Literature DB >> 23416195

Initial fracture resistance and curing temperature rise of ten contemporary resin-based composites with increasing radiant exposure.

A Shortall1, W El-Mahy, D Stewardson, O Addison, W Palin.   

Abstract

OBJECTIVES: The principal objective of this study was to determine whether the bulk fracture resistance of ten light activated composites varied over a clinically realistic range of radiant exposures between 5 and 40 J/cm(2).
METHODS: Ten operators were tested for clinically simulated radiant exposure delivery from a Bluephase(®) (Ivoclar Vivadent, Schaan, Liechtenstein) LED light to an occlusal cavity floor in tooth 27 in a mannequin head using a MARC(®)-Patient Simulator (Bluelight Analytics Inc., Halifax, NS) device. Notch disc test samples were prepared to determine the torque resistance to fracture (T) of the composites. Samples were irradiated with the same monowave Bluephase(®) light for 10s, 20s or 40s at distances of 0mm or 7 mm. After 24h, storage samples were fractured in a universal testing machine and torque to failure was derived.
RESULTS: Radiant exposure delivered in the clinical simulation ranged from 14.3% to 69.4% of maximum mean radiant exposure deliverable at 0mm in a MARC(®)-Resin Calibrator (Bluelight Analytics Inc., Halifax, NS) test device. Mean torque to failure increased significantly (P<0.05) with radiant exposure for 8 out of 10 products. The micro-fine hybrid composite Gradia Direct anterior (GC) had the lowest mean (S.D.) T between 10.3 (1.8)N/mm and 13.7 (2.2)N/mm over the tested radiant exposure range. Three heavily filled materials Majesty Posterior, Clearfil APX and Clearfil Photo-Posterior (Kuraray) had mean T values in excess of 25 N/mm following 40 J/cm(2) radiant exposure. Mean T for Z100 (3MESPE) and Esthet-X (Dentsply) increased by 10% and 91% respectively over the tested range of radiant exposures.
CONCLUSIONS: Individual products require different levels of radiant exposure to optimize their fracture resistance. Light activated composites vary in the rate at which they attain optimal fracture resistance. CLINICAL SIGNIFICANCE: Unless the clinician accurately controls all the variables associated with energy delivery, there is no way of predicting that acceptable fracture resistance will be achieved intra-orally.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23416195     DOI: 10.1016/j.jdent.2013.02.002

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  14 in total

1.  Effect of mold type, diameter, and uncured composite removal method on depth of cure.

Authors:  Richard B Price; Frederick A Rueggeberg; Jessie Harlow; Braden Sullivan
Journal:  Clin Oral Investig       Date:  2015-12-03       Impact factor: 3.573

2.  Effect of different curing protocols on the mechanical properties of low-viscosity bulk-fill composites.

Authors:  Nicoleta Ilie; Katharina Stark
Journal:  Clin Oral Investig       Date:  2014-05-25       Impact factor: 3.573

3.  Effect of 457 nm diode-pumped solid state laser on the polymerization composite resins: microhardness, cross-link density, and polymerization shrinkage.

Authors:  Sung-Ae Son; Jeong-Kil Park; Kyoung-Hwa Jung; Ching-Chang Ko; Chang-Mo Jeong; Yong Hoon Kwon
Journal:  Photomed Laser Surg       Date:  2014-12-30       Impact factor: 2.796

4.  Guidelines for the selection, use, and maintenance of LED light-curing units - Part 1.

Authors:  A C Shortall; R B Price; L MacKenzie; F J T Burke
Journal:  Br Dent J       Date:  2016-10-21       Impact factor: 1.626

5.  The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites.

Authors:  Matej Par; Igor Repusic; Hrvoje Skenderovic; Ognjen Milat; Jelena Spajic; Zrinka Tarle
Journal:  Clin Oral Investig       Date:  2019-01-28       Impact factor: 3.573

6.  Irradiance of Different Curing Modes of Common Light Cure Devices: An In Vitro Study.

Authors:  Hani M Nassar; Mahmoud Almutairi; Albaraa Makhdom
Journal:  J Int Soc Prev Community Dent       Date:  2020-03-10

7.  Effect of High-Irradiance Light-Curing on Micromechanical Properties of Resin Cements.

Authors:  Anne Peutzfeldt; Adrian Lussi; Simon Flury
Journal:  Biomed Res Int       Date:  2016-12-04       Impact factor: 3.411

Review 8.  Utilizing Light Cure Units: A Concise Narrative Review.

Authors:  Fatin A Hasanain; Hani M Nassar
Journal:  Polymers (Basel)       Date:  2021-05-15       Impact factor: 4.329

9.  Real-Time Analysis of Temperature Changes in Composite Increments and Pulp Chamber during Photopolymerization.

Authors:  Ryan Jin-Young Kim; In-Bog Lee; Jin-Young Yoo; Su-Jung Park; Sin-Young Kim; Young-Ah Yi; Ji-Yun Hwang; Deog-Gyu Seo
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411

10.  Light-curing units used in dentistry: factors associated with heat development-potential risk for patients.

Authors:  Mathieu Mouhat; James Mercer; Lina Stangvaltaite; Ulf Örtengren
Journal:  Clin Oral Investig       Date:  2016-10-01       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.