Literature DB >> 17975283

Modelling of a novel x-ray phase contrast imaging technique based on coded apertures.

A Olivo1, R Speller.   

Abstract

X-ray phase contrast imaging is probably the most relevant among emerging x-ray imaging techniques, and it has the proven potential of revolutionizing the field of diagnostic radiology. Impressive images of a wide range of samples have been obtained, mostly at synchrotron radiation facilities. The necessity of relying on synchrotron radiation has prevented to a large extent a widespread diffusion of phase contrast imaging, thus precluding its transfer to clinical practice. A new technique, based on the use of coded apertures, was recently developed at UCL. This technique was demonstrated to provide intense phase contrast signals with conventional x-ray sources and detectors. Unlike other attempts at making phase contrast imaging feasible with conventional sources, the coded-aperture approach does not impose substantial limitations and/or filtering of the radiation beam, and it therefore allows, for the first time, exposures compatible with clinical practice. The technique has been thoroughly modelled, and this paper describes the technique in detail by going through the different steps of the modelling. All the main factors influencing image quality are discussed, alongside the viability of realizing a prototype suitable for clinical use. The model has been experimentally validated and a section of the paper shows the comparison between simulated and experimental results.

Mesh:

Year:  2007        PMID: 17975283     DOI: 10.1088/0031-9155/52/22/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  Analytical reconstructions of intensity modulated x-ray phase-contrast imaging of human scale phantoms.

Authors:  Bartłomiej Włodarczyk; Jakub Pietrzak
Journal:  Biomed Opt Express       Date:  2015-10-05       Impact factor: 3.732

2.  Method for automatization of the alignment of a laboratory based x-ray phase contrast edge illumination system.

Authors:  T P Millard; M Endrizzi; K Ignatyev; C K Hagen; P R T Munro; R D Speller; A Olivo
Journal:  Rev Sci Instrum       Date:  2013-08       Impact factor: 1.523

3.  Phase and absorption retrieval using incoherent X-ray sources.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Proc Natl Acad Sci U S A       Date:  2012-08-13       Impact factor: 11.205

4.  Feasibility testing of a pre-clinical coded aperture phase contrast imaging configuration using a simple fast Monte Carlo simulator.

Authors:  Anthony Kavanagh; Alessandro Olivo; Robert Speller; Borivoj Vojnovic
Journal:  Biomed Opt Express       Date:  2013-12-04       Impact factor: 3.732

5.  Medicine, material science and security: the versatility of the coded-aperture approach.

Authors:  P R T Munro; M Endrizzi; P C Diemoz; C K Hagen; M B Szafraniec; T P Millard; C E Zapata; R D Speller; A Olivo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-01-27       Impact factor: 4.226

6.  Sensitivity of edge illumination X-ray phase-contrast imaging.

Authors:  P C Diemoz; M Endrizzi; A Bravin; I K Robinson; A Olivo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-01-27       Impact factor: 4.226

7.  Synchrotron- and laboratory-based X-ray phase-contrast imaging for imaging mouse articular cartilage in the absence of radiopaque contrast agents.

Authors:  Massimo Marenzana; Charlotte K Hagen; Patricia Das Neves Borges; Marco Endrizzi; Magdalena B Szafraniec; Tonia L Vincent; Luigi Rigon; Fulvia Arfelli; Ralf-Hendrik Menk; Alessandro Olivo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-01-27       Impact factor: 4.226

8.  The relationship between wave and geometrical optics models of coded aperture type x-ray phase contrast imaging systems.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Opt Express       Date:  2010-03-01       Impact factor: 3.894

9.  Design of a novel phase contrast x-ray imaging system for mammography.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Phys Med Biol       Date:  2010-07-05       Impact factor: 3.609

10.  A quantitative, non-interferometric X-ray phase contrast imaging technique.

Authors:  Peter R T Munro; Luigi Rigon; Konstantin Ignatyev; Frances C M Lopez; Diego Dreossi; Robert D Speller; Alessandro Olivo
Journal:  Opt Express       Date:  2013-01-14       Impact factor: 3.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.