Literature DB >> 23263409

An evaluation of luminol formulations and their effect on DNA profiling.

Gnyaneshwari Patel1, Andy Hopwood.   

Abstract

Luminol is a presumptive test reagent used for the location of latent bloodstains. Various formulations are used by different forensic practitioners and commercial products are also widely available. There is little concurrence between authors with regards to the sensitivity limits of luminol which can vary significantly depending upon the substrate. We evaluated the sensitivity and stability of five different luminol formulations on a range of blood dilutions. All formulations showed an overall decrease in performance over 24 h though the effect was more gradual on a non-porous surface compared to porous. We found that BlueStar® Magnum showed the greatest sensitivity compared to other formulations and detected 50 μl of 1/100,000 blood dilutions on both porous and non-porous surfaces. Two formulations of luminol were selected based on the result of the sensitivity and stability study and were assessed for their impact on the DNA profiling process. There was a statistically significant improvement in DNA profile peak area from luminol-treated samples when compared to control samples of neat blood stains. However, at the weaker blood dilution of 1/1,000, the difference between control and luminol-treated samples was dependent on the substrate type with porous (fabric) samples showing a significant difference and non-porous (tile) swabbed samples requiring further work to conclusively ascertain the effect.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23263409     DOI: 10.1007/s00414-012-0800-9

Source DB:  PubMed          Journal:  Int J Legal Med        ISSN: 0937-9827            Impact factor:   2.686


  8 in total

1.  A novel approach to obtaining reliable PCR results from luminol treated bloodstains.

Authors:  A Della Manna; S Montpetit
Journal:  J Forensic Sci       Date:  2000-07       Impact factor: 1.832

2.  A study of common interferences with the forensic luminol test for blood.

Authors:  T I Quickenden; J I Creamer
Journal:  Luminescence       Date:  2001 Jul-Aug       Impact factor: 2.464

3.  The presumptive reagent fluorescein for detection of dilute bloodstains and subsequent STR typing of recovered DNA.

Authors:  B Budowle; J L Leggitt; D A Defenbaugh; K M Keys; S F Malkiewicz
Journal:  J Forensic Sci       Date:  2000-09       Impact factor: 1.832

4.  Evaluation of six presumptive tests for blood, their specificity, sensitivity, and effect on high molecular-weight DNA.

Authors:  Shanan S Tobe; Nigel Watson; Niamh Nic Daéid
Journal:  J Forensic Sci       Date:  2007-01       Impact factor: 1.832

5.  Chemiluminescence in the visualization of forensic bloodstains.

Authors:  L T Lytle; D G Hedgecock
Journal:  J Forensic Sci       Date:  1978-07       Impact factor: 1.832

6.  Fingerprint enhancement revisited and the effects of blood enhancement chemicals on subsequent profiler Plus fluorescent short tandem repeat DNA analysis of fresh and aged bloody fingerprints.

Authors:  C J Frégeau; O Germain; R M Fourney
Journal:  J Forensic Sci       Date:  2000-03       Impact factor: 1.832

7.  Forensic application of the luminol reaction as a presumptive test for latent blood detection.

Authors:  Filippo Barni; Simon W Lewis; Andrea Berti; Gordon M Miskelly; Giampietro Lago
Journal:  Talanta       Date:  2007-01-09       Impact factor: 6.057

Review 8.  Illuminating the health and safety of luminol.

Authors:  Tony Larkin; Chris Gannicliffe
Journal:  Sci Justice       Date:  2008-06       Impact factor: 2.124

  8 in total
  4 in total

1.  Detectability, visualization, and DNA analysis of bloodstains after repainting the walls.

Authors:  Frank Ramsthaler; Julia Schlote; Axel Gehl; Sabine Cappel-Hoffmann; Mattias Kettner
Journal:  Int J Legal Med       Date:  2018-08-09       Impact factor: 2.686

2.  Reconstruction of crimes by infrared photography.

Authors:  V Sterzik; M Bohnert
Journal:  Int J Legal Med       Date:  2016-03-01       Impact factor: 2.686

3.  Detection of painted-over traces of blood and seminal fluid.

Authors:  V Barrera; C Haas; E A Meixner; B Fliss
Journal:  Int J Legal Med       Date:  2018-01-27       Impact factor: 2.686

Review 4.  On the Identification of Body Fluids and Tissues: A Crucial Link in the Investigation and Solution of Crime.

Authors:  Titia Sijen; SallyAnn Harbison
Journal:  Genes (Basel)       Date:  2021-10-28       Impact factor: 4.096

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.