Literature DB >> 23328563

Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis.

Petter Dyverfeldt1, Michael D Hope, Elaine E Tseng, David Saloner.   

Abstract

OBJECTIVES: The authors sought to measure the turbulent kinetic energy (TKE) in the ascending aorta of patients with aortic stenosis and to assess its relationship to irreversible pressure loss.
BACKGROUND: Irreversible pressure loss caused by energy dissipation in post-stenotic flow is an important determinant of the hemodynamic significance of aortic stenosis. The simplified Bernoulli equation used to estimate pressure gradients often misclassifies the ventricular overload caused by aortic stenosis. The current gold standard for estimation of irreversible pressure loss is catheterization, but this method is rarely used due to its invasiveness. Post-stenotic pressure loss is largely caused by dissipation of turbulent kinetic energy into heat. Recent developments in magnetic resonance flow imaging permit noninvasive estimation of TKE.
METHODS: The study was approved by the local ethics review board and all subjects gave written informed consent. Three-dimensional cine magnetic resonance flow imaging was used to measure TKE in 18 subjects (4 normal volunteers, 14 patients with aortic stenosis with and without dilation). For each subject, the peak total TKE in the ascending aorta was compared with a pressure loss index. The pressure loss index was based on a previously validated theory relating pressure loss to measures obtainable by echocardiography.
RESULTS: The total TKE did not appear to be related to global flow patterns visualized based on magnetic resonance-measured velocity fields. The TKE was significantly higher in patients with aortic stenosis than in normal volunteers (p < 0.001). The peak total TKE in the ascending aorta was strongly correlated to index pressure loss (R(2) = 0.91).
CONCLUSIONS: Peak total TKE in the ascending aorta correlated strongly with irreversible pressure loss estimated by a well-established method. Direct measurement of TKE by magnetic resonance flow imaging may, with further validation, be used to estimate irreversible pressure loss in aortic stenosis.
Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23328563      PMCID: PMC3624082          DOI: 10.1016/j.jcmg.2012.07.017

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  38 in total

1.  "Overestimation" of catheter gradients by Doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery.

Authors:  H Baumgartner; T Stefenelli; J Niederberger; H Schima; G Maurer
Journal:  J Am Coll Cardiol       Date:  1999-05       Impact factor: 24.094

2.  Influence of structural geometry on the severity of bicuspid aortic stenosis.

Authors:  Kathryn E Richards; Dimitri Deserranno; Erwan Donal; Neil L Greenberg; James D Thomas; Mario J Garcia
Journal:  Am J Physiol Heart Circ Physiol       Date:  2004-04-29       Impact factor: 4.733

3.  PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography.

Authors:  Tianliang Gu; Frank R Korosec; Walter F Block; Sean B Fain; Quill Turk; Darren Lum; Yong Zhou; Thomas M Grist; Victor Haughton; Charles A Mistretta
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

4.  Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase-contrast MRI.

Authors:  Petter Dyverfeldt; Andreas Sigfridsson; John-Peder Escobar Kvitting; Tino Ebbers
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

Review 5.  Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice.

Authors:  Helmut Baumgartner; Judy Hung; Javier Bermejo; John B Chambers; Arturo Evangelista; Brian P Griffin; Bernard Iung; Catherine M Otto; Patricia A Pellikka; Miguel Quiñones
Journal:  Eur J Echocardiogr       Date:  2008-12-08

6.  Pressure recovery in aortic valve stenosis.

Authors:  W K Laskey; W G Kussmaul
Journal:  Circulation       Date:  1994-01       Impact factor: 29.690

7.  A new perivascular multi-element pulsed Doppler ultrasound system for in vivo studies of velocity fields and turbulent stresses in large vessels.

Authors:  H Nygaard; J M Hasenkam; E M Pedersen; W Y Kim; P K Paulsen
Journal:  Med Biol Eng Comput       Date:  1994-01       Impact factor: 2.602

8.  Extent, determinants and clinical importance of pressure recovery in patients with aortic valve stenosis.

Authors:  W A Schöbel; W Voelker; K K Haase; K R Karsch
Journal:  Eur Heart J       Date:  1999-09       Impact factor: 29.983

9.  Quantification of aortic valve area and left ventricular muscle mass in healthy subjects and patients with symptomatic aortic valve stenosis by MRI.

