Literature DB >> 20940891

X-ray phase, absorption and scatter retrieval using two or more phase contrast images.

Marcus J Kitchen1, David M Paganin, Kentaro Uesugi, Beth J Allison, Robert A Lewis, Stuart B Hooper, Konstantin M Pavlov.   

Abstract

We have developed two phase-retrieval techniques for analyser-based phase contrast imaging that provide information about an object's X-ray absorption, refraction and scattering properties. The first requires rocking curves to be measured with and without the sample and improves upon existing techniques by accurately fitting the curves with Pearson type VII functions. The second employs an iterative approach using two simultaneously recorded images by exploiting the Laue crystal geometry. This technique provides a substantial reduction in X-ray dose and enables quantitative phase retrieval to be performed on images of moving objects.

Entities:  

Mesh:

Year:  2010        PMID: 20940891     DOI: 10.1364/OE.18.019994

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  10 in total

1.  Phase and absorption retrieval using incoherent X-ray sources.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Proc Natl Acad Sci U S A       Date:  2012-08-13       Impact factor: 11.205

2.  Noise properties and task-based evaluation of diffraction-enhanced imaging.

Authors:  Jovan G Brankov; Alejandro Saiz-Herranz; Miles N Wernick
Journal:  J Med Imaging (Bellingham)       Date:  2014-11-11

3.  Effect of betamethasone, surfactant, and positive end-expiratory pressures on lung aeration at birth in preterm rabbits.

Authors:  Jessica R Crawshaw; Stuart B Hooper; Arjan B Te Pas; Beth A Allison; Megan J Wallace; Lauren T Kerr; Robert A Lewis; Colin J Morley; Andrew F Leong; Marcus J Kitchen
Journal:  J Appl Physiol (1985)       Date:  2016-07-08

4.  Medicine, material science and security: the versatility of the coded-aperture approach.

Authors:  P R T Munro; M Endrizzi; P C Diemoz; C K Hagen; M B Szafraniec; T P Millard; C E Zapata; R D Speller; A Olivo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-01-27       Impact factor: 4.226

5.  Dark-field tomography of an attenuating object using intrinsic x-ray speckle tracking.

Authors:  Samantha J Alloo; David M Paganin; Kaye S Morgan; Marcus J Kitchen; Andrew W Stevenson; Sheridan C Mayo; Heyang T Li; Ben M Kennedy; Anton Maksimenko; Joshua C Bowden; Konstantin M Pavlov
Journal:  J Med Imaging (Bellingham)       Date:  2022-02-07

6.  A quantitative, non-interferometric X-ray phase contrast imaging technique.

Authors:  Peter R T Munro; Luigi Rigon; Konstantin Ignatyev; Frances C M Lopez; Diego Dreossi; Robert D Speller; Alessandro Olivo
Journal:  Opt Express       Date:  2013-01-14       Impact factor: 3.894

7.  Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging.

Authors:  Keivan Majidi; Jun Li; Carol Muehleman; Jovan G Brankov
Journal:  Phys Med Biol       Date:  2014-03-20       Impact factor: 3.609

8.  Characterization of speckle in lung images acquired with a benchtop in-line x-ray phase-contrast system.

Authors:  A B Garson; E W Izaguirre; S G Price; M A Anastasio
Journal:  Phys Med Biol       Date:  2013-05-29       Impact factor: 3.609

9.  Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source.

Authors:  Simone Schleede; Felix G Meinel; Martin Bech; Julia Herzen; Klaus Achterhold; Guillaume Potdevin; Andreas Malecki; Silvia Adam-Neumair; Sven F Thieme; Fabian Bamberg; Konstantin Nikolaou; Alexander Bohla; Ali Ö Yildirim; Roderick Loewen; Martin Gifford; Ronald Ruth; Oliver Eickelberg; Maximilian Reiser; Franz Pfeiffer
Journal:  Proc Natl Acad Sci U S A       Date:  2012-10-16       Impact factor: 11.205

10.  Limited-angle tomography for analyzer-based phase-contrast x-ray imaging.

Authors:  Keivan Majidi; Miles N Wernick; Jun Li; Carol Muehleman; Jovan G Brankov
Journal:  Phys Med Biol       Date:  2014-06-05       Impact factor: 3.609

  10 in total