Literature DB >> 23351465

Comparison of hemodynamic performance of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN aortic valves inserted by catheter for aortic stenosis.

Luis Nombela-Franco1, Marc Ruel, Sam Radhakrishnan, John G Webb, Marc Hansen, Marino Labinaz, Chris Thompson, Stephen Fremes, Eric Dumont, Robert DeLarochellière, Daniel Doyle, Marina Urena, Michael Mok, Henrique Barbosa Ribeiro, Idan Roifman, Stuart Watkins, Jean G Dumesnil, Philippe Pibarot, Josep Rodés-Cabau.   

Abstract

Transcatheter aortic valve implantation with the self-expandable CoreValve (CV) and the balloon-expandable Edwards SAPIEN (ES) bioprostheses has been widely used for the treatment of severe aortic stenosis. However, a direct comparison of the hemodynamic results associated with these 2 prostheses is lacking. The aim of the present study was to compare the hemodynamic performance of both bioprostheses. A total of 41 patients who underwent transcatheter aortic valve implantation with the CV prosthesis were matched 1:1 for prosthesis size (26 mm), aortic annulus size, left ventricular ejection fraction, body surface area, and body mass index with patients who underwent transcatheter aortic valve implantation with the ES prosthesis. Doppler-echocardiographic data were prospectively collected before the intervention and at hospital discharge, and all examinations were sent to, and analyzed in, a central echocardiography core laboratory. The mean transprosthetic residual gradient was lower (p = 0.024) in the CV group (7.9 ± 3.1 mm Hg) than in the ES group (9.7 ± 3.8 mm Hg). The effective orifice area tended to be greater in the CV group (1.58 ± 0.31 cm(2) vs 1.49 ± 0.24 cm(2), p = 0.10). The incidence of severe prosthesis-patient mismatch was, however, similar between the 2 groups (effective orifice area indexed to the body surface area ≤0.65 cm(2)/m(2); CV 9.8%, ES 9.8%, p = 1.0). The incidence of paravalvular aortic regurgitation was greater with the CV (grade 1 or more in 85.4%, grade 2 or more in 39%) than with the ES (grade 1 or more in 58.5%, grade 2 or more in 22%; p = 0.001). The number and extent of paravalvular leaks were greater in the CV group (p <0.01 for both comparisons). In conclusion, transcatheter aortic valve implantation with the CV prosthesis was associated with a lower residual gradient but a greater rate of paravalvular aortic regurgitation compared to the ES prosthesis. The potential clinical consequences of the differences in hemodynamic performance between these transcatheter heart valves needs to be addressed in future studies.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23351465     DOI: 10.1016/j.amjcard.2012.11.063

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  13 in total

1.  Head to head transcatheter heart valve comparisons: when theory becomes reality.

Authors:  Gabriela Tirado-Conte; German Armijo; Luis Nombela-Franco
Journal:  Cardiovasc Diagn Ther       Date:  2018-08

Review 2.  Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Authors:  Rebecca T Hahn; Susheel Kodali; Philippe Généreux; Martin Leon
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

3.  Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre.

Authors:  Dayimi Kaya; Zulkif Tanriverdi; Huseyin Dursun; Tugce Colluoglu
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-09       Impact factor: 2.357

4.  Balloon- or Self-Expandable TAVI: Clinical Equipoise?

Authors:  John Jose; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Interv Cardiol       Date:  2015-05

5.  Patient-prosthesis mismatch: surgical aortic valve replacement versus transcatheter aortic valve replacement in high risk patients with aortic stenosis.

Authors:  Ravi K Ghanta; Irving L Kron
Journal:  J Thorac Dis       Date:  2016-10       Impact factor: 2.895

Review 6.  Aortic regurgitation after transcatheter aortic valve implantation: mechanisms and implications.

Authors:  Barbara E Stähli; Willibald Maier; Roberto Corti; Thomas F Lüscher; Rolf Jenni; Felix C Tanner
Journal:  Cardiovasc Diagn Ther       Date:  2013-03

Review 7.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11

Review 8.  Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.

Authors:  Pier Pasquale Leone; Fabio Fazzari; Francesco Cannata; Jorge Sanz-Sanchez; Antonio Mangieri; Lorenzo Monti; Ottavia Cozzi; Giulio Giuseppe Stefanini; Renato Bragato; Antonio Colombo; Bernhard Reimers; Damiano Regazzoli
Journal:  Front Cardiovasc Med       Date:  2021-06-04

9.  TAVR update: Contemporary data from the UK TAVI and US TVT registries.

Authors:  Hussam S Suradi; Ziyad M Hijazi
Journal:  Glob Cardiol Sci Pract       Date:  2015-09-08

10.  Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis.

Authors:  Yan-Biao Liao; Yi-Jian Li; Li Jun-Li; Zhen-Gang Zhao; Xin Wei; Jiay-Yu Tsauo; Tian-Yuan Xiong; Yuan-Ning Xu; Yuan Feng; Mao Chen
Journal:  Sci Rep       Date:  2017-11-08       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.