Literature DB >> 30035152

Reproducing two-dimensional mammograms with three-dimensional printed phantoms.

Andreu Badal1, Matthew Clark2, Bahaa Ghammraoui1.   

Abstract

Mammography is currently the standard imaging modality used to screen women for breast abnormalities, and, as a result, it is a tool of great importance for the early detection of breast cancer. Physical phantoms are commonly used as surrogates of breast tissue to evaluate some aspects of the performance of mammography systems. However, most phantoms do not reproduce the anatomic heterogeneity of real breasts. New fabrication technologies, such as three-dimensional (3-D) printing, have created the opportunity to build more complex, anatomically realistic breast phantoms that could potentially assist in the evaluation of mammography systems. The reproducibility and relative low cost of 3-D printed objects might also enable the development of collections of representative patient models that could be used to assess the effect of anatomical variability on system performance, hence making bench testing studies a step closer to clinical trials. The primary objective of this work is to present a simple, easily reproducible methodology to design and print 3-D objects that replicate the attenuation profile observed in real two-dimensional mammograms. The secondary objective is to evaluate the capabilities and limitations of the competing 3-D printing technologies and characterize the x-ray properties of the different materials they use. Printable phantoms can be created using the open-source code introduced, which processes a raw mammography image to estimate the amount of x-ray attenuation at each pixel, and outputs a triangle mesh object that encodes the observed attenuation map. The conversion from the observed pixel gray value to a column of printed material with equivalent attenuation requires certain assumptions and knowledge of multiple imaging system parameters, such as x-ray energy spectrum, source-to-object distance, compressed breast thickness, and average breast material attenuation. To validate the proposed methodology, x-ray projections of printed phantoms were acquired with a clinical mammography system. The quality of the printing process was evaluated by comparing the mammograms of the printed phantoms and the original mammograms used to create the phantoms. The structural similarity index and the root-mean-square error were used as objective metrics to compare the two images. A detailed description of the software, a characterization of the printed materials using x-ray spectroscopy, and an evaluation of the realism of the sample printed phantoms are presented.

Entities:  

Keywords:  breast phantoms; mammography; three-dimensional printing

Year:  2018        PMID: 30035152      PMCID: PMC6042055          DOI: 10.1117/1.JMI.5.3.033501

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  9 in total

1.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

2.  Three-dimensional Physical Modeling: Applications and Experience at Mayo Clinic.

Authors:  Jane S Matsumoto; Jonathan M Morris; Thomas A Foley; Eric E Williamson; Shuai Leng; Kiaran P McGee; Joel L Kuhlmann; Linda E Nesberg; Terri J Vrtiska
Journal:  Radiographics       Date:  2015 Nov-Dec       Impact factor: 5.333

3.  Volumetric breast density estimation from full-field digital mammograms.

Authors:  Saskia van Engeland; Peter R Snoeren; Henkjan Huisman; Carla Boetes; Nico Karssemeijer
Journal:  IEEE Trans Med Imaging       Date:  2006-03       Impact factor: 10.048

4.  penMesh--Monte Carlo radiation transport simulation in a triangle mesh geometry.

Authors:  Andreu Badal; Iacovos Kyprianou; Diem Phuc Banh; Aldo Badano; Josep Sempau
Journal:  IEEE Trans Med Imaging       Date:  2009-05-08       Impact factor: 10.048

5.  Development of a physical 3D anthropomorphic breast phantom.

Authors:  Ann-Katherine Carton; Predrag Bakic; Christer Ullberg; Helen Derand; Andrew D A Maidment
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

6.  Development of an anthropomorphic breast phantom.

Authors:  C B Caldwell; M J Yaffe
Journal:  Med Phys       Date:  1990 Mar-Apr       Impact factor: 4.071

7.  The Cancer Imaging Archive (TCIA): maintaining and operating a public information repository.

Authors:  Kenneth Clark; Bruce Vendt; Kirk Smith; John Freymann; Justin Kirby; Paul Koppel; Stephen Moore; Stanley Phillips; David Maffitt; Michael Pringle; Lawrence Tarbox; Fred Prior
Journal:  J Digit Imaging       Date:  2013-12       Impact factor: 4.056

8.  Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data.

Authors:  Nooshin Kiarashi; Adam C Nolte; Gregory M Sturgeon; William P Segars; Sujata V Ghate; Loren W Nolte; Ehsan Samei; Joseph Y Lo
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

9.  Feasibility of estimating volumetric breast density from mammographic x-ray spectra using a cadmium telluride photon-counting detector.

Authors:  Bahaa Ghammraoui; Andreu Badal; Stephen J Glick
Journal:  Med Phys       Date:  2018-06-03       Impact factor: 4.071

  9 in total
  1 in total

1.  Validation of a mammographic image quality modification algorithm using 3D-printed breast phantoms.

Authors:  Joana Boita; Alistair Mackenzie; Ruben E van Engen; Mireille Broeders; Ioannis Sechopoulos
Journal:  J Med Imaging (Bellingham)       Date:  2021-05-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.