Literature DB >> 33542168

Validation of an Intra-Oral Scan Method Versus Cone Beam Computed Tomography Superimposition to Assess the Accuracy between Planned and Achieved Dental Implants: A Randomized In Vitro Study.

Alessio Franchina1, Luigi V Stefanelli2, Fabio Maltese3, George A Mandelaris4, Alessandro Vantaggiato5, Michele Pagliarulo6, Nicola Pranno2, Edoardo Brauner2, Francesca De Angelis2, Stefano Di Carlo2.   

Abstract

Computer aided implantology is the safest way to perform dental implants. The research of high accuracy represents a daily effort. The validated method to assess the accuracy of placed dental implants is the superimposition of a pre-operative and a post-operative cone beam computed tomography (CBCT) with planned and placed implants. This procedure is accountable for a biologic cost for the patient. To investigate alternative procedure for accuracy assessment, fifteen resin casts were printed. For each model, six implants were digitally planned and then placed following three different approaches: (a) template guided free hand, (b) static computer aided implantology (SCAI), and (c) dynamic computer aided implantology (DCAI). The placement accuracy of each implant was performed via two methods: the CBCT comparison described above and a matching between implant positions recovered from the original surgical plan with those obtained with a post-operative intraoral scan (IOS). Statistically significant mean differences between guided groups (SCAI and DCAI) and the free hand group were found at all considered deviations, while no differences resulted between the SCAI and DCAI approaches. Moreover, no mean statistically significant differences were found between CBCT and IOS assessment, confirming the validity of this new method.

Entities:  

Keywords:  accuracy; dynamic computer aided implantology; dynamic navigation implantology; intra-oral scanning; static computer aided implantology; superimposition; surgical guides

Mesh:

Substances:

Year:  2020        PMID: 33542168      PMCID: PMC7765074          DOI: 10.3390/ijerph17249358

Source DB:  PubMed          Journal:  Int J Environ Res Public Health        ISSN: 1660-4601            Impact factor:   3.390


  45 in total

1.  Flapless implant surgery using an image-guided system. A 1- to 4-year retrospective multicenter comparative clinical study.

Authors:  Marc Berdougo; Thomas Fortin; Eric Blanchet; Michel Isidori; Jean-Luc Bosson
Journal:  Clin Implant Dent Relat Res       Date:  2009-02-13       Impact factor: 3.932

Review 2.  Imaging techniques and image interpretation for dental implant treatment.

Authors:  C C Wyatt; M J Pharoah
Journal:  Int J Prosthodont       Date:  1998 Sep-Oct       Impact factor: 1.681

3.  The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis.

Authors:  Ali Tahmaseb; Viviane Wu; Daniel Wismeijer; Wim Coucke; Christopher Evans
Journal:  Clin Oral Implants Res       Date:  2018-10       Impact factor: 5.977

4.  Accuracy of the evaluation of implant position using a completely digital registration method compared with a radiographic method.

Authors:  Tianhong Tang; Luman Liao; Zhuoli Huang; Xiaoyu Gu; Xiuyin Zhang
Journal:  J Prosthet Dent       Date:  2019-04-09       Impact factor: 3.426

5.  Implant treatment in the edentulous maxillae: a 15-year follow-up study on 76 consecutive patients provided with fixed prostheses.

Authors:  Torsten Jemt; Jesper Johansson
Journal:  Clin Implant Dent Relat Res       Date:  2006       Impact factor: 3.932

6.  2D/3D accuracies of implant position after guided surgery using different surgical protocols: A retrospective study.

Authors:  C Monaco; A Arena; L Corsaletti; V Santomauro; P Venezia; R Cavalcanti; A Di Fiore; G Zucchelli
Journal:  J Prosthodont Res       Date:  2020-02-13       Impact factor: 4.642

7.  An alternative method to match planned and achieved positions of implants, after virtual planning using cone-beam CT data and surgical guide templates--a method reducing patient radiation exposure (part I).

Authors:  Hans-Joachim Nickenig; Stephan Eitner
Journal:  J Craniomaxillofac Surg       Date:  2009-11-24       Impact factor: 2.078

8.  Implant positioning errors in freehand and computer-aided placement methods: a single-blind clinical comparative study.

Authors:  Volkan Arisan; Cüneyt Z Karabuda; Emre Mumcu; Tayfun Özdemir
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Jan-Feb       Impact factor: 2.804

9.  Dynamic navigation: a prospective clinical trial to evaluate the accuracy of implant placement.

Authors:  Gerardo Pellegrino; Valerio Taraschi; Zacchino Andrea; Agnese Ferri; Claudio Marchetti
Journal:  Int J Comput Dent       Date:  2019       Impact factor: 1.883

10.  Accuracy Evaluation of 14 Maxillary Full Arch Implant Treatments Performed with Da Vinci Bridge: A Case Series.

Authors:  Luigi V Stefanelli; George A Mandelaris; Alessio Franchina; Dario Di Nardo; Massimo Galli; Michele Pagliarulo; Luca Testarelli; Stefano Di Carlo; Gianluca Gambarini
Journal:  Materials (Basel)       Date:  2020-06-22       Impact factor: 3.623

View more
  5 in total

1.  Analytical Modeling of the Interaction of a Four Implant-Supported Overdenture with Bone Tissue.

Authors:  Bohdan Pelekhan; Maciej Dutkiewicz; Ivan Shatskyi; Andrii Velychkovych; Mykola Rozhko; Liubomyr Pelekhan
Journal:  Materials (Basel)       Date:  2022-03-24       Impact factor: 3.623

2.  Influence of Implant Impression Methods, Polymer Materials, and Implant Angulation on the Accuracy of Dental Models.

Authors:  Daniela Djurovic Koprivica; Tatjana Puskar; Igor Budak; Mario Sokac; Milica Jeremic Knezevic; Aleksandra Maletin; Bojana Milekic; Djordje Vukelic
Journal:  Polymers (Basel)       Date:  2022-07-11       Impact factor: 4.967

3.  Intraoral Scanning as an Alternative to Evaluate the Accuracy of Dental Implant Placements in Partially Edentate Situations: A Prospective Clinical Case Series.

Authors:  Jan van Hooft; Guido Kielenstijn; Jeroen Liebregts; Frank Baan; Gert Meijer; Jan D'haese; Ewald Bronkhorst; Luc Verhamme
Journal:  J Clin Med       Date:  2022-10-05       Impact factor: 4.964

4.  Optimization of X-ray Investigations in Dentistry Using Optical Coherence Tomography.

Authors:  Ralph-Alexandru Erdelyi; Virgil-Florin Duma; Cosmin Sinescu; George Mihai Dobre; Adrian Bradu; Adrian Podoleanu
Journal:  Sensors (Basel)       Date:  2021-07-02       Impact factor: 3.847

5.  Assessment of Differences in the Dimensions of Mandible Condyle Models in Fan- versus Cone-Beam Computer Tomography Acquisition.

Authors:  Bartosz Bielecki-Kowalski; Marcin Kozakiewicz
Journal:  Materials (Basel)       Date:  2021-03-12       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.