The presumptive reagent fluorescein for detection of dilute bloodstains and subsequent STR typing of recovered DNA.

B Budowle1, J L Leggitt, D A Defenbaugh, K M Keys, S F Malkiewicz.   

Abstract

A presumptive reagent for dilute blood detection other than luminol is fluorescein. The sensitivity of fluorescein approaches the sensitivity of detection levels of luminol. The fluorescein detection method offers the advantages of working in a lighted environment, and the reaction persists longer than luminol. A series of diluted bloodstains, ranging from neat to 1:1,000,000, was placed on a variety of substrates. Three sets were made per substrate. One set was exposed to fluorescein, one set was exposed to luminol, and one set served as an uncontaminated control. The fluorescein signal persisted longer than luminol. However, background staining for fluorescein was observed on some substrates within 30 s to 1 min, and no background staining was observed for luminol. Stains on non-absorbent surfaces were detectable at 1:100,000 dilutions, and stains on absorbent surfaces were detectable usually at no more than 1:100. The sensitivity of detection of fluorescein was comparable to that of luminol in this study. In all cases, where sufficient DNA was recovered, typeable results at all 13 core CODIS STR loci were obtained from treated bloodstains and controls. The results from STR typing indicate that there was no evidence of DNA degradation.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11005186

Source DB:  PubMed          Journal:  J Forensic Sci        ISSN: 0022-1198            Impact factor:   1.832


  3 in total

Review 1.  Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses.

Authors:  Parvez Khan; Danish Idrees; Michael A Moxley; John A Corbett; Faizan Ahmad; Guido von Figura; William S Sly; Abdul Waheed; Md Imtaiyaz Hassan
Journal:  Appl Biochem Biotechnol       Date:  2014-04-22       Impact factor: 2.926

2.  Evaluation of the Effects of Different Sample Collection Strategies on DNA/RNA Co-Analysis of Forensic Stains.

Authors:  Daniela Lacerenza; Giorgio Caudullo; Elena Chierto; Serena Aneli; Giancarlo Di Vella; Marco Barberis; Samuele Voyron; Paola Berchialla; Carlo Robino
Journal:  Genes (Basel)       Date:  2022-05-30       Impact factor: 4.141

3.  An evaluation of luminol formulations and their effect on DNA profiling.

Authors:  Gnyaneshwari Patel; Andy Hopwood
Journal:  Int J Legal Med       Date:  2012-12-21       Impact factor: 2.686

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.