Literature DB >> 23271447

Simulation system for understanding the lag effect in fluoroscopic images.

Rie Tanaka1, Hiroki Kawashima, Katsuhiro Ichikawa, Kosuke Matsubara, Hiroji Iida, Shigeru Sanada.   

Abstract

Real-time tumor tracking in external radiotherapy can be achieved by diagnostic (kV) X-ray imaging with a dynamic flat-panel detector (FPD). It is crucial to understand the effects of image lag for real-time tumor tracking. Our purpose in this study was to develop a lag simulation system based on the image lag properties of an FPD system. Image lag properties were measured on flat-field images both in direct- and indirect-conversion dynamic FPDs. A moving target with image lag was simulated based on the lag properties in all combinations of FPD types, imaging rates, exposure doses, and target speeds, and then compared with actual moving targets for investigation of the reproducibility of image lag. Image lag was simulated successfully and agreed well with the actual lag as well as with the predicted effect. In the indirect-conversion FPD, a higher dose caused greater image lag on images. In contrast, there were no significant differences among dose levels in a direct-conversion FPD. There were no relationships between target speed and amount of image blurring in either type of FPD. The maximum contour blurring and the rate of increase in pixel value due to image lag were 1.1 mm and 10.0 %, respectively, in all combinations of imaging parameters examined in this study. Blurred boundaries and changes in pixel value due to image lag were estimated under various imaging conditions with use of the simulation system. Our system would be helpful for a better understanding of the effects of image lag in fluoroscopic images.

Entities:  

Mesh:

Year:  2012        PMID: 23271447     DOI: 10.1007/s12194-012-0196-8

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  9 in total

1.  A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager.

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  1999-08       Impact factor: 4.071

2.  Flat-panel cone-beam computed tomography for image-guided radiation therapy.

Authors:  David A Jaffray; Jeffrey H Siewerdsen; John W Wong; Alvaro A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-08-01       Impact factor: 7.038

3.  Investigation on effect of image lag in fluoroscopic images obtained with a dynamic flat-panel detector (FPD) on accuracy of target tracking in radiotherapy.

Authors:  Rie Tanaka; Katsuhiro Ichikawa; Shinichiro Mori; Suguru Dobashi; Motoki Kumagai; Hiroki Kawashima; Shinichi Minohara; Sigeru Sanada
Journal:  J Radiat Res       Date:  2010-10-23       Impact factor: 2.724

Review 4.  Dynamic targeting image-guided radiotherapy.

Authors:  Calvin Huntzinger; Peter Munro; Scott Johnson; Mika Miettinen; Corey Zankowski; Greg Ahlstrom; Reto Glettig; Reto Filliberti; Wolfgang Kaissl; Martin Kamber; Martin Amstutz; Lionel Bouchet; Dan Klebanov; Hassan Mostafavi; Richard Stark
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

Review 5.  Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy.

Authors:  C J Moore; A Amer; T Marchant; J R Sykes; J Davies; J Stratford; C McCarthy; C MacBain; A Henry; P Price; P C Williams
Journal:  Br J Radiol       Date:  2006-09       Impact factor: 3.039

6.  Development of quality control system for flat-panel detectors.

Authors:  Atsushi Teramoto; Takahiko Kajihara; Shoichi Suzuki; Kazuo Kinoshita; Masatoshi Tsuzaka; Hiroshi Fujita
Journal:  Radiol Phys Technol       Date:  2011-03-17

7.  Lag and ghosting in a clinical flat-panel selenium digital mammography system.

Authors:  Aili K Bloomquist; Martin J Yaffe; Gordon E Mawdsley; David M Hunter; Daniel J Beideck
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

8.  Lag measurement in an a-Se active matrix flat-panel imager.

Authors:  C Schroeder; T Stanescu; S Rathee; B G Fallone
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

Review 9.  The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography.

Authors:  A R Cowen; A G Davies; M U Sivananthan
Journal:  Clin Radiol       Date:  2008-10       Impact factor: 2.350

  9 in total