Literature DB >> 8349721

Hip joint loading during walking and running, measured in two patients.

G Bergmann1, F Graichen, A Rohlmann.   

Abstract

The resultant hip joint force, its orientation and the moments were measured in two patients during walking and running using telemetering total hip prostheses. One patient underwent bilateral joint replacement and a second patient, additionally suffering from a neuropathic disease and atactic gait patterns, received one instrumented hip implant. The joint loading was observed over the first 30 and 18 months, respectively, following implantation. In the first patient the median peak forces increased with the walking speed from about 280% of the patient's body weight (BW) at 1 km h-1 to approximately 480% BW at 5 km h-1. Jogging and very fast walking both raised the forces to about 550% BW; stumbling on one occasion caused magnitudes of 720% BW. In the second patient median forces at 3 km h-1 were about 410% BW and a force of 870% BW was observed during stumbling. During all types of activities, the direction of the peak force in the frontal plane changed only slightly when the force magnitude was high. Perpendicular to the long femoral axis, the peak force acted predominantly from medial to lateral. The component from ventral to dorsal increased at higher force magnitudes. In one hip in the first patient and in the second patient the direction of large forces approximated the average anteversion of the natural femur. The torsional moments around the stem of the implant were 40.3 N m in the first patient and 24 N m in the second.

Entities:  

Mesh:

Year:  1993        PMID: 8349721     DOI: 10.1016/0021-9290(93)90058-m

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  146 in total

1.  Bone mineral density and serum testosterone in chronically trained, high mileage 40-55 year old male runners.

Authors:  K J MacKelvie; J E Taunton; H A McKay; K M Khan
Journal:  Br J Sports Med       Date:  2000-08       Impact factor: 13.800

2.  Cam FAI and Smaller Neck Angles Increase Subchondral Bone Stresses During Squatting: A Finite Element Analysis.

Authors:  K C Geoffrey Ng; Giulia Mantovani; Mario Lamontagne; Michel R Labrosse; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

Review 3.  Whole bone mechanics and bone quality.

Authors:  Jacqueline H Cole; Marjolein C H van der Meulen
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

4.  Is the rotation of the femoral head a potential initiation for cutting out? A theoretical and experimental approach.

Authors:  Andreas Lenich; Samuel Bachmeier; Lukas Prantl; Michael Nerlich; Jochen Hammer; Edgar Mayr; Amir Andreas Al-Munajjed; Bernd Füchtmeier
Journal:  BMC Musculoskelet Disord       Date:  2011-04-22       Impact factor: 2.362

Review 5.  The effects of exercise on human articular cartilage.

Authors:  F Eckstein; M Hudelmaier; R Putz
Journal:  J Anat       Date:  2006-04       Impact factor: 2.610

6.  Hip joint contact forces during stumbling.

Authors:  G Bergmann; F Graichen; A Rohlmann
Journal:  Langenbecks Arch Surg       Date:  2003-11-19       Impact factor: 3.445

7.  Anatomical and biomechanical investigations of the iliotibial tract.

Authors:  K Birnbaum; C H Siebert; T Pandorf; E Schopphoff; A Prescher; F U Niethard
Journal:  Surg Radiol Anat       Date:  2004-12       Impact factor: 1.246

8.  Friction in hip-joint prostheses and its influence on the fixation of the artificial head.

Authors:  R Schäfer; U Soltész; P F Bernard
Journal:  J Mater Sci Mater Med       Date:  1998-12       Impact factor: 3.896

9.  [Revision hip stems: an analysis of the fixation].

Authors:  M Thomsen; J P Kretzer; C Heisel; C Lee; J Nadorf; E Jakubowitz
Journal:  Orthopade       Date:  2010-06       Impact factor: 1.087

10.  A coupled mechano-biochemical model for bone adaptation.

Authors:  Václav Klika; Maria Angelés Pérez; José Manuel García-Aznar; František Maršík; Manuel Doblaré
Journal:  J Math Biol       Date:  2013-11-12       Impact factor: 2.259

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.