Abstract

PURPOSE: Simultaneous insertion of multiple implants may exhibit suboptimal positions, especially in edentulous jaws considered for a fixed restoration. The aim of this study was to compare the incidence of and confounding factors in implant positioning errors related to the use of freehand and computer-aided treatment methods.
MATERIALS AND METHODS: A total of 353 implants were placed in 54 patients with at least one edentulous jaw using freehand and computer-aided methods involving 16 mucosa- and 12 bone-supported single- and multiple-type stereolithographic surgical guides. At the stage of prosthesis delivery, a blinded examiner evaluated seven positioning error criteria. Results were analyzed by chi-square test and logistic regression.
RESULTS: Interproximal emergence (OR = 2.82, P < .0001), insufficient interimplant distance (OR = 1.42, P < .0001), and improper parallelism (OR = 1.24, P = .001) errors were significantly higher in implants placed by the freehand method. The highest probability of positioning error (88%) was associated with the use of the freehand method, whereas the lowest (6%) was associated with single-type, mucosa-supported guides with other significant confounding factors.
CONCLUSION: Utilizing computer-aided methods may alleviate the occurrence of implant positioning errors that are frequently associated with the freehand method. The use of software planning with enhanced viewing capabilities and single-type, mucosa-supported stereolithographic surgical guides in suitable patients minimizes errors.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23377066     DOI: 10.11607/jomi.2691

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  7 in total

1.  Digital implant planning and guided implant surgery - workflow and reliability.

Authors:  O Schubert; J Schweiger; M Stimmelmayr; E Nold; J-F Güth
Journal:  Br Dent J       Date:  2019-01-25       Impact factor: 1.626

2.  Computer-aided flapless implant surgery and immediate loading. A technical note.

Authors:  Alfonso Baruffaldi; Pier Paolo Poli; Andrea Baruffaldi; Lorenzo Giberti; Maurizio Pigozzo; Carlo Maiorana
Journal:  Oral Maxillofac Surg       Date:  2016-04-05

3.  Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations.

Authors:  Pisut Thangwarawut; Pokpong Amornvit; Dinesh Rokaya; Sirichai Kiattavorncharoen
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

4.  Implant-Supported PMMA Monolithic Full-Arch Rehabilitation with Surgical Computer-Planned Guide and Immediate Provisional: A Case Report with One Year Follow-Up.

Authors:  Vincenzo Luca Zizzari; Gianmarco Tacconelli
Journal:  Case Rep Dent       Date:  2018-04-01

5.  Validation of an Intra-Oral Scan Method Versus Cone Beam Computed Tomography Superimposition to Assess the Accuracy between Planned and Achieved Dental Implants: A Randomized In Vitro Study.

Authors:  Alessio Franchina; Luigi V Stefanelli; Fabio Maltese; George A Mandelaris; Alessandro Vantaggiato; Michele Pagliarulo; Nicola Pranno; Edoardo Brauner; Francesca De Angelis; Stefano Di Carlo
Journal:  Int J Environ Res Public Health       Date:  2020-12-14       Impact factor: 3.390

6.  Factors Influencing the Accuracy of Freehand Implant Placement: A Prospective Clinical Study.

Authors:  Sigmar Schnutenhaus; Marie Wagner; Cornelia Edelmann; Ralph G Luthardt; Heike Rudolph
Journal:  Dent J (Basel)       Date:  2021-05-10

7.  Risks of angled implant placement on posterior mandible buccal/lingual plated perforation: A virtual immediate implant placement study using CBCT.

Authors:  Tian-You Wang; Po-Jan Kuo; Earl Fu; Hsin-Yu Kuo; Nancy Nie-Shiuh Chang; Min-Wen Fu; E-Chin Shen; Hsien-Chung Chiu
Journal:  J Dent Sci       Date:  2019-03-20       Impact factor: 2.080

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.