A noncontrast-enhanced pulse sequence optimized to visualize human peripheral vessels.

Kjell-Inge Gjesdal1, Tryggve Storaas, Jonn-Terje Geitung.   

Abstract

The purpose of this paper is to present a pulse sequence optimized to visualize human peripheral vessels. The optimized MR technique is a 3D multi-shot balanced non-SSFP gradient echo pulse sequence with fat suppression. Several imaging parameters were adjusted to find the best compromise between the contrast of vascular structures and muscle, fat, and bone. Most of the optimization was performed in the knee and calf regions using multi-channel SENSE coils. To verify potential clinical use, images of both healthy volunteers and volunteers with varicose veins were produced. The balanced non-SSFP sequence can produce high-spatial-resolution images of the human peripheral vessels without the need for an intravenous contrast agent. Both arteries and veins are displayed along with other body fluids. Due to the high spatial resolution of the axial plane source or reconstructed images, the need for procedures to separate arteries from veins is limited. We demonstrate that high signals from synovial joint fluid and cystic structures can be suppressed by applying an inversion prepulse but at the expense of reduced image signal-to-noise and overall image quality.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18704438     DOI: 10.1007/s00330-008-1113-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

Review 1.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

2.  MR coronary angiography using 3D-SSFP with and without contrast application.

Authors:  Anja Zagrosek; Ralph Noeske; Hassan Abdel-Aty; Matthias G Friedrich; Rainer Dietz; Jeanette Schulz-Menger
Journal:  J Cardiovasc Magn Reson       Date:  2005       Impact factor: 5.364

Review 3.  Peripheral MR angiography.

Authors:  Hale Ersoy; HongLei Zhang; Martin R Prince
Journal:  J Cardiovasc Magn Reson       Date:  2006       Impact factor: 5.364

4.  Extracranial carotid arteries: evaluation with "black blood" MR angiography.

Authors:  R R Edelman; H P Mattle; B Wallner; R Bajakian; J Kleefield; C Kent; J J Skillman; J B Mendel; D J Atkinson
Journal:  Radiology       Date:  1990-10       Impact factor: 11.105

5.  Gadolinium-enhanced body MR venography with subtraction technique.

Authors:  J A Lebowitz; N M Rofsky; G A Krinsky; J C Weinreb
Journal:  AJR Am J Roentgenol       Date:  1997-09       Impact factor: 3.959

6.  Pelvic and lower extremity veins: contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience.

Authors:  S G Ruehm; W Wiesner; J F Debatin
Journal:  Radiology       Date:  2000-05       Impact factor: 11.105

7.  High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: initial experience.

Authors:  Konstantin Nikolaou; Harald Kramer; Christina Grosse; Dirk Clevert; Olaf Dietrich; Mike Hartmann; Paul Chamberlin; Stefan Assmann; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Radiology       Date:  2006-10-10       Impact factor: 11.105

8.  MR-venography using high resolution True-FISP.

Authors:  E Spuentrup; A Buecker; M Stuber; R W Günther
Journal:  Rofo       Date:  2001-08

9.  Detection of deep venous thrombosis: prospective comparison of MR imaging and sonography.

Authors:  A J Evans; H D Sostman; L A Witty; E K Paulson; C E Spritzer; B S Hertzberg; B A Carroll; V F Tapson; H A Saltzman; D M DeLong
Journal:  J Magn Reson Imaging       Date:  1996 Jan-Feb       Impact factor: 4.813

Review 10.  Technical requirements, biophysical considerations and protocol optimization with magnetic resonance angiography using blood-pool agents.

Authors:  Martin Rohrer; Liesbeth Geerts-Ossevoort; Gerhard Laub
Journal:  Eur Radiol       Date:  2007-03       Impact factor: 5.315

View more
  4 in total

1.  Evaluation of lumber nerve root compression using thin-slice thickness coronal magnetic resonance imaging: three-dimensional fat-suppressed multi-shot balanced non-steady-state free precession versus three-dimensional T1-weighted spoiled gradient-recalled echo.

Authors:  Keizo Tanitame; Nobuko Tanitame; Chihiro Tani; Masaki Ishikawa; Miyuki Takasu; Shuji Date; Keiko Otani; Kazuo Awai
Journal:  Jpn J Radiol       Date:  2011-09-29       Impact factor: 2.374

2.  Diagnostic cross-sectional imaging of arterial diseases: really noninvasive?

Authors:  Jean-Pierre Laissy; Nicoletta Pasi; Jean-Michel Serfaty
Journal:  Eur Radiol       Date:  2010-11-15       Impact factor: 5.315

3.  The benefit of non contrast-enhanced magnetic resonance angiography for predicting vascular access surgery outcome: a computer model perspective.

Authors:  Maarten A G Merkx; Wouter Huberts; E Mariëlle H Bosboom; Aron S Bode; Javier Oliván Bescós; Jan H M Tordoir; Marcel Breeuwer; Frans N van de Vosse
Journal:  PLoS One       Date:  2013-02-04       Impact factor: 3.240

4.  Comparison with Magnetic Resonance Three-Dimensional Sequence for Lumbar Nerve Root with Intervertebral Foramen.

Authors:  Hiroyuki Takashima; Tsuneo Takebayashi; Hiroki Shishido; Mitsunori Yoshimoto; Rui Imamura; Yoshihiro Akatsuka; Yoshinori Terashima; Hiroyoshi Fujiwara; Masateru Nagae; Toshikazu Kubo; Toshihiko Yamashita
Journal:  Asian Spine J       Date:  2016-02-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.