Authors:  J Haimerl; A Freitag-Krikovic; A Rauch; E Sauer
Journal:  Z Kardiol       Date:  2005-03

10.  Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI.

Authors:  Petter Dyverfeldt; John-Peder Escobar Kvitting; Andreas Sigfridsson; Jan Engvall; Ann F Bolger; Tino Ebbers
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

View more
  44 in total

1.  Re: Blood flow analysis of the aortic arch using computational fluid dynamics.

Authors:  Michael Markl; Gregory J Wagner; Alex J Barker
Journal:  Eur J Cardiothorac Surg       Date:  2016-01-27       Impact factor: 4.191

2.  Extended 3D approach for quantification of abnormal ascending aortic flow.

Authors:  Monica Sigovan; Petter Dyverfeldt; Jarrett Wrenn; Elaine E Tseng; David Saloner; Michael D Hope
Journal:  Magn Reson Imaging       Date:  2015-02-23       Impact factor: 2.546

3.  4-D flow magnetic-resonance-imaging-derived energetic biomarkers are abnormal in children with repaired tetralogy of Fallot and associated with disease severity.

Authors:  Joshua D Robinson; Michael J Rose; Maria Joh; Kelly Jarvis; Susanne Schnell; Alex J Barker; Cynthia K Rigsby; Michael Markl
Journal:  Pediatr Radiol       Date:  2018-12-01

4.  Viscous energy loss in the presence of abnormal aortic flow.

Authors:  Alex J Barker; Pim van Ooij; Krishna Bandi; Julio Garcia; Mazen Albaghdadi; Patrick McCarthy; Robert O Bonow; James Carr; Jeremy Collins; S Chris Malaisrie; Michael Markl
Journal:  Magn Reson Med       Date:  2013-10-02       Impact factor: 4.668

Review 5.  4D flow imaging: current status to future clinical applications.

Authors:  Michael Markl; Susanne Schnell; Alex J Barker
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

6.  Assessment of altered three-dimensional blood characteristics in aortic disease by velocity distribution analysis.

Authors:  Julio Garcia; Alex J Barker; Pim van Ooij; Susanne Schnell; Jyothy Puthumana; Robert O Bonow; Jeremy D Collins; James C Carr; Michael Markl
Journal:  Magn Reson Med       Date:  2014-09-23       Impact factor: 4.668

7.  Abnormal aortic flow conduction is associated with increased viscous energy loss in patients with repaired tetralogy of Fallot.

Authors:  Michal Schäfer; Alex J Barker; James Jaggers; Gareth J Morgan; Matthew L Stone; Uyen Truong; Lorna P Browne; Ladonna Malone; D Dunbar Ivy; Max B Mitchell
Journal:  Eur J Cardiothorac Surg       Date:  2020-03-01       Impact factor: 4.191

8.  Association between flow skewness and aortic dilatation in patients with aortic stenosis.

Authors:  Hojin Ha; Hyun Jung Koo; June Goo Lee; Guk Bae Kim; Jihoon Kweon; Sang Joon Lee; Joon Won Kang; Tae Hwan Lim; Dae Hee Kim; Jong Min Song; Duk Hyun Kang; Jae Kwan Song; Young Hak Kim; Namkug Kim; Dong Hyun Yang
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-16       Impact factor: 2.357

9.  In vitro evaluation of flow patterns and turbulent kinetic energy in trans-catheter aortic valve prostheses.

Authors:  Daniel Giese; Kilian Weiss; Bettina Baeßler; Navid Madershahian; Yeong-Hoon Choi; David Maintz; Alexander C Bunck
Journal:  MAGMA       Date:  2017-09-18       Impact factor: 2.310

Review 10.  Noninvasive Imaging of Flow and Vascular Function in Disease of the Aorta.

Authors:  Matthew C Whitlock; W Gregory Hundley
Journal:  JACC Cardiovasc Imaging       Date:  2015-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.