Development of an anthropomorphic breast phantom.

C B Caldwell1, M J Yaffe.   

Abstract

A new technique for producing anthropomorphic radiologic phantoms is described. Information from a patient radiograph is used to design the phantom. Optical densities from a digitized radiograph are converted to thicknesses of a phantom material, with corrections for geometry, x-ray spectrum, and scatter. Numerically controlled machining techniques are used to transcribe the anatomic details into the phantom material. High spatial frequencies are reproduced separately from low spatial frequencies using photochemical techniques in order to replicate finer details in the phantom. The result is a phantom consisting of a number of overlays. Radiographs of a breast phantom produced using the technique are shown, energy equivalence to attenuation of breast tissue is assessed, and methods of incorporating fine detail and quantitative features in the phantom are suggested.

Entities:  

Mesh:

Year:  1990        PMID: 2333054     DOI: 10.1118/1.596506

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Parenchymal texture analysis in digital mammography: robust texture feature identification and equivalence across devices.

Authors:  Brad M Keller; Andrew Oustimov; Yan Wang; Jinbo Chen; Raymond J Acciavatti; Yuanjie Zheng; Shonket Ray; James C Gee; Andrew D A Maidment; Despina Kontos
Journal:  J Med Imaging (Bellingham)       Date:  2015-04-03

2.  Comparison of full-field digital mammography and screen-film mammography for detection and characterization of simulated small masses.

Authors:  Wei T Yang; Chao-Jen Lai; Gary J Whitman; William A Murphy; Mark J Dryden; Anne C Kushwaha; Aysegul A Sahin; Dennis Johnston; Peter J Dempsey; Chris C Shaw
Journal:  AJR Am J Roentgenol       Date:  2006-12       Impact factor: 3.959

3.  Comparison of slot scanning digital mammography system with full-field digital mammography system.

Authors:  Chao-Jen Lai; Chris C Shaw; William Geiser; Lingyun Chen; Elsa Arribas; Tanya Stephens; Paul L Davis; Geetha P Ayyar; Basak E Dogan; Victoria A Nguyen; Gary J Whitman; Wei T Yang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

4.  Characterization of a novel anthropomorphic plastinated lung phantom.

Authors:  Sungwon Yoon; Robert W Henry; Donna M Bouley; N Robert Bennett; Rebecca Fahrig
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  Development of a physical 3D anthropomorphic breast phantom.

Authors:  Ann-Katherine Carton; Predrag Bakic; Christer Ullberg; Helen Derand; Andrew D A Maidment
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

6.  Development of a patient-specific two-compartment anthropomorphic breast phantom.

Authors:  Nicolas D Prionas; George W Burkett; Sarah E McKenney; Lin Chen; Robin L Stern; John M Boone
Journal:  Phys Med Biol       Date:  2012-06-15       Impact factor: 3.609

7.  Reproducing two-dimensional mammograms with three-dimensional printed phantoms.

Authors:  Andreu Badal; Matthew Clark; Bahaa Ghammraoui
Journal:  J Med Imaging (Bellingham)       Date:  2018-07-12

8.  Role of equalisation mammography of dense breasts.

Authors:  D B Plewes; J M Sabol; I Soutar; A Chevrier; R Shumak
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

9.  Quantification of breast arterial calcification using full field digital mammography.

Authors:  Sabee Molloi; Tong Xu; Justin Ducote; Carlos Iribarren
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

10.  Validation of a mammographic image quality modification algorithm using 3D-printed breast phantoms.

Authors:  Joana Boita; Alistair Mackenzie; Ruben E van Engen; Mireille Broeders; Ioannis Sechopoulos
Journal:  J Med Imaging (Bellingham)       Date:  2021-05-20
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.