reconstruction of CCTA from HDCT using 40 and 60% ASIR incrementally improves intra-stent luminal area, diameter visualization, and image quality compared with FBP reconstruction.

Entities:  

Keywords:  Adaptive statistical iterative reconstruction; Coronary CT angiography; Coronary artery stent

Mesh:

Year:  2013        PMID: 23428650     DOI: 10.1093/ehjci/jet013

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  9 in total

1.  Cone beam CT dose reduction in prostate radiotherapy using Likert scale methods.

Authors:  Keith A Langmack; Louise A Newton; Suzanne Jordan; Ruth Smith
Journal:  Br J Radiol       Date:  2015-12-21       Impact factor: 3.039

Review 2.  Image quality in coronary CT angiography: challenges and technical solutions.

Authors:  Olivier Ghekiere; Rodrigo Salgado; Nico Buls; Tim Leiner; Isabelle Mancini; Piet Vanhoenacker; Paul Dendale; Alain Nchimi
Journal:  Br J Radiol       Date:  2017-03-07       Impact factor: 3.039

3.  First in vivo head-to-head comparison of high-definition versus standard-definition stent imaging with 64-slice computed tomography.

Authors:  Tobias A Fuchs; Julia Stehli; Michael Fiechter; Svetlana Dougoud; Bert-Ram Sah; Cathérine Gebhard; Sacha Bull; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-01       Impact factor: 2.357

4.  Diagnostic performance of computed tomography angiography in the detection of coronary artery in-stent restenosis: evidence from an updated meta-analysis.

Authors:  Tao Dai; Jiang-Rong Wang; Peng-Fei Hu
Journal:  Eur Radiol       Date:  2017-11-09       Impact factor: 5.315

Review 5.  The role of advanced reconstruction algorithms in cardiac CT.

Authors:  Sandra S Halliburton; Yuki Tanabe; Sasan Partovi; Prabhakar Rajiah
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

6.  Novel Imaging Techniques for Heart Failure.

Authors:  Josep L Melero-Ferrer; Raquel López-Vilella; Herminio Morillas-Climent; Jorge Sanz-Sánchez; Ignacio J Sánchez-Lázaro; Luis Almenar-Bonet; Luis Martínez-Dolz
Journal:  Card Fail Rev       Date:  2016-05

7.  High-definition computed tomography for coronary artery stents: image quality and radiation doses for low voltage (100 kVp) and standard voltage (120 kVp) ECG-triggered scanning.

Authors:  Ji Won Lee; Chang Won Kim; Han Cheol Lee; Ming-Ting Wu; Lee Hwangbo; Ki Seok Choo; June Hong Kim; Ki-Nam Lee; Jin You Kim; Yeon Joo Jeong
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-29       Impact factor: 2.357

8.  Clinical applications of cardiac computed tomography: a consensus paper of the European Association of Cardiovascular Imaging-part I.

Authors:  Gianluca Pontone; Alexia Rossi; Marco Guglielmo; Marc R Dweck; Oliver Gaemperli; Koen Nieman; Francesca Pugliese; Pal Maurovich-Horvat; Alessia Gimelli; Bernard Cosyns; Stephan Achenbach
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2022-02-22       Impact factor: 6.875

9.  The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial.

Authors:  Sarah Feger; Matthias Rief; Elke Zimmermann; Peter Martus; Joanne Désirée Schuijf; Jörg Blobel; Felicitas Richter; Marc Dewey
Journal:  PLoS One       Date:  2015-05-06       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.