Literature DB >> 23388958

A quantitative, non-interferometric X-ray phase contrast imaging technique.

Peter R T Munro1, Luigi Rigon, Konstantin Ignatyev, Frances C M Lopez, Diego Dreossi, Robert D Speller, Alessandro Olivo.   

Abstract

We present a quantitative, non-interferometric, X-ray differential phase contrast imaging technique based on the edge illumination principle. We derive a novel phase retrieval algorithm which requires only two images to be acquired and verify the technique experimentally using synchrotron radiation. The technique is useful for planar imaging but is expected to be important for quantitative phase tomography also. The properties and limitations of the technique are studied in detail.

Entities:  

Year:  2013        PMID: 23388958      PMCID: PMC3696730          DOI: 10.1364/OE.21.000647

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  14 in total

1.  Quantitative Phase Imaging Using Hard X Rays.

Authors: 
Journal:  Phys Rev Lett       Date:  1996-09-30       Impact factor: 9.161

2.  An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field.

Authors:  A Olivo; F Arfelli; G Cantatore; R Longo; R H Menk; S Pani; M Prest; P Poropat; L Rigon; G Tromba; E Vallazza; E Castelli
Journal:  Med Phys       Date:  2001-08       Impact factor: 4.071

3.  Low-dose, simple, and fast grating-based X-ray phase-contrast imaging.

Authors:  Peiping Zhu; Kai Zhang; Zhili Wang; Yijin Liu; Xiaosong Liu; Ziyu Wu; Samuel A McDonald; Federica Marone; Marco Stampanoni
Journal:  Proc Natl Acad Sci U S A       Date:  2010-07-19       Impact factor: 11.205

4.  Absorption, refraction and scattering in analyzer-based imaging: comparison of different algorithms.

Authors:  Paul Claude Diemoz; Paola Coan; Christian Glaser; Alberto Bravin
Journal:  Opt Express       Date:  2010-02-15       Impact factor: 3.894

5.  X-ray phase, absorption and scatter retrieval using two or more phase contrast images.

Authors:  Marcus J Kitchen; David M Paganin; Kentaro Uesugi; Beth J Allison; Robert A Lewis; Stuart B Hooper; Konstantin M Pavlov
Journal:  Opt Express       Date:  2010-09-13       Impact factor: 3.894

6.  Modelling of a novel x-ray phase contrast imaging technique based on coded apertures.

Authors:  A Olivo; R Speller
Journal:  Phys Med Biol       Date:  2007-10-23       Impact factor: 3.609

7.  X-ray phase imaging with a grating interferometer.

Authors:  Timm Weitkamp; Ana Diaz; Christian David; Franz Pfeiffer; Marco Stampanoni; Peter Cloetens; Eric Ziegler
Journal:  Opt Express       Date:  2005-08-08       Impact factor: 3.894

8.  Phase and absorption retrieval using incoherent X-ray sources.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Proc Natl Acad Sci U S A       Date:  2012-08-13       Impact factor: 11.205

9.  The relationship between wave and geometrical optics models of coded aperture type x-ray phase contrast imaging systems.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Opt Express       Date:  2010-03-01       Impact factor: 3.894

10.  Source size and temporal coherence requirements of coded aperture type x-ray phase contrast imaging systems.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Opt Express       Date:  2010-09-13       Impact factor: 3.894

View more
  2 in total

1.  On the possibility of quantitative refractive-index tomography of large biomedical samples with hard X-rays.

Authors:  Sergei Gasilov; Alberto Mittone; Emmanuel Brun; Alberto Bravin; Susanne Grandl; Paola Coan
Journal:  Biomed Opt Express       Date:  2013-08-02       Impact factor: 3.732

2.  Medicine, material science and security: the versatility of the coded-aperture approach.

Authors:  P R T Munro; M Endrizzi; P C Diemoz; C K Hagen; M B Szafraniec; T P Millard; C E Zapata; R D Speller; A Olivo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-01-27       Impact factor: 4.226

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.