Literature DB >> 2326480

Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid.

E M Haacke1, P A Wielopolski, J A Tkach, M T Modic.   

Abstract

The authors discuss the appropriate FISP (fast imaging with steady-state precession) sequence structure to maintain constant phase at the radio-frequency pulse in the presence of motion. They present preliminary results of its application to head and spine imaging in an effort to maintain contrast between the cerebrospinal fluid (CSF) and the soft tissue. In the usual application of these FISP-like sequences, the gradient structure is modified to avoid unwanted signal (and contrast) variations due to field inhomogeneities. This change makes the signal sensitive to motion with a resulting decrease in signal intensity for moving tissue. The expected high contrast at large flip angles for tissues with low T1/T2 ratios such as CSF is not obtained. The technique discussed here overcomes the effects of field inhomogeneities and compensates for moving spins so that the transverse steady-state equilibrium and hence high contrast are obtained simultaneously.

Mesh:

Year:  1990        PMID: 2326480     DOI: 10.1148/radiology.175.2.2326480

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  40 in total

Review 1.  Review of new techniques in echocardiography and magnetic resonance imaging as applied to patients with congenital heart disease.

Authors:  D J Sahn; G W Vick
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

2.  Three-dimensional true FISP for high-resolution imaging of the whole brain.

Authors:  B Schmitz; T Hagen; W Reith
Journal:  Eur Radiol       Date:  2003-02-26       Impact factor: 5.315

3.  MR-guided catheter navigation of the intracranial subarachnoid space.

Authors:  George Rappard; Gregory J Metzger; James L Fleckenstein; Evelyn E Babcock; Paul T Weatherall; Robert E Replogle; G Lee Pride; Susan L Miller; Christina E Adams; Phillip D Purdy
Journal:  AJNR Am J Neuroradiol       Date:  2003-04       Impact factor: 3.825

4.  Evaluation of lumber nerve root compression using thin-slice thickness coronal magnetic resonance imaging: three-dimensional fat-suppressed multi-shot balanced non-steady-state free precession versus three-dimensional T1-weighted spoiled gradient-recalled echo.

Authors:  Keizo Tanitame; Nobuko Tanitame; Chihiro Tani; Masaki Ishikawa; Miyuki Takasu; Shuji Date; Keiko Otani; Kazuo Awai
Journal:  Jpn J Radiol       Date:  2011-09-29       Impact factor: 2.374

5.  TrueFisp versus HASTE sequences in 3T cine MRI: Evaluation of image quality during phonation in patients with velopharyngeal insufficiency.

Authors:  Christiane Kulinna-Cosentini; Christian Czerny; Arnulf Baumann; Michael Weber; Klaus Sinko
Journal:  Eur Radiol       Date:  2015-11-28       Impact factor: 5.315

6.  Comparison of wideband steady-state free precession and T₂-weighted fast spin echo in spine disorder assessment at 1.5 and 3 T.

Authors:  Giovanna S Danagoulian; Lei Qin; Krishna S Nayak; Rivka R Colen; Srinivasan Mukundan; Mitchell B Harris; Ferenc A Jolesz; Ajit Shankaranarayanan; William A Copen; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2012-01-27       Impact factor: 4.668

7.  MR ventriculocisternography by using 3D balanced steady-state free precession imaging: technical note.

Authors:  Ming-Long Wu; Cheng-Wen Ko; Ting-Yi Chen; Ming-Ting Wu; Hsiao-Wen Chung; Teng-Yi Huang; Yi-Ru Lin
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

8.  Feasibility of in vivo structural analysis of high-resolution magnetic resonance images of the proximal femur.

Authors:  Roland Krug; S Banerjee; E T Han; D C Newitt; T M Link; S Majumdar
Journal:  Osteoporos Int       Date:  2005-07-06       Impact factor: 4.507

9.  A noncontrast-enhanced pulse sequence optimized to visualize human peripheral vessels.

Authors:  Kjell-Inge Gjesdal; Tryggve Storaas; Jonn-Terje Geitung
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

10.  Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint.

Authors:  Robert Stahl; Roland Krug; Douglas A C Kelley; Jin Zuo; C Benjamin Ma; Sharmila Majumdar; Thomas M Link
Journal:  Skeletal Radiol       Date:  2009-03-18       Impact factor: 2.199