Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma.

Sen Bai1, Guangjun Li, Maojie Wang, Qinfeng Jiang, Yingjie Zhang, Yuquan Wei.   

Abstract

The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.
Copyright © 2013. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2013        PMID: 23402928     DOI: 10.1016/j.meddos.2012.10.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  11 in total

1.  Optimization of collimator angles in dual-arc volumetric modulated arc therapy planning for whole-brain radiotherapy with hippocampus and inner ear sparing.

Authors:  Wuji Sun; Kunzhi Chen; Yu Li; Wenming Xia; Lihua Dong; Yinghua Shi; Chao Ge; Xu Yang; Libo Wang; Huidong Wang
Journal:  Sci Rep       Date:  2021-09-24       Impact factor: 4.379

2.  A multi-institution evaluation of MLC log files and performance in IMRT delivery.

Authors:  James R Kerns; Nathan Childress; Stephen F Kry
Journal:  Radiat Oncol       Date:  2014-08-11       Impact factor: 3.481

3.  A model for preemptive maintenance of medical linear accelerators-predictive maintenance.

Authors:  Charles M Able; Alan H Baydush; Callistus Nguyen; Jacob Gersh; Alois Ndlovu; Igor Rebo; Jeremy Booth; Mario Perez; Benjamin Sintay; Michael T Munley
Journal:  Radiat Oncol       Date:  2016-03-10       Impact factor: 3.481

4.  MLC positional accuracy evaluation through the Picket Fence test on EBT2 films and a 3D volumetric phantom.

Authors:  Christos Antypas; Ioannis Floros; Maritina Rouchota; Christina Armpilia; Maria Lyra
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

5.  Appropriate reduction of the fragmentation level of subfield sequences to improve the accuracy of field delivery in IMRT for nasopharyngeal carcinoma.

Authors:  Yanze Sun; Gang Zhou; Yaqun Zhu; Li Zou; Ye Tian
Journal:  Br J Radiol       Date:  2020-02-12       Impact factor: 3.039

6.  Radiobiological effects of the interruption time with Monte Carlo Simulation on multiple fields in photon beams.

Authors:  Hisashi Nakano; Daisuke Kawahara; Satoshi Tanabe; Satoru Utsunomiya; Takeshi Takizawa; Madoka Sakai; Hirotake Saito; Atsushi Ohta; Motoki Kaidu; Hiroyuki Ishikawa
Journal:  J Appl Clin Med Phys       Date:  2020-12-03       Impact factor: 2.102

7.  Effect of Body Size Change on Off-Center Cervical Point and Face Doses in Patients Undergoing Nasopharyngeal Carcinoma Radiotherapy.

Authors:  Meifang Fang; Lu Xu; Xianxiang Wu; Zhen Cui; Zelai He; Haoxuan Zhang; Hao Jin
Journal:  Dis Markers       Date:  2022-04-25       Impact factor: 3.434

8.  Machine learning models to predict the delivered positions of Elekta multileaf collimator leaves for volumetric modulated arc therapy.

Authors:  Sruthi Sivabhaskar; Ruiqi Li; Arkajyoti Roy; Neil Kirby; Mohamad Fakhreddine; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2022-06-07       Impact factor: 2.243

9.  Operational consistency of medical linear accelerators manufactured and commissioned in series.

Authors:  Callistus M Nguyen; Alan H Baydush; James D Ververs; Scott Isom; Charles M Able; Michael T Munley
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2018-05-29

10.  Effect of MU-weighted multi-leaf collimator position error on dose distribution of SBRT radiotherapy in peripheral non-small cell lung cancer.

Authors:  AiHui Feng; Hua Chen; Hao Wang; HengLe Gu; Yan Shao; YanHua Duan; YanChen Ying; Ning Jeff Yue; ZhiYong Xu
Journal:  J Appl Clin Med Phys       Date:  2020-10-31       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